Comparison of the microbial load of incoming and distal outlet waters from dental unit water systems in Istanbul.

Irfan Türetgen1, Duygu Göksay, Aysin Cotuk.   

Abstract

This is a cross-sectional study of the incoming and distal outlet water quality from 41 dental units in Istanbul, carried out to compare the total microbial loads using traditional culture method versus epifluorescence microscopy. The possible presence of Legionella pneumophila using traditional culture method was also analyzed. One hundred and twenty three samples were taken from the high-speed handpiece lines, air-water syringe lines and source (incoming) water supplies from 41 dental units. The samples were assayed for live/dead bacteria, heterotrophic bacterial counts and presence of L. pneumophila bacteria. Thirty nine out of 41 dental units (91%) were not able to meet the standard limit of 200 CFU/ml in dental unit waters. The live bacterial counts were 1-1.5 orders of magnitude higher than aerobic mesophilic heterotrophic bacteria. L. pneumophila (serogroup 2-14) was isolated from five out of 41 units. Some dental units were using commercially bottled (19 l) drinking water as a source. The source water of eight dental unit was heavily contaminated which were fed up by commercially bottled drinking water.

Entities:  

Mesh:

Year:  2008        PMID: 18843542     DOI: 10.1007/s10661-008-0560-7

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  25 in total

Review 1.  Bacterial viability and culturability.

Authors:  M R Barer; C R Harwood
Journal:  Adv Microb Physiol       Date:  1999       Impact factor: 3.517

2.  Evaluation of the efficacy of Alpron disinfectant for dental unit water lines.

Authors:  A J Smith; S McHugh; I Aitken; J Hood
Journal:  Br Dent J       Date:  2002-11-23       Impact factor: 1.626

3.  Microbial contamination of dental unit waterlines in Istanbul, Turkey.

Authors:  Duygu Göksay; Ayşin Cotuk; Zuhal Zeybek
Journal:  Environ Monit Assess       Date:  2008-01-22       Impact factor: 2.513

Review 4.  Microbial biofilm formation in DUWS and their control using disinfectants.

Authors:  J T Walker; P D Marsh
Journal:  J Dent       Date:  2007-08-21       Impact factor: 4.379

5.  The source, frequency and extent of bacterial contamination of dental unit water systems.

Authors:  E J Fitzgibbon; C A Bartzokas; M V Martin; M F Gibson; R Graham
Journal:  Br Dent J       Date:  1984-08-11       Impact factor: 1.626

6.  Optimisation of the long-term efficacy of dental chair waterline disinfection by the identification and rectification of factors associated with waterline disinfection failure.

Authors:  M J O'Donnell; A C Shore; R J Russell; D C Coleman
Journal:  J Dent       Date:  2007-02-15       Impact factor: 4.379

Review 7.  The role of manufacturers in reducing biofilms in dental chair waterlines.

Authors:  D C Coleman; M J O'Donnell; A C Shore; J Swan; R J Russell
Journal:  J Dent       Date:  2007-06-18       Impact factor: 4.379

Review 8.  Drinking water microbiology--new directions toward water quality enhancement.

Authors:  E E Geldreich
Journal:  Int J Food Microbiol       Date:  1989-12       Impact factor: 5.277

9.  Microbiological evaluation of dental unit water systems in general dental practice in Europe.

Authors:  J T Walker; D J Bradshaw; M Finney; M R Fulford; E Frandsen; E ØStergaard; J M Ten Cate; W R Moorer; A J Schel; A Mavridou; J J Kamma; G Mandilara; L Stösser; S Kneist; R Araujo; N Contreras; P Goroncy-Bermes; D O'Mullane; F Burke; A Forde; M O'Sullivan; P D Marsh
Journal:  Eur J Oral Sci       Date:  2004-10       Impact factor: 2.612

10.  Prevalence of legionella waterline contamination and Legionella pneumophila antibodies in general dental practitioners in London and rural Northern Ireland.

Authors:  C L Pankhurst; W Coulter; J J Philpott-Howard; T Harrison; F Warburton; S Platt; S Surman; S Challacombe
Journal:  Br Dent J       Date:  2003-11-22       Impact factor: 1.626

View more
  11 in total

1.  Evaluation of microbial contamination and distribution of sulphate-reducing bacteria in dental units.

Authors:  Nihal Dogruöz; Esra Ilhan-Sungur; Duygu Göksay; Irfan Türetgen
Journal:  Environ Monit Assess       Date:  2011-03-08       Impact factor: 2.513

2.  Appraisal of microbial contamination of dental unit water systems and practices of general dental practitioners for risk reduction.

Authors:  Bajrang Lal; Khaiwal Ravindra; Manisha Biswal
Journal:  Environ Sci Pollut Res Int       Date:  2018-09-29       Impact factor: 4.223

3.  Microbial contamination of dental unit waterlines and effect on quality of indoor air.

Authors:  Duygu Göksay Kadaifciler; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2014-01-28       Impact factor: 2.513

4.  Bacterial contamination of dental unit waterlines.

Authors:  Jolanta Szymańska; Jolanta Sitkowska
Journal:  Environ Monit Assess       Date:  2012-08-17       Impact factor: 2.513

5.  Investigation of the bacterial load and antibiotic susceptibility of dental units.

Authors:  Nihal Dogruöz Güngör; Duygu Göksay Kadaifçiler; Oya Öztan Peker
Journal:  Environ Monit Assess       Date:  2013-11-06       Impact factor: 2.513

6.  Occurrence and biofilm forming ability of Pseudomonas aeruginosa in the water output of dental unit waterlines in a dental center in Alexandria, Egypt.

Authors:  Sheref Gawish; Aleya Abbass; Amani Abaza
Journal:  Germs       Date:  2019-06-03

7.  Evaluation of bacterial contamination of dental unit waterlines and use of a newly designed measurement device to assess retraction of a dental chair unit.

Authors:  Xue-Yue Ji; Chun-Nan Fei; Ying Zhang; Wei Zhang; Jun Liu; Jie Dong
Journal:  Int Dent J       Date:  2016-03-21       Impact factor: 2.607

8.  Three key factors influencing the bacterial contamination of dental unit waterlines: a 6-year survey from 2012 to 2017.

Authors:  Xue-Yue Ji; Chun-Nan Fei; Ying Zhang; Jun Liu; He Liu; Jia Song
Journal:  Int Dent J       Date:  2018-12-19       Impact factor: 2.607

Review 9.  Prevalence of Legionella Species in Water Resources of Iran: A Systematic Review and Meta-Analysis.

Authors:  Azad Khaledi; Afsane Bahrami; Edris Nabizadeh; Yousef Amini; Davoud Esmaeili
Journal:  Iran J Med Sci       Date:  2018-11

10.  Mycological contamination in dental unit waterlines in Istanbul, Turkey.

Authors:  Duygu Göksay Kadaifciler; Suzan Ökten; Burhan Sen
Journal:  Braz J Microbiol       Date:  2014-01-15       Impact factor: 2.476

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.