BACKGROUND: The contaminated output water from dental unit waterlines (DUWLs) is a potential risk to both patients and dental personnel who are frequently exposed to this water or aerosols. AIM: The purpose was to evaluate the contamination level and prevalence of bacteria in the output water of DUWLs, and to identify key factors to provide technical support for formulating relevant policies.
METHODS: We developed a special sampling connector designed for collecting dental handpiece output water and a measurement device to assess retraction of a dental chair unit (DCU). Output water from dental handpieces and air/water syringes were collected as representative of DUWLs. Water samples were tested with reference to China's national standard.
FINDINGS: From 2012 to 2017, 318 DCUs were randomly selected from 64 hospitals in Tianjin, China. Of these DCUs, 78.93% had no disinfection to prevent DUWL contamination. Three-hundred and forty-three (56.14%) samples complied with the guidelines on DUWL output water. The highest concentration of bacteria was 1.8 × 106  colony-forming units (CFUs)/mL. The three key factors of influence were as follows: daily or weekly disinfection of DUWLs; water supply source being hospital self-made purified water or purchased purified bottled water; and DCU with a valid anti-retraction valve. Potential infectious agents, including Bacillus cereus, Burkholderia cepacia and Pseudomonas aeruginosa, were isolated.
CONCLUSION: There was a high rate of contamination in DUWLs. This highlights the need to develop national standards. There is a need to disinfect the DUWLs periodically and use a cleaner source of water; more attention should be paid to the efficacy of DCU anti-retraction valves.
© 2018 FDI World Dental Federation.

Entities:  

Keywords:  Dental unit waterlines; air/water syringe; bacteria; dental handpiece; retraction; water microbiology

Mesh:

Year:  2018        PMID: 30565215      PMCID: PMC9379084          DOI: 10.1111/idj.12456

Source DB:  PubMed          Journal:  Int Dent J        ISSN: 0020-6539            Impact factor:   2.607


  42 in total

1.  SPREAD OF ORGANISMS FROM DENTAL AIR ROTOR.

Authors:  C M BELTING; G C HABERFELDE; L K JUHL
Journal:  J Am Dent Assoc       Date:  1964-05       Impact factor: 3.634

Review 2.  Management of dental unit waterline biofilms in the 21st century.

Authors:  Mary J O'Donnell; Maria A Boyle; Ronnie J Russell; David C Coleman
Journal:  Future Microbiol       Date:  2011-10       Impact factor: 3.165

3.  Multistate Modeling to Analyze Nosocomial Infection Data: An Introduction and Demonstration.

Authors:  Martin Wolkewitz; Maja von Cube; Martin Schumacher
Journal:  Infect Control Hosp Epidemiol       Date:  2017-06-21       Impact factor: 3.254

4.  Failure of anti-retraction valves and the procedure for between patient flushing: a rationale for chemical control of dental unit waterline contamination.

Authors:  Lucio Montebugnoli; Giovanni Dolci; David Alexander Spratt; Raghunath Puttaiah
Journal:  Am J Dent       Date:  2005-08       Impact factor: 1.522

5.  The presence of Pseudomonas aeruginosa in the dental unit waterline systems of teaching clinics.

Authors:  A S Al-Hiyasat; S Y Ma'ayeh; M Y Hindiyeh; Y S Khader
Journal:  Int J Dent Hyg       Date:  2007-02       Impact factor: 2.477

Review 6.  Biofilm and the dental office.

Authors:  B G Shearer
Journal:  J Am Dent Assoc       Date:  1996-02       Impact factor: 3.634

7.  Legionellosis acquired through a dental unit: a case study.

Authors:  C Schönning; C Jernberg; D Klingenberg; S Andersson; A Pääjärvi; E Alm; E Tano; B Lytsy
Journal:  J Hosp Infect       Date:  2017-01-20       Impact factor: 3.926

8.  Influence of material and tube size on DUWLs contamination in a pilot plant.

Authors:  Rossella Sacchetti; Giovanna De Luca; Franca Zanetti
Journal:  New Microbiol       Date:  2007-01       Impact factor: 2.479

9.  Microbial contamination of dental unit waterlines in dental practices in Hesse, Germany: A cross-sectional study.

Authors:  Mardjan Arvand; Alfons Hack
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2013-03-13

10.  Impact of a risk management plan on Legionella contamination of dental unit water.

Authors:  Erica Leoni; Laura Dallolio; Francesca Stagni; Tiziana Sanna; Giovanni D'Alessandro; Gabriela Piana
Journal:  Int J Environ Res Public Health       Date:  2015-02-23       Impact factor: 3.390

View more
  7 in total

1.  Chlorine-based DUWL disinfectant leads to a different microbial composition of water derived biofilms compared to H2O2-based chemical disinfectants in vitro.

Authors:  Charifa Zemouri; Alexa M G A Laheij; Catherine M C Volgenant; Bernd W Brandt; Wim Crielaard; Mark J Buijs; Egija Zaura; Johannes J de Soet
Journal:  PeerJ       Date:  2020-07-15       Impact factor: 2.984

2.  Prevention and Control of Legionella and Pseudomonas spp. Colonization in Dental Units.

Authors:  Benedetta Tuvo; Michele Totaro; Maria Luisa Cristina; Anna Maria Spagnolo; David Di Cave; Sara Profeti; Angelo Baggiani; Gaetano Privitera; Beatrice Casini
Journal:  Pathogens       Date:  2020-04-21

3.  Evaluation of Hydrogen Peroxide and Cetylpyridinium Chloride as Bacterial Decontaminants of Dental Unit Water Lines at a Private Peruvian Dental School.

Authors:  Arnaldo Munive-Degregori; Frank Mayta-Tovalino; Walter Gallo; Silvia Luza; Franco Mauricio; Saul Ilizarbe; Arnaldo Munive-Méndez
Journal:  J Int Soc Prev Community Dent       Date:  2020-11-24

4.  Assessment of microbiota diversity in dental unit waterline contamination.

Authors:  Yun Dang; Qian Zhang; Jing Wang; Qian Wang; Meng Han; Yuting Niu; Hua Li; Xiue Li
Journal:  PeerJ       Date:  2022-01-06       Impact factor: 3.061

5.  Distinct Microbial Community of Accumulated Biofilm in Dental Unit Waterlines of Different Specialties.

Authors:  Cancan Fan; Haijing Gu; Limin Liu; Haiwei Zhu; Juan Yan; Yongbiao Huo
Journal:  Front Cell Infect Microbiol       Date:  2021-06-17       Impact factor: 5.293

Review 6.  Dental care and personal protective measures for dentists and non-dental health care workers.

Authors:  Shankargouda Patil; Ibtisam Hussain Moafa; Shilpa Bhandi; Mohammed Abdurabu Jafer; Samar Saeed Khan; Shahrukh Khan; William B Carroll; Kamran Habib Awan
Journal:  Dis Mon       Date:  2020-07-30       Impact factor: 3.800

7.  Efficacy of BRS® and Alpron®/Bilpron® Disinfectants for Dental Unit Waterlines: A Six-Year Study.

Authors:  Alexandre Baudet; Julie Lizon; Jean-Marc Martrette; Frédéric Camelot; Arnaud Florentin; Céline Clément
Journal:  Int J Environ Res Public Health       Date:  2020-04-12       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.