Literature DB >> 22450847

Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

Giacomo Tarroni1, Luca Tersi, Cristiana Corsi, Rita Stagni.   

Abstract

A new method for prosthetic component segmentation from fluoroscopic images is presented. The hybrid approach we propose combines diffusion filtering, region growing and level-set techniques without exploiting any a priori knowledge of the analyzed geometry. The method was evaluated on a synthetic dataset including 270 images of knee and hip prosthesis merged to real fluoroscopic data simulating different conditions of blurring and illumination gradient. The performance of the method was assessed by comparing estimated contours to references using different metrics. Results showed that the segmentation procedure is fast, accurate, independent on the operator as well as on the specific geometrical characteristics of the prosthetic component, and able to compensate for amount of blurring and illumination gradient. Importantly, the method allows a strong reduction of required user interaction time when compared to traditional segmentation techniques. Its effectiveness and robustness in different image conditions, together with simplicity and fast implementation, make this prosthetic component segmentation procedure promising and suitable for multiple clinical applications including assessment of in vivo joint kinematics in a variety of cases.

Mesh:

Year:  2012        PMID: 22450847     DOI: 10.1007/s11517-012-0884-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  20 in total

1.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

2.  Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy.

Authors:  Takaharu Yamazaki; Tetsu Watanabe; Yoshikazu Nakajima; Kazuomi Sugamoto; Tetsuya Tomita; Hideki Yoshikawa; Shinichi Tamura
Journal:  IEEE Trans Med Imaging       Date:  2004-05       Impact factor: 10.048

3.  Effect of segmentation errors on 3D-to-2D registration of implant models in X-ray images.

Authors:  Mohamed R Mahfouz; William A Hoff; Richard D Komistek; Douglas A Dennis
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

4.  In vivo medial and lateral tibial loads during dynamic and high flexion activities.

Authors:  Dong Zhao; Scott A Banks; Darryl D D'Lima; Clifford W Colwell; Benjamin J Fregly
Journal:  J Orthop Res       Date:  2007-05       Impact factor: 3.494

5.  Clinical validation of model-based RSA for a total knee prosthesis.

Authors:  Bart L Kaptein; Edward R Valstar; Berend C Stoel; Hans C Reiber; Rob G Nelissen
Journal:  Clin Orthop Relat Res       Date:  2007-11       Impact factor: 4.176

6.  Image sequence filtering in quantum-limited noise with applications to low-dose fluoroscopy.

Authors:  C L Chan; A K Katsaggelos; A V Sahakian
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

7.  A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images.

Authors:  Shunji Hirokawa; M Abrar Hossain; Yuichi Kihara; Shogo Ariyoshi
Journal:  Med Biol Eng Comput       Date:  2008-09-30       Impact factor: 2.602

8.  A no-reference image blur metric based on the cumulative probability of blur detection (CPBD).

Authors:  Niranjan D Narvekar; Lina J Karam
Journal:  IEEE Trans Image Process       Date:  2011-03-28       Impact factor: 10.856

9.  A computational approach to edge detection.

Authors:  J Canny
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1986-06       Impact factor: 6.226

10.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy.

Authors:  S A Banks; W A Hodge
Journal:  IEEE Trans Biomed Eng       Date:  1996-06       Impact factor: 4.538

View more
  1 in total

1.  Error performances of a model-based biplane fluoroscopic system for tracking knee prosthesis during treadmill gait task.

Authors:  Arnaud Barré; Kamiar Aminian
Journal:  Med Biol Eng Comput       Date:  2017-07-18       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.