Literature DB >> 23831149

Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers.

D Baykal1, R S Siskey2, H Haider3, V Saikko4, T Ahlroos5, S M Kurtz6.   

Abstract

The introduction of numerous formulations of Ultra-high molecular weight polyethylene (UHMWPE), which is widely used as a bearing material in orthopedic implants, necessitated screening of bearing couples to identify promising iterations for expensive joint simulations. Pin-on-disk (POD) testers capable of multidirectional sliding can correctly rank formulations of UHMWPE with respect to their predictive in vivo wear behavior. However, there are still uncertainties regarding POD test parameters for facilitating clinically relevant wear mechanisms of UHMWPE. Studies on the development of POD testing were briefly summarized. We systematically reviewed wear rate data of UHMWPE generated by POD testers. To determine if POD testing was capable of correctly ranking bearings and if test parameters outlined in ASTM F732 enabled differentiation between wear behavior of various formulations, mean wear rates of non-irradiated, conventional (25-50kGy) and highly crosslinked (≥90kGy) UHMWPE were grouped and compared. The mean wear rates of non-irradiated, conventional and highly crosslinked UHMWPEs were 7.03, 5.39 and 0.67mm(3)/MC. Based on studies that complied with the guidelines of ASTM F732, the mean wear rates of non-irradiated, conventional and highly crosslinked UHMWPEs were 0.32, 0.21 and 0.04mm(3)/km, respectively. In both sets of results, the mean wear rate of highly crosslinked UHMPWE was smaller than both conventional and non-irradiated UHMWPEs (p<0.05). Thus, POD testers can compare highly crosslinked and conventional UHMWPEs despite different test parameters. Narrowing the allowable range for standardized test parameters could improve sensitivity of multi-axial testers in correctly ranking materials.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23831149      PMCID: PMC3864980          DOI: 10.1016/j.jmbbm.2013.05.020

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  35 in total

1.  A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty.

Authors:  C R Bragdon; D O O'Connor; J D Lowenstein; M Jasty; S A Biggs; W H Harris
Journal:  J Arthroplasty       Date:  2001-08       Impact factor: 4.757

2.  The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements.

Authors:  S Sathasivam; P S Walker; P A Campbell; K Rayner
Journal:  J Biomed Mater Res       Date:  2001-05-01

3.  A surface crosslinked UHMWPE stabilized by vitamin E with low wear and high fatigue strength.

Authors:  Ebru Oral; Bassem W Ghali; Shannon L Rowell; Brad R Micheli; Andrew J Lozynsky; Orhun K Muratoglu
Journal:  Biomaterials       Date:  2010-06-25       Impact factor: 12.479

4.  A study of the wear resistance of three types of clinically applied UHMWPE for total replacement hip prostheses.

Authors:  P S Barbour; M H Stone; J Fisher
Journal:  Biomaterials       Date:  1999-11       Impact factor: 12.479

5.  Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: effect of head diameter.

Authors:  Lu Kang; Alison L Galvin; John Fisher; Zhongmin Jin
Journal:  J Biomech       Date:  2009-03-03       Impact factor: 2.712

6.  A holistic numerical model to predict strain hardening and damage of UHMWPE under multiple total knee replacement kinematics and experimental validation.

Authors:  Ryan Willing; Il Yong Kim
Journal:  J Biomech       Date:  2009-08-03       Impact factor: 2.712

7.  RandomPOD--a new method and device for advanced wear simulation of orthopaedic biomaterials.

Authors:  Vesa Saikko; Jari Kostamo
Journal:  J Biomech       Date:  2011-02-01       Impact factor: 2.712

8.  Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses.

Authors:  A Wang; C Stark; J H Dumbleton
Journal:  Proc Inst Mech Eng H       Date:  1996       Impact factor: 1.617

9.  Wear testing of materials and surfaces for total knee replacement.

Authors:  P S Walker; G W Blunn; P A Lilley
Journal:  J Biomed Mater Res       Date:  1996

10.  Wear studies on prosthetic materials using the pin-on-disc machine.

Authors:  K W Wright; H S Dobbs; J T Scales
Journal:  Biomaterials       Date:  1982-01       Impact factor: 12.479

View more
  7 in total

1.  The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.

Authors:  Doruk Baykal; Ryan S Siskey; Richard J Underwood; Adam Briscoe; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

2.  Multidirectional wear and impact-to-wear tests of phospholipid-polymer-grafted and vitamin E-blended crosslinked polyethylene: a pilot study.

Authors:  Masayuki Kyomoto; Toru Moro; Yoshio Takatori; Sakae Tanaka; Kazuhiko Ishihara
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

3.  Tribo-corrosive behavior of additive manufactured parts for orthopaedic applications.

Authors:  Abrar Malik; Saquib Rouf; Mir Irfan Ul Haq; Ankush Raina; Ana Pilar Valerga Puerta; Binnur Sagbas; Alessandro Ruggiero
Journal:  J Orthop       Date:  2022-08-10

4.  Wear testing of moderate activities of daily living using in vivo measured knee joint loading.

Authors:  Jörn Reinders; Robert Sonntag; Leo Vot; Christian Gibney; Moritz Nowack; Jan Philippe Kretzer
Journal:  PLoS One       Date:  2015-03-26       Impact factor: 3.240

5.  Can pin-on-disk testing be used to assess the wear performance of retrieved UHMWPE components for total joint arthroplasty?

Authors:  Steven M Kurtz; Daniel W MacDonald; Sevi Kocagöz; Mariya Tohfafarosh; Doruk Baykal
Journal:  Biomed Res Int       Date:  2014-09-11       Impact factor: 3.411

6.  A Fully Functional Drug-Eluting Joint Implant.

Authors:  V J Suhardi; D A Bichara; Sjj Kwok; A A Freiberg; H Rubash; H Malchau; S H Yun; O K Muratoglu; E Oral
Journal:  Nat Biomed Eng       Date:  2017-06-13       Impact factor: 25.671

7.  Effects of Surface Modification and Bulk Geometry on the Biotribological Behavior of Cross-Linked Polyethylene: Wear Testing and Finite Element Analysis.

Authors:  Kenichi Watanabe; Masayuki Kyomoto; Kenichi Saiga; Shuji Taketomi; Hiroshi Inui; Yuho Kadono; Yoshio Takatori; Sakae Tanaka; Kazuhiko Ishihara; Toru Moro
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

  7 in total