Sterilization and wear-related failure in first- and second-generation press-fit condylar total knee arthroplasty.

William L Griffin1, Thomas K Fehring, Donald L Pomeroy, Thomas A Gruen, Jeffrey A Murphy.   

Abstract

UNLABELLED: We compared the incidence of wear-related failures between two large cohorts of patients undergoing total knee arthroplasty implanted with identical modular tibial trays and polyethylene inserts sterilized by different methods. A total of 1183 second-generation press-fit condylar prostheses having inserts packaged and sterilized in an oxygen-free environment were assessed at a minimum 5-year followup (mean, 7.0 years). Wear-related failure was defined as (1) osteolysis greater than 100 mm2 or (2) revision of the implant resulting from osteolysis, polyethylene wear, chronic synovitis, and/or effusion. Wear-related survivorship was calculated using Kaplan-Meier survival analysis. Results were compared with our previously published study of 1287 first-generation press-fit condylar modular knees having inserts sterilized by gamma irradiation in air at 5-year minimum followup (mean, 7.8 years). The wear-related failure rate for the second-generation design was 1.1% and 10-year survivorship was 97.0% compared with 8.3% failure and 87.7% 10-year survival for the first-generation design. For second-generation components, patient age was the only variable correlated with wear-related failure. For first-generation components sterilized in air, several variables were correlated to wear-related failure with shelf age of the polyethylene insert being the most important factor. These data emphasize the dramatic effect improvements in polyethylene manufacturing, specifically sterilization methods, can have on implant survivorship. LEVEL OF EVIDENCE: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18062044

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  14 in total

1.  Long-term survival analysis of posterior cruciate-retaining total knee arthroplasty.

Authors:  Lin Guo; Liu Yang; Jean Louis Briard; Xiao-jun Duan; Fu-you Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-10       Impact factor: 4.342

2.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

3.  Rotating platform versus fixed-bearing total knees: an in vitro study of wear.

Authors:  Hani Haider; Kevin Garvin
Journal:  Clin Orthop Relat Res       Date:  2008-08-29       Impact factor: 4.176

4.  Current modes of failure in TKA: infection, instability, and stiffness predominate.

Authors:  David H Le; Stuart B Goodman; William J Maloney; James I Huddleston
Journal:  Clin Orthop Relat Res       Date:  2014-03-11       Impact factor: 4.176

5.  Polyethylene quality affects revision knee liner exchange survivorship.

Authors:  C Anderson Engh; Nancy L Parks; Gerard A Engh
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

6.  Better survival of total knee replacement in patients older than 70 years: a prospective study with 8 to 12 years follow-up.

Authors:  Ricardo Fernandez-Fernandez; E Carlos Rodriguez-Merchan
Journal:  Arch Bone Jt Surg       Date:  2015-01-15

Review 7.  Towards an understanding of the painful total knee: what is the role of patient biology?

Authors:  Stephen Preston; Massimo Petrera; Christopher Kim; Michael G Zywiel; Rajiv Gandhi
Journal:  Curr Rev Musculoskelet Med       Date:  2016-12

Review 8.  Reoperation After Cervical Disc Arthroplasty Versus Anterior Cervical Discectomy and Fusion: A Meta-analysis.

Authors:  Zhao-Ming Zhong; Shi-Yuan Zhu; Jing-Shen Zhuang; Qian Wu; Jian-Ting Chen
Journal:  Clin Orthop Relat Res       Date:  2016-02-01       Impact factor: 4.176

9.  Effect of Obesity on Component Alignment in Total Knee Arthroplasty.

Authors:  Connor Ojard; Alexander Habashy; Mark Meyer; George Chimento; John L Ochsner
Journal:  Ochsner J       Date:  2018

10.  Component alignment and functional outcome following computer assisted and jig based total knee arthroplasty.

Authors:  Dnyanesh G Lad; Jai Thilak; Mohan Thadi
Journal:  Indian J Orthop       Date:  2013-01       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.