Rotating platform versus fixed-bearing total knees: an in vitro study of wear.

Hani Haider1, Kevin Garvin.   

Abstract

One of the assumed benefits of mobile bearings is the reduction of UHMWPE wear. However, to date, such benefit has not been categorically proven. To test the hypothesis that rotating platform total knee arthroplasty would have less wear than a fixed-bearing of the same design, this in vitro study compared the wear and kinematics (which influence wear) of one type of mobile with fixed-bearing tibial components of otherwise identical design. We tested four fixed bearing (FB) and four rotating platforms (RP) on force control knee simulators using identical ISO standard force inputs and simulated soft tissue restraint for 6 million walking cycles. The internal/external rotations peaked just before toe off, reaching an average maximum of 7 degrees internal (tibial rotation) in the RP, 1.5 times that of the FB, which peaked at approximately 4.5 degrees internally. Two of the RP specimens showed infrequent and mostly temporary dislocations of the UHMWPE insert. The wear rate for the FB averaged 8.14 +/- 2.63 mg/million cycles and the RP averaged 6.78 +/- 1.74 mg/million cycles. Both were very low wear rates compared with most other implants tested similarly in the same laboratory. We concluded polyethylene wear was similar for both designs.

Entities:  

Mesh:

Year:  2008        PMID: 18758877      PMCID: PMC2565040          DOI: 10.1007/s11999-008-0463-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  31 in total

1.  An experimental model of tibial counterface polyethylene wear in mobile bearing knees: the influence of design and kinematics.

Authors:  V C Jones; D C Barton; D P Fitzpatrick; D D Auger; M H Stone; J Fisher
Journal:  Biomed Mater Eng       Date:  1999       Impact factor: 1.300

2.  The Genesis total knee prosthesis: a 10-year followup study.

Authors:  R S Laskin
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

3.  Twenty-year evaluation of meniscal bearing and rotating platform knee replacements.

Authors:  F F Buechel; F F Buechel; M J Pappas; J D'Alessio
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

4.  Long-term followup of anatomic graduated components posterior cruciate-retaining total knee replacement.

Authors:  M A Ritter; M E Berend; J B Meding; E M Keating; P M Faris; B M Crites
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

5.  Comparison of fixed-bearing and mobile-bearing total knee arthroplasties.

Authors:  Y H Kim; H K Kook; J S Kim
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

6.  Polyethylene contact stresses, articular congruity, and knee alignment.

Authors:  D D D'Lima; P C Chen; C W Colwell
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

7.  Total condylar knee arthroplasty. 16- to 21-year results.

Authors:  G S Gill; A B Joshi; D M Mills
Journal:  Clin Orthop Relat Res       Date:  1999-10       Impact factor: 4.176

8.  Total condylar knee arthroplasty: a long-term followup.

Authors:  V Pavone; F Boettner; S Fickert; T P Sculco
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

9.  Relative motion of a mobile bearing inlay after total knee arthroplasty--dynamic in vitro study.

Authors:  C Stukenborg-Colsman; S Ostermeier; K H Wenger; C J Wirth
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-01       Impact factor: 2.063

10.  Sterilization and wear-related failure in first- and second-generation press-fit condylar total knee arthroplasty.

Authors:  William L Griffin; Thomas K Fehring; Donald L Pomeroy; Thomas A Gruen; Jeffrey A Murphy
Journal:  Clin Orthop Relat Res       Date:  2007-11       Impact factor: 4.176

View more
  11 in total

1.  Mid-term results with a highly congruous mobile-bearing knee prosthesis.

Authors:  Roger G Lemaire
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-08-22       Impact factor: 4.342

Review 2.  Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis.

Authors:  Toby O Smith; Farshid Ejtehadi; Rachel Nichols; Leigh Davies; Simon T Donell; Caroline B Hing
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-25       Impact factor: 4.342

3.  No clinical difference between fixed- and mobile-bearing cruciate-retaining total knee arthroplasty: a prospective randomized study.

Authors:  O Bailey; K Ferguson; E Crawfurd; P James; P A May; S Brown; M Blyth; W J Leach
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-09       Impact factor: 4.342

Review 4.  No differences between fixed- and mobile-bearing total knee arthroplasty.

Authors:  B L Fransen; D C van Duijvenbode; M J M Hoozemans; B J Burger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-06-20       Impact factor: 4.342

Review 5.  Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers.

Authors:  D Baykal; R S Siskey; H Haider; V Saikko; T Ahlroos; S M Kurtz
Journal:  J Mech Behav Biomed Mater       Date:  2013-05-29

6.  NexGen® LPS mobile bearing total knee arthroplasty: 10-year results.

Authors:  Alessandro Bistolfi; Gwo-Chin Lee; Davide Deledda; Federica Rosso; Paola Berchialla; Maurizio Crova; Giuseppe Massazza
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-04-30       Impact factor: 4.342

7.  Dynamic finite element analysis of mobile bearing type knee prosthesis under deep flexional motion.

Authors:  Mohd Afzan Mohd Anuar; Mitsugu Todo; Ryuji Nagamine; Shunji Hirokawa
Journal:  ScientificWorldJournal       Date:  2014-07-17

8.  CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

Authors:  Jens Schwiesau; Bernhard Fritz; Ines Kutzner; Georg Bergmann; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2014-11-20       Impact factor: 3.411

9.  Increased risk of aseptic loosening for 43,525 rotating-platform vs. fixed-bearing total knee replacements.

Authors:  Oystein Gothesen; Stein Hakon L Lygre; Michelle Lorimer; Stephen Graves; Ove Furnes
Journal:  Acta Orthop       Date:  2017-09-20       Impact factor: 3.717

10.  Evaluation of 1031 primary titanium nitride coated mobile bearing total knee arthroplasties in an orthopedic clinic.

Authors:  Stefan J M Breugem; Jeroen Linnartz; Inger Sierevelt; Jon D Bruijn; Marcel J M Driessen
Journal:  World J Orthop       Date:  2017-12-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.