A new method for distortion correction of electronic endoscope images.

H Haneishi1, Y Yagihashi, Y Miyake.   

Abstract

A new method to correct the barrel distortion of an electronic endoscope image is presented. A correction model assuming circularly symmetric distortion is introduced with the following model parameters: the center of distortion and the coefficients of polynomials representing the distortion correction in the radial direction. If the imaging system is distortion-free, straight lines in the object space should be imaged as straight lines. Based on this criterion, a distorted image of a standard pattern consisting of a grid of several straight lines is recorded, and the model parameters are then estimated as a basis for straightening distorted lines. This method has the advantage of not needing a careful placement of the standard pattern for calibration. Correction results are presented for the grid pattern chart to verify a sufficient degree of correction. Examples of distortion correction of real intestinal images and physicians' comments are also presented.

Year:  1995        PMID: 18215859     DOI: 10.1109/42.414620

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

1.  Technique of distortion correction in endoscopic images using a polynomial expansion.

Authors:  K V Asari; S Kumar; D Radhakrishnan
Journal:  Med Biol Eng Comput       Date:  1999-01       Impact factor: 2.602

2.  Foveated endoscopic lens.

Authors:  Nathan Hagen; Tomasz S Tkaczyk
Journal:  J Biomed Opt       Date:  2012-02       Impact factor: 3.170

3.  Distortion, Orientation, and Translation Corrections of Tiled EMCCD Detectors for the New Solid State X-ray Image Intensifier (SSXII).

Authors:  Hidab Hamwi; Joseph W Lee; Kenneth R Hoffmann; Stephen Rudin; Aleksandr Verevkin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

4.  A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images.

Authors:  Shunji Hirokawa; M Abrar Hossain; Yuichi Kihara; Shogo Ariyoshi
Journal:  Med Biol Eng Comput       Date:  2008-09-30       Impact factor: 2.602

5.  3D kinematics of mobile-bearing total knee arthroplasty using X-ray fluoroscopy.

Authors:  Takaharu Yamazaki; Kazuma Futai; Tetsuya Tomita; Yoshinobu Sato; Hideki Yoshikawa; Shinichi Tamura; Kazuomi Sugamoto
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-26       Impact factor: 2.924

6.  Evaluation of different distortion correction methods and interpolation techniques for an automated classification of celiac disease.

Authors:  M Gadermayr; M Liedlgruber; A Uhl; A Vécsei
Journal:  Comput Methods Programs Biomed       Date:  2013-08-24       Impact factor: 5.428