Literature DB >> 11716388

Polyethylene contact stresses, articular congruity, and knee alignment.

D D D'Lima1, P C Chen, C W Colwell.   

Abstract

Increased conformity at the tibiofemoral articulation increases contact area and reduces contact stresses in total knee arthroplasty. Malalignment, however, can increase polyethylene contact stresses. The effect of knee alignment and articular conformity on contact stresses was evaluated in a finite element model. The polyethylene insert and femoral component were modeled in high- and low-conformity conditions. An axial tibial load of 3000 N was applied across the tibiofemoral articulation at different knee positions ranging from 0 degrees, to 90 degrees, flexion, 0 to 10 mm anteroposterior translation, 0 degrees to 10 degrees axial rotation, and coronal plane angulation (liftoff). Increased conformity significantly reduced contact stresses in neutral alignment (by 44% at 0 degrees flexion and 36% at 60 degrees and 90 degrees flexion). Liftoff significantly increased contact stresses in low- and high-conformity conditions, but to a lesser degree in the high-conformity condition. Malalignment in rotation was most detrimental especially with the high-conformity insert design. Overall, increasing articular conformity reduced stresses when the knee was well-aligned. However, malalignment in axial rotation was detrimental. Mobile-bearing knee designs with increased articular congruity may result in lower contact stresses, especially the rotating-bearing designs that theoretically minimize rotational malalignment.

Entities:  

Mesh:

Year:  2001        PMID: 11716388     DOI: 10.1097/00003086-200111000-00029

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  39 in total

1.  Surface damage versus tibial polyethylene insert conformity: a retrieval study.

Authors:  Markus A Wimmer; Michel P Laurent; Jeannie D Haman; Joshua J Jacobs; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Rotating platform versus fixed-bearing total knees: an in vitro study of wear.

Authors:  Hani Haider; Kevin Garvin
Journal:  Clin Orthop Relat Res       Date:  2008-08-29       Impact factor: 4.176

3.  Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection.

Authors:  Dae-Hee Lee; Jong-Hoon Park; Dong-Ik Song; Debabrata Padhy; Woong-Kyo Jeong; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-03       Impact factor: 4.342

Review 4.  Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis.

Authors:  Toby O Smith; Farshid Ejtehadi; Rachel Nichols; Leigh Davies; Simon T Donell; Caroline B Hing
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-25       Impact factor: 4.342

5.  Inter-observer precision and physiologic variability of mri landmarks used to determine rotational alignment in conventional and patient-specific TKA.

Authors:  Andrew Park; Denis Nam; Michael V Friedman; Stephen T Duncan; Travis J Hillen; Robert L Barrack
Journal:  J Arthroplasty       Date:  2014-09-06       Impact factor: 4.757

6.  Minimal under-correction gives better outcomes following total knee arthroplasty in severe varus knees-myth or reality?-analysis of one hundred sixty two knees with varus greater than fifteen degrees.

Authors:  Raja Bhaskara Rajasekaran; Dhanasekara Raja Palanisami; Rajkumar Natesan; Shanmuganathan Rajasekaran
Journal:  Int Orthop       Date:  2018-11-20       Impact factor: 3.075

7.  Less femoral lift-off and better femoral alignment in TKA using computer-assisted surgery.

Authors:  Seong Hwan Kim; Han-Jun Lee; Ho-Joong Jung; Jae Sung Lee; Ki Seong Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-10-06       Impact factor: 4.342

8.  No correlation between coronal alignment of total knee arthroplasty and clinical outcomes: a prospective clinical study using 3D-CT.

Authors:  Omer Slevin; Felix Amsler; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-12-22       Impact factor: 4.342

9.  Confirmation of long-term in vivo bearing mobility in eight rotating-platform TKAs.

Authors:  Michael T LaCour; Adrija Sharma; Christopher B Carr; Richard D Komistek; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2014-04-26       Impact factor: 4.176

10.  Improving accuracy of total knee component cementation: description of a simple technique.

Authors:  William B Lutes; Michael A Flierl; Michael R Dayton; Steven J Morgan
Journal:  J Orthop Surg Res       Date:  2009-10-09       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.