Literature DB >> 18581383

Measurement of T1 and T2 in the cervical spinal cord at 3 tesla.

Seth A Smith1, Richard A E Edden, Jonathan A D Farrell, Peter B Barker, Peter C M Van Zijl.   

Abstract

T(1) and T(2) were measured for white matter (WM) and gray matter (GM) in the human cervical spinal cord at 3T. T(1) values were calculated using an inversion-recovery (IR) and B(1)-corrected double flip angle gradient echo (GRE) and show significant differences (p = 0.002) between WM (IR = 876 +/- 27 ms, GRE = 838 +/- 54 ms) and GM (IR = 973 +/- 33 ms, GRE = 994 +/- 54 ms). IR showed significant difference between lateral and dorsal column WM (863 +/- 23 ms and 899 +/- 18 ms, respectively, p = 0.01) but GRE did not (p = 0.40). There was no significant difference (p = 0.31) in T(2) between WM (73 +/- 6 ms) and GM (76 +/- 3 ms) or between lateral and dorsal columns (lateral: 73 +/- 6 ms, dorsal: 72 +/- 7 ms, p = 0.59). WM relaxation times were similar to brain structures with very dense fiber packing (e.g., corpus callosum), while GM values resembled deep GM in brain. Optimized sequence parameters for maximal contrast between WM and GM, and between WM and cerebrospinal fluid (CSF) were derived. Since the spinal cord has rostral-caudal symmetry, we expect these findings to be applicable to the whole cord. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18581383      PMCID: PMC2887301          DOI: 10.1002/mrm.21596

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Role of MRI in acute transverse myelitis.

Authors:  U K Misra; J Kalita
Journal:  Neurol India       Date:  1999-12       Impact factor: 2.117

2.  NMR relaxation times in the human brain at 3.0 tesla.

Authors:  J P Wansapura; S K Holland; R S Dunn; W S Ball
Journal:  J Magn Reson Imaging       Date:  1999-04       Impact factor: 4.813

3.  Diffusion tensor MRI of the spinal cord.

Authors:  M Ries; R A Jones; V Dousset; C T Moonen
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

4.  In vivo magnetic resonance imaging of the human cervical spinal cord at 3 Tesla.

Authors:  Jeffrey R Korzan; Monica Gorassini; Derek Emery; Zaki A Taher; Christian Beaulieu
Journal:  J Magn Reson Imaging       Date:  2002-07       Impact factor: 4.813

5.  Magnetization transfer weighted imaging in the upper cervical spinal cord using cerebrospinal fluid as intersubject normalization reference (MTCSF imaging).

Authors:  Seth A Smith; Xavier Golay; Ali Fatemi; Craig K Jones; Gerald V Raymond; Hugo W Moser; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

6.  T1, T2 relaxation and magnetization transfer in tissue at 3T.

Authors:  Greg J Stanisz; Ewa E Odrobina; Joseph Pun; Michael Escaravage; Simon J Graham; Michael J Bronskill; R Mark Henkelman
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

7.  Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

8.  Rapid high-resolution T(1) mapping by variable flip angles: accurate and precise measurements in the presence of radiofrequency field inhomogeneity.

Authors:  Hai-Ling Margaret Cheng; Graham A Wright
Journal:  Magn Reson Med       Date:  2006-03       Impact factor: 4.668

9.  Pulsed magnetization transfer imaging with body coil transmission at 3 Tesla: feasibility and application.

Authors:  Seth A Smith; Jonathan A D Farrell; Craig K Jones; Daniel S Reich; Peter A Calabresi; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

10.  A simple correction for B1 field errors in magnetization transfer ratio measurements.

Authors:  Rebecca S Samson; Claudia A M Wheeler-Kingshott; Mark R Symms; Daniel J Tozer; Paul S Tofts
Journal:  Magn Reson Imaging       Date:  2005-12-27       Impact factor: 2.546

View more
  28 in total

1.  Assessment of unilateral ureter obstruction with multi-parametric MRI.

Authors:  Feng Wang; Keiko Takahashi; Hua Li; Zhongliang Zu; Ke Li; Junzhong Xu; Raymond C Harris; Takamune Takahashi; John C Gore
Journal:  Magn Reson Med       Date:  2017-07-24       Impact factor: 4.668

2.  Assessment of renal fibrosis in murine diabetic nephropathy using quantitative magnetization transfer MRI.

Authors:  Feng Wang; Daisuke Katagiri; Ke Li; Keiko Takahashi; Suwan Wang; Shinya Nagasaka; Hua Li; C Chad Quarles; Ming-Zhi Zhang; Akira Shimizu; John C Gore; Raymond C Harris; Takamune Takahashi
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

3.  Measurement of T2* in the human spinal cord at 3T.

Authors:  Robert L Barry; Seth A Smith
Journal:  Magn Reson Med       Date:  2019-03-28       Impact factor: 4.668

4.  Groupwise multi-atlas segmentation of the spinal cord's internal structure.

Authors:  Andrew J Asman; Frederick W Bryan; Seth A Smith; Daniel S Reich; Bennett A Landman
Journal:  Med Image Anal       Date:  2014-02-05       Impact factor: 8.545

5.  g-Ratio weighted imaging of the human spinal cord in vivo.

Authors:  T Duval; S Le Vy; N Stikov; J Campbell; A Mezer; T Witzel; B Keil; V Smith; L L Wald; E Klawiter; J Cohen-Adad
Journal:  Neuroimage       Date:  2016-09-22       Impact factor: 6.556

6.  Towards microstructure fingerprinting: Estimation of tissue properties from a dictionary of Monte Carlo diffusion MRI simulations.

Authors:  Gaëtan Rensonnet; Benoît Scherrer; Gabriel Girard; Aleksandar Jankovski; Simon K Warfield; Benoît Macq; Jean-Philippe Thiran; Maxime Taquet
Journal:  Neuroimage       Date:  2018-09-30       Impact factor: 6.556

7.  Longitudinal assessment of mouse renal injury using high-resolution anatomic and magnetization transfer MR imaging.

Authors:  Feng Wang; Rosie Jiang; Keiko Takahashi; John Gore; Raymond C Harris; Takamune Takahashi; C Chad Quarles
Journal:  Magn Reson Imaging       Date:  2014-08-02       Impact factor: 2.546

8.  3 T MRI relaxometry detects T2 prolongation in the cerebral normal-appearing white matter in multiple sclerosis.

Authors:  Mohit Neema; Daniel Goldberg-Zimring; Zachary D Guss; Brian C Healy; Charles R G Guttmann; Maria K Houtchens; Howard L Weiner; Mark A Horsfield; David B Hackney; David C Alsop; Rohit Bakshi
Journal:  Neuroimage       Date:  2009-03-10       Impact factor: 6.556

9.  Chemical exchange saturation transfer of the cervical spinal cord at 7 T.

Authors:  Adrienne N Dula; Siddharama Pawate; Lindsey M Dethrage; Benjamin N Conrad; Blake E Dewey; Robert L Barry; Seth A Smith
Journal:  NMR Biomed       Date:  2016-07-26       Impact factor: 4.044

Review 10.  The current state-of-the-art of spinal cord imaging: methods.

Authors:  P W Stroman; C Wheeler-Kingshott; M Bacon; J M Schwab; R Bosma; J Brooks; D Cadotte; T Carlstedt; O Ciccarelli; J Cohen-Adad; A Curt; N Evangelou; M G Fehlings; M Filippi; B J Kelley; S Kollias; A Mackay; C A Porro; S Smith; S M Strittmatter; P Summers; I Tracey
Journal:  Neuroimage       Date:  2013-05-14       Impact factor: 6.556

View more