Literature DB >> 24197558

Investigation of the bacterial load and antibiotic susceptibility of dental units.

Nihal Dogruöz Güngör1, Duygu Göksay Kadaifçiler, Oya Öztan Peker.   

Abstract

The aim of this study was to evaluate the bacterial contamination level and to determine the antibiotic susceptibility of the isolated bacteria from dental unit waterlines (DUWLs) in Istanbul. Bacterial quality of DUWLs is very important, as patients and dental staff are regularly exposed to water and aerosols generated by the unit. If opportunistic pathogens such as Staphylococcus aureus, Pseudomonas aeruginosa, and Legionella pneumophila are present in DUWLs, patient and dental staff can be infected. One hundred water samples were collected from high-speed drills and input waters from 50 dental units. Aerobic heterotrophic bacteria counts and the presence of Legionella, Pseudomonas, oral streptococci, and Staphylococcus were investigated in dental unit waters and aerosol samples. In addition, the antibiotic susceptibility of the isolated and identified bacteria from DUWLs was examined. This research found that 37 out of 50 dental unit water samples exceeded the American Dental Association's limit of 200 colony-forming units (CFU)/mL(-1). Legionella, oral streptococci, and S. aureus were not detected in any water or aerosol samples, but P. aeruginosa was isolated in three DUWLs. Also, Pseudomonas and Staphylococcus were found in water and aerosol samples. Cefoperazone, ofloxacin, gentamicin, ciprofloxacin, and piperacillin were the most effective antibiotics against the isolated bacteria from DUWLs.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24197558     DOI: 10.1007/s10661-013-3498-3

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  30 in total

1.  Microbial biofilm formation and contamination of dental-unit water systems in general dental practice.

Authors:  J T Walker; D J Bradshaw; A M Bennett; M R Fulford; M V Martin; P D Marsh
Journal:  Appl Environ Microbiol       Date:  2000-08       Impact factor: 4.792

2.  [Environmental monitoring of infective risks in Italian dental offices].

Authors:  S Monarca; M Grottolo; D Feretti; P Gigola; I Zerbini; A Alberti; C Zani; P L Sapelli
Journal:  Minerva Stomatol       Date:  2002 Jul-Aug

3.  The presence of Pseudomonas aeruginosa in the dental unit waterline systems of teaching clinics.

Authors:  A S Al-Hiyasat; S Y Ma'ayeh; M Y Hindiyeh; Y S Khader
Journal:  Int J Dent Hyg       Date:  2007-02       Impact factor: 2.477

4.  Microbial contamination of dental unit waterlines in Istanbul, Turkey.

Authors:  Duygu Göksay; Ayşin Cotuk; Zuhal Zeybek
Journal:  Environ Monit Assess       Date:  2008-01-22       Impact factor: 2.513

Review 5.  The physiological activity of bacteria attached to solid surfaces.

Authors:  M Fletcher
Journal:  Adv Microb Physiol       Date:  1991       Impact factor: 3.517

Review 6.  The chemical control of biofouling in industrial water systems.

Authors:  T E Cloete; L Jacobs; V S Brözel
Journal:  Biodegradation       Date:  1998       Impact factor: 3.909

Review 7.  The environmental risk factors associated with medical and dental equipment in the transmission of Burkholderia (Pseudomonas) cepacia in cystic fibrosis patients.

Authors:  C L Pankhurst; J Philpott-Howard
Journal:  J Hosp Infect       Date:  1996-04       Impact factor: 3.926

8.  Bacterial contamination of dental chair units in a modern dental hospital caused by leakage from suction system hoses containing extensive biofilm.

Authors:  M J O'Donnell; C M Tuttlebee; F R Falkiner; D C Coleman
Journal:  J Hosp Infect       Date:  2005-04       Impact factor: 3.926

9.  Analysis of Legionella pneumophila serogroup 6 strains isolated from a hospital warm water supply over a three-year period by using genomic long-range mapping techniques and monoclonal antibodies.

Authors:  P C Lück; L Bender; M Ott; J H Helbig; J Hacker
Journal:  Appl Environ Microbiol       Date:  1991-11       Impact factor: 4.792

10.  Serological examinations for antibodies against Legionella species in dental personnel.

Authors:  F F Reinthaler; F Mascher; D Stünzner
Journal:  J Dent Res       Date:  1988-06       Impact factor: 6.116

View more
  7 in total

1.  Microbial contamination of dental unit waterlines and effect on quality of indoor air.

Authors:  Duygu Göksay Kadaifciler; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2014-01-28       Impact factor: 2.513

2.  Occurrence and biofilm forming ability of Pseudomonas aeruginosa in the water output of dental unit waterlines in a dental center in Alexandria, Egypt.

Authors:  Sheref Gawish; Aleya Abbass; Amani Abaza
Journal:  Germs       Date:  2019-06-03

3.  Occupational risk for Legionella infection among dental healthcare workers: meta-analysis in occupational epidemiology.

Authors:  Stefano Petti; Matteo Vitali
Journal:  BMJ Open       Date:  2017-07-13       Impact factor: 2.692

4.  Evaluation of Hydrogen Peroxide and Cetylpyridinium Chloride as Bacterial Decontaminants of Dental Unit Water Lines at a Private Peruvian Dental School.

Authors:  Arnaldo Munive-Degregori; Frank Mayta-Tovalino; Walter Gallo; Silvia Luza; Franco Mauricio; Saul Ilizarbe; Arnaldo Munive-Méndez
Journal:  J Int Soc Prev Community Dent       Date:  2020-11-24

5.  Dental unit water content and antibiotic resistance of Pseudomonas aeruginosa and Pseudomonas species: a case study.

Authors:  M Tesauro; M Consonni; I Grappasonni; G Lodi; R Mattina
Journal:  J Oral Microbiol       Date:  2022-08-23       Impact factor: 5.833

6.  Distinct Microbial Community of Accumulated Biofilm in Dental Unit Waterlines of Different Specialties.

Authors:  Cancan Fan; Haijing Gu; Limin Liu; Haiwei Zhu; Juan Yan; Yongbiao Huo
Journal:  Front Cell Infect Microbiol       Date:  2021-06-17       Impact factor: 5.293

7.  Suction Hoses of Dental Units as a Potential Source of Microbial Contamination.

Authors:  Tayebeh Zeinali; Elham Bozorgvar; Moghgan Habibi; Narjes Akbari; Behnam Barikbin
Journal:  Oman Med J       Date:  2020-03-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.