Literature DB >> 17576035

The role of manufacturers in reducing biofilms in dental chair waterlines.

D C Coleman1, M J O'Donnell, A C Shore, J Swan, R J Russell.   

Abstract

OBJECTIVES: This paper reviews how dental chair unit (DCU) manufacturers can contribute practically to resolving the problem of biofilm formation in dental unit waterlines (DUWs). STUDY SELECTION: The review concentrates on how novel developments and changes in a range of specific areas have, and might contribute to DUW biofilm control. These include (i) DCU engineering and design changes; (ii) improvements to DCU supply water quality; (iii) development of automated DUW treatment procedures that are effective at controlling biofilm in the long-term, safe for patients and dental staff, environmentally friendly and which do not exhibit adverse effects on DCU components after prolonged use. SOURCES: The majority of the material contained in this review is based on, or supported by the peer-reviewed literature. DATA: The current consensus from the literature reveals that the emphasis on DUW biofilm and its control has focused on describing the problem and its control using a range of periodic and residual DUW treatment agents. Unfortunately, until recently, DCU manufacturers have provided very little specific guidance in this regard. Indeed, ensuring that DCUs provide good quality output water has generally been regarded to be the responsibility of dental practitioners. Some recent studies have shown that novel DCUs with integral semi-automated or automated DUW cleaning systems can effectively control DUW biofilm in the long-term. However, there are other potential DCU engineering and design changes that DCU manufacturers could undertake to further improve DUW biofilm control.
CONCLUSIONS: DCU manufacturers can significantly contribute to controlling the problem of DUW biofilm.

Entities:  

Mesh:

Year:  2007        PMID: 17576035     DOI: 10.1016/j.jdent.2007.05.003

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  15 in total

1.  Comparison of the microbial load of incoming and distal outlet waters from dental unit water systems in Istanbul.

Authors:  Irfan Türetgen; Duygu Göksay; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2008-10-09       Impact factor: 2.513

2.  Pseudomonas aeruginosa and Achromobacter sp. clonal selection leads to successive waves of contamination of water in dental care units.

Authors:  Fatima Abdouchakour; Chloé Dupont; Delphine Grau; Fabien Aujoulat; Patricia Mournetas; Hélène Marchandin; Sylvie Parer; Philippe Gibert; Jean Valcarcel; Estelle Jumas-Bilak
Journal:  Appl Environ Microbiol       Date:  2015-08-21       Impact factor: 4.792

3.  Microbial contamination of dental unit waterlines and effect on quality of indoor air.

Authors:  Duygu Göksay Kadaifciler; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2014-01-28       Impact factor: 2.513

Review 4.  Monitoring dental-unit-water-line output water by current in-office test kits.

Authors:  Sham Lal; Sim K Singhrao; Matt Bricknell; Mark Pearce; L H Glyn Morton; Waqar Ahmed; St John Crean
Journal:  Curr Microbiol       Date:  2014-03-25       Impact factor: 2.188

Review 5.  Dental unit wastewater, a current environmental problem: a sistematic review.

Authors:  M E Cataldi; S Al Rakayan; C Arcuri; R Condò
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

Review 6.  Outbreaks of healthcare-associated infections linked to water-containing hospital equipment: a literature review.

Authors:  Wing-Kee Yiek; Olga Coenen; Mayke Nillesen; Jakko van Ingen; Edmée Bowles; Alma Tostmann
Journal:  Antimicrob Resist Infect Control       Date:  2021-05-10       Impact factor: 4.887

7.  Economic comparison of conventional maintenance and electrochemical oxidation to warrant water safety in dental unit water lines.

Authors:  Sebastian Fischer; Georg Meyer; Axel Kramer
Journal:  GMS Krankenhhyg Interdiszip       Date:  2012-04-04

8.  Three key factors influencing the bacterial contamination of dental unit waterlines: a 6-year survey from 2012 to 2017.

Authors:  Xue-Yue Ji; Chun-Nan Fei; Ying Zhang; Jun Liu; He Liu; Jia Song
Journal:  Int Dent J       Date:  2018-12-19       Impact factor: 2.607

9.  Impact of a risk management plan on Legionella contamination of dental unit water.

Authors:  Erica Leoni; Laura Dallolio; Francesca Stagni; Tiziana Sanna; Giovanni D'Alessandro; Gabriela Piana
Journal:  Int J Environ Res Public Health       Date:  2015-02-23       Impact factor: 3.390

10.  Distinct Microbial Community of Accumulated Biofilm in Dental Unit Waterlines of Different Specialties.

Authors:  Cancan Fan; Haijing Gu; Limin Liu; Haiwei Zhu; Juan Yan; Yongbiao Huo
Journal:  Front Cell Infect Microbiol       Date:  2021-06-17       Impact factor: 5.293

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.