Literature DB >> 23143478

In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

Luca Tersi1, Arnaud Barré, Silvia Fantozzi, Rita Stagni.   

Abstract

Model-based mono-planar and bi-planar 3D fluoroscopy methods can quantify intact joints kinematics with performance/cost trade-off. The aim of this study was to compare the performances of mono- and bi-planar setups to a marker-based gold-standard, during dynamic phantom knee acquisitions. Absolute pose errors for in-plane parameters were lower than 0.6 mm or 0.6° for both mono- and bi-planar setups. Mono-planar setups resulted critical in quantifying the out-of-plane translation (error < 6.5 mm), and bi-planar in quantifying the rotation along bone longitudinal axis (error < 1.3°). These errors propagated to joint angles and translations differently depending on the alignment of the anatomical axes and the fluoroscopic reference frames. Internal-external rotation was the least accurate angle both with mono- (error < 4.4°) and bi-planar (error < 1.7°) setups, due to bone longitudinal symmetries. Results highlighted that accuracy for mono-planar in-plane pose parameters is comparable to bi-planar, but with halved computational costs, halved segmentation time and halved ionizing radiation dose. Bi-planar analysis better compensated for the out-of-plane uncertainty that is differently propagated to relative kinematics depending on the setup. To take its full benefits, the motion task to be investigated should be designed to maintain the joint inside the visible volume introducing constraints with respect to mono-planar analysis.

Entities:  

Mesh:

Year:  2012        PMID: 23143478     DOI: 10.1007/s11517-012-0987-4

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  47 in total

1.  The precision of radiostereometric measurements. Manual vs. digital measurements.

Authors:  Niclas Börlin; Truike Thien; Johan Kärrholm
Journal:  J Biomech       Date:  2002-01       Impact factor: 2.712

2.  In vivo knee kinematics in patients with bilateral total knee arthroplasty of 2 designs.

Authors:  Nobukazu Okamoto; Leigh Breslauer; Anthony K Hedley; Hiroshi Mizuta; Scott A Banks
Journal:  J Arthroplasty       Date:  2010-09-25       Impact factor: 4.757

3.  Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjects.

Authors:  Rita Stagni; Silvia Fantozzi; Angelo Cappello; Alberto Leardini
Journal:  Clin Biomech (Bristol, Avon)       Date:  2005-03       Impact factor: 2.063

4.  Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics.

Authors:  Michael J Bey; Roger Zauel; Stephanie K Brock; Scott Tashman
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

5.  An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system.

Authors:  Jeffrey Bingham; Guoan Li
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

6.  Comparison of three standard anatomical reference frames for the tibia-fibula complex.

Authors:  Giorgia Conti; Luca Cristofolini; Mateusz Juszczyk; Alberto Leardini; Marco Viceconti
Journal:  J Biomech       Date:  2008-11-07       Impact factor: 2.712

7.  Effects of soft tissue artifacts on the calculated kinematics and kinetics of the knee during stair-ascent.

Authors:  Tsung-Yuan Tsai; Tung-Wu Lu; Mei-Ying Kuo; Cheng-Chung Lin
Journal:  J Biomech       Date:  2011-04-07       Impact factor: 2.712

8.  In vivo shoulder function after surgical repair of a torn rotator cuff: glenohumeral joint mechanics, shoulder strength, clinical outcomes, and their interaction.

Authors:  Michael J Bey; Cathryn D Peltz; Kristin Ciarelli; Stephanie K Kline; George W Divine; Marnix van Holsbeeck; Stephanie Muh; Patricia A Kolowich; Terrence R Lock; Vasilios Moutzouros
Journal:  Am J Sports Med       Date:  2011-07-07       Impact factor: 6.202

9.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee.

Authors:  E S Grood; W J Suntay
Journal:  J Biomech Eng       Date:  1983-05       Impact factor: 2.097

10.  Soft-tissue artefact assessment during step-up using fluoroscopy and skin-mounted markers.

Authors:  E H Garling; B L Kaptein; B Mertens; W Barendregt; H E J Veeger; R G H H Nelissen; E R Valstar
Journal:  J Biomech       Date:  2007-04-25       Impact factor: 2.712

View more
  4 in total

1.  Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy.

Authors:  Nora Baka; Bart L Kaptein; J Erik Giphart; Marius Staring; Marleen de Bruijne; Boudewijn P F Lelieveldt; Edward Valstar
Journal:  J Biomech       Date:  2013-10-09       Impact factor: 2.712

Review 2.  [Kinematic examination of the musculoskeletal system : Use of methods of image and image sequence analyses as well as shape and motion models].

Authors:  S Landgraeber; J Pauli
Journal:  Orthopade       Date:  2018-10       Impact factor: 1.087

3.  Gaussian mixture models based 2D-3D registration of bone shapes for orthopedic surgery planning.

Authors:  Marta Valenti; Giancarlo Ferrigno; Dario Martina; Weimin Yu; Guoyan Zheng; Mohsen Akbari Shandiz; Carolyn Anglin; Elena De Momi
Journal:  Med Biol Eng Comput       Date:  2016-03-23       Impact factor: 2.602

4.  Error performances of a model-based biplane fluoroscopic system for tracking knee prosthesis during treadmill gait task.

Authors:  Arnaud Barré; Kamiar Aminian
Journal:  Med Biol Eng Comput       Date:  2017-07-18       Impact factor: 2.602

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.