Literature DB >> 18825425

A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images.

Shunji Hirokawa1, M Abrar Hossain, Yuichi Kihara, Shogo Ariyoshi.   

Abstract

In this paper, we propose three ideas to improve a kinematic estimation algorithm for total knee arthroplasty. The first is a two-step estimation algorithm that improves estimation accuracy by excluding certain assumptions needed for the pattern matching algorithm reported by Banks and Hodge. The second is incorporating a 3D geometric articulation model into the algorithm to improve estimation accuracy substantially for the depth translation, and to introduce contact points' trajectories between the articular surfaces. The third is an algorithm to process estimation even when the silhouettes of two components overlap. To assess our algorithm's potential for clinical application, we carried out two experiments. First, we used a robot to position the prosthesis. Estimation accuracy was checked by comparing input data to the robot with the estimates from X-ray photographs. Incorporating our articulation model remarkably reduced the error in the depth translation. Next, we performed a clinical assessment by applying the algorithm and articulation model to fluoroscopy images of a patient who had recently had TKA.

Entities:  

Mesh:

Year:  2008        PMID: 18825425     DOI: 10.1007/s11517-008-0398-8

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  14 in total

1.  A simple radiographic measurement method for polyethylene wear in total knee arthroplasty.

Authors:  Y Fukuoka; A Hoshino; A Ishida
Journal:  IEEE Trans Rehabil Eng       Date:  1999-06

2.  A model-based method for the reconstruction of total knee replacement kinematics.

Authors:  S Zuffi; A Leardini; F Catani; S Fantozzi; A Cappello
Journal:  IEEE Trans Med Imaging       Date:  1999-10       Impact factor: 10.048

3.  In vivo three-dimensional knee kinematics using a biplanar image-matching technique.

Authors:  T Asano; M Akagi; K Tanaka; J Tamura; T Nakamura
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

4.  Model-based Roentgen stereophotogrammetry of orthopaedic implants.

Authors:  E R Valstar; F W de Jong; H A Vrooman; P M Rozing; J H Reiber
Journal:  J Biomech       Date:  2001-06       Impact factor: 2.712

5.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

6.  Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy.

Authors:  Takaharu Yamazaki; Tetsu Watanabe; Yoshikazu Nakajima; Kazuomi Sugamoto; Tetsuya Tomita; Hideki Yoshikawa; Shinichi Tamura
Journal:  IEEE Trans Med Imaging       Date:  2004-05       Impact factor: 10.048

7.  Effect of segmentation errors on 3D-to-2D registration of implant models in X-ray images.

Authors:  Mohamed R Mahfouz; William A Hoff; Richard D Komistek; Douglas A Dennis
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

8.  Accuracy of pelvic flexion measurements from lateral radiographs.

Authors:  Kort Eckman; Mahmoud A Hafez; Frcs Ed; Branislav Jaramaz; Timothy J Levison; Anthony M Digioia
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

9.  A new method for distortion correction of electronic endoscope images.

Authors:  H Haneishi; Y Yagihashi; Y Miyake
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

10.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy.

Authors:  S A Banks; W A Hodge
Journal:  IEEE Trans Biomed Eng       Date:  1996-06       Impact factor: 4.538

View more
  5 in total

1.  Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

Authors:  Giacomo Tarroni; Luca Tersi; Cristiana Corsi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-03-27       Impact factor: 2.602

2.  Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy.

Authors:  Nora Baka; Bart L Kaptein; J Erik Giphart; Marius Staring; Marleen de Bruijne; Boudewijn P F Lelieveldt; Edward Valstar
Journal:  J Biomech       Date:  2013-10-09       Impact factor: 2.712

3.  In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

Authors:  Luca Tersi; Arnaud Barré; Silvia Fantozzi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-11-11       Impact factor: 2.602

4.  3D kinematics of mobile-bearing total knee arthroplasty using X-ray fluoroscopy.

Authors:  Takaharu Yamazaki; Kazuma Futai; Tetsuya Tomita; Yoshinobu Sato; Hideki Yoshikawa; Shinichi Tamura; Kazuomi Sugamoto
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-26       Impact factor: 2.924

5.  Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA).

Authors:  Chi-Pin Hsu; Shang-Chih Lin; Kao-Shang Shih; Chang-Hung Huang; Chian-Her Lee
Journal:  Med Biol Eng Comput       Date:  2014-10-08       Impact factor: 2.602

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.