Literature DB >> 10379978

Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study.

E F Barrick1, J W O'Mara, H E Lane.   

Abstract

Procedures were performed to evaluate the efficacy of using a computer-assisted image-guided system to improve the accuracy of inserting iliosacral screws for posterior pelvic ring injuries. The fluoroscopic method currently in use has shortcomings that do not eliminate the risk to the L5 and sacral nerve roots and iliac vessels. The procedure was performed on embalmed cadaver pelvis specimens with intact soft tissues. Iliosacral screws were inserted across each sacroiliac joint after registering the opposite ilium to simulate a clinical situation. Two trials were performed. The first was necessary to become familiar with the system and test the basic methods of registration. In the second trial, deficiencies were corrected by using spherical-headed fiducial screws for fiducials and a better reference frame clamp, and by better spacing of more fiducials. Results were evaluated by inlet and outlet X-ray views and dissection. All eight S-1 iliosacral 7.0-mm cannulated screws were entirely inside bone. Of the eight S-2 screws, five were inside bone, two infringed upon an S-1 foramen, and one had threads out of the sacral body anteriorly and intruding into an S-1 foramen. This system was felt to be effective and sufficiently safe to warrant clinical trials.

Mesh:

Year:  1998        PMID: 10379978     DOI: 10.1002/(SICI)1097-0150(1998)3:6<289::AID-IGS2>3.0.CO;2-6

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  8 in total

1.  [Computer-assisted arthrodesis of the sacroiliac joint].

Authors:  F Gebhard; M Sarkar; G Maier; L Kinzl; M Arand
Journal:  Unfallchirurg       Date:  2005-09       Impact factor: 1.000

Review 2.  [Technique for percutaneous iliosacral screw insertion with conventional C-arm radiography].

Authors:  R E Hilgert; J Finn; H-J Egbers
Journal:  Unfallchirurg       Date:  2005-11       Impact factor: 1.000

3.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

4.  [A-mode ultrasonic pointer for navigated pelvic surgery].

Authors:  M Oszwald; M Citak; J Kowal; C Amstutz; D Kendoff; T Kirchhoff; L P Nolte; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-03       Impact factor: 1.000

5.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

6.  Planning, guidance, and quality assurance of pelvic screw placement using deformable image registration.

Authors:  J Goerres; A Uneri; M Jacobson; B Ramsay; T De Silva; M Ketcha; R Han; A Manbachi; S Vogt; G Kleinszig; J-P Wolinsky; G Osgood; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

7.  Deformable 3D-2D Registration for Guiding K-Wire Placement in Pelvic Trauma Surgery.

Authors:  J Goerres; M Jacobson; A Uneri; T De Silva; M Ketcha; S Reaungamornrat; S Vogt; G Kleinszig; J-P Wolinsky; G Osgood; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03

8.  A simple approach for the preoperative assessment of sacral morphology for percutaneous SI screw fixation.

Authors:  Michael Goetzen; Kevin Ortner; Richard A Lindtner; Rene Schmid; Michael Blauth; Dietmar Krappinger
Journal:  Arch Orthop Trauma Surg       Date:  2016-08-06       Impact factor: 3.067

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.