Literature DB >> 25293422

Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA).

Chi-Pin Hsu1, Shang-Chih Lin, Kao-Shang Shih, Chang-Hung Huang, Chian-Her Lee.   

Abstract

After total knee replacement, the model-based Roentgen stereophotogrammetric analysis (RSA) technique has been used to monitor the status of prosthetic wear, misalignment, and even failure. However, the overlap of the prosthetic outlines inevitably increases errors in the estimation of prosthetic poses due to the limited amount of available outlines. In the literature, quite a few studies have investigated the problems induced by the overlapped outlines, and manual adjustment is still the mainstream. This study proposes two methods to automate the image processing of overlapped outlines prior to the pose registration of prosthetic models. The outline-separated method defines the intersected points and segments the overlapped outlines. The feature-recognized method uses the point and line features of the remaining outlines to initiate registration. Overlap percentage is defined as the ratio of overlapped to non-overlapped outlines. The simulated images with five overlapping percentages are used to evaluate the robustness and accuracy of the proposed methods. Compared with non-overlapped images, overlapped images reduce the number of outlines available for model-based RSA calculation. The maximum and root mean square errors for a prosthetic outline are 0.35 and 0.04 mm, respectively. The mean translation and rotation errors are 0.11 mm and 0.18°, respectively. The errors of the model-based RSA results are increased when the overlap percentage is beyond about 9%. In conclusion, both outline-separated and feature-recognized methods can be seamlessly integrated to automate the calculation of rough registration. This can significantly increase the clinical practicability of the model-based RSA technique.

Entities:  

Mesh:

Year:  2014        PMID: 25293422     DOI: 10.1007/s11517-014-1206-2

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  20 in total

1.  A simple radiographic measurement method for polyethylene wear in total knee arthroplasty.

Authors:  Y Fukuoka; A Hoshino; A Ishida
Journal:  IEEE Trans Rehabil Eng       Date:  1999-06

2.  Model-based Roentgen stereophotogrammetry of orthopaedic implants.

Authors:  E R Valstar; F W de Jong; H A Vrooman; P M Rozing; J H Reiber
Journal:  J Biomech       Date:  2001-06       Impact factor: 2.712

3.  Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy.

Authors:  Takaharu Yamazaki; Tetsu Watanabe; Yoshikazu Nakajima; Kazuomi Sugamoto; Tetsuya Tomita; Hideki Yoshikawa; Shinichi Tamura
Journal:  IEEE Trans Med Imaging       Date:  2004-05       Impact factor: 10.048

4.  Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis.

Authors:  B L Kaptein; E R Valstar; B C Stoel; P M Rozing; J H C Reiber
Journal:  Proc Inst Mech Eng H       Date:  2004       Impact factor: 1.617

Review 5.  Roentgen stereophotogrammetry. Review of orthopedic applications.

Authors:  J Kärrholm
Journal:  Acta Orthop Scand       Date:  1989-08

6.  An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system.

Authors:  Jeffrey Bingham; Guoan Li
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

7.  New registration algorithm for determining 3D knee kinematics using CT and single-plane fluoroscopy with improved out-of-plane translation accuracy.

Authors:  Jennifer M Scarvell; Mark R Pickering; Paul N Smith
Journal:  J Orthop Res       Date:  2010-03       Impact factor: 3.494

8.  A computational approach to edge detection.

Authors:  J Canny
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1986-06       Impact factor: 6.226

9.  Guidelines for standardization of radiostereometry (RSA) of implants.

Authors:  Edward R Valstar; Richie Gill; Leif Ryd; Gunnar Flivik; Niclas Börlin; Johan Kärrholm
Journal:  Acta Orthop       Date:  2005-08       Impact factor: 3.717

10.  Improvement in the clinical practicability of roentgen stereophotogrammetric analysis (RSA): free from the use of the dual X-ray equipment.

Authors:  Kao-Shang Shih; Chian-Her Lee; Ci-Bin Syu; Jiing-Yih Lai; Kuo-Jen Chen; Shang-Chih Lin
Journal:  Proc Inst Mech Eng H       Date:  2012-10       Impact factor: 1.617

View more
  2 in total

1.  Error performances of a model-based biplane fluoroscopic system for tracking knee prosthesis during treadmill gait task.

Authors:  Arnaud Barré; Kamiar Aminian
Journal:  Med Biol Eng Comput       Date:  2017-07-18       Impact factor: 2.602

2.  Verifying a C-arm-based roentgen stereophotogrammetric analysis protocol for assessing tibial implant movement in total knee arthroplasty.

Authors:  Vivian W J Chung; Robyn Newell; Angela Kedgley; Carolyn Anglin; Bassam A Masri; Antony J Hodgson
Journal:  Med Biol Eng Comput       Date:  2022-06-28       Impact factor: 3.079

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.