Literature DB >> 21384117

Evaluation of microbial contamination and distribution of sulphate-reducing bacteria in dental units.

Nihal Dogruöz1, Esra Ilhan-Sungur, Duygu Göksay, Irfan Türetgen.   

Abstract

Although bacterial contamination is widely researched in dental unit water systems, we have been unable to find any published reports to date about the presence and distribution of sulphate-reducing bacteria (SRB) in dental unit waterlines (DUWLs). The aim of this study was to evaluate microbial contamination and to determine the presence and distribution of SRB in DUWLs. One hundred twenty-three water samples were collected from the air-water syringes, high-speed drills and water sources from 41 dental units in Istanbul, Turkey. The counts of aerobic heterotrophic bacteria and SRB were investigated in the water samples. In addition, the presence of free-living amoebae (FLA) was examined. In this work, we evaluated microbial contamination and reported for the first time the distribution of SRB in DUWLs. We determined that only ten out of 123 water samples were able to meet the American Dental Association's limit (≤200 CFU ml( - 1)). SRB were observed in 102 out of 123 samples (82.9%). In addition, SRB were detected in all of the air-water syringes and high-speed drills. FLA were established in 103 out of 123 samples (83.7%).

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21384117     DOI: 10.1007/s10661-011-1952-7

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  29 in total

1.  Microbial biofilm formation and contamination of dental-unit water systems in general dental practice.

Authors:  J T Walker; D J Bradshaw; A M Bennett; M R Fulford; M V Martin; P D Marsh
Journal:  Appl Environ Microbiol       Date:  2000-08       Impact factor: 4.792

2.  Evaluation of the efficacy of Alpron disinfectant for dental unit water lines.

Authors:  A J Smith; S McHugh; I Aitken; J Hood
Journal:  Br Dent J       Date:  2002-11-23       Impact factor: 1.626

3.  [Environmental monitoring of infective risks in Italian dental offices].

Authors:  S Monarca; M Grottolo; D Feretti; P Gigola; I Zerbini; A Alberti; C Zani; P L Sapelli
Journal:  Minerva Stomatol       Date:  2002 Jul-Aug

4.  Characterization of sulfate reducing bacteria isolated from cooling towers.

Authors:  Esra Ilhan Sungur; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2005-05       Impact factor: 2.513

5.  Microbial contamination of dental unit waterlines in Istanbul, Turkey.

Authors:  Duygu Göksay; Ayşin Cotuk; Zuhal Zeybek
Journal:  Environ Monit Assess       Date:  2008-01-22       Impact factor: 2.513

Review 6.  Microbial etiological agents of destructive periodontal diseases.

Authors:  A D Haffajee; S S Socransky
Journal:  Periodontol 2000       Date:  1994-06       Impact factor: 7.589

Review 7.  Microbes in dental unit water.

Authors:  C H Miller
Journal:  J Calif Dent Assoc       Date:  1996-01

8.  Probable new species of Desulfovibrio isolated from a pyogenic liver abscess.

Authors:  W Tee; M Dyall-Smith; W Woods; D Eisen
Journal:  J Clin Microbiol       Date:  1996-07       Impact factor: 5.948

9.  Vibrio cholerae O1 strains are facultative intracellular bacteria, able to survive and multiply symbiotically inside the aquatic free-living amoeba Acanthamoeba castellanii.

Authors:  Hadi Abd; Amir Saeed; Andrej Weintraub; G Balakrish Nair; Gunnar Sandström
Journal:  FEMS Microbiol Ecol       Date:  2007-04       Impact factor: 4.194

10.  Bacterial contamination of the water supply in newly installed dental units.

Authors:  H N Williams; A Johnson; J I Kelley; M L Baer; T S King; B Mitchell; J F Hasler
Journal:  Quintessence Int       Date:  1995-05       Impact factor: 1.677

View more
  1 in total

1.  Mycological contamination in dental unit waterlines in Istanbul, Turkey.

Authors:  Duygu Göksay Kadaifciler; Suzan Ökten; Burhan Sen
Journal:  Braz J Microbiol       Date:  2014-01-15       Impact factor: 2.476

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.