Literature DB >> 11108625

Diffusion tensor MRI of the spinal cord.

M Ries1, R A Jones, V Dousset, C T Moonen.   

Abstract

Apparent diffusion tensor (ADT) measurements on the spinal cord using a pulsed-field-gradient (PFG) multi-shot echo-planar imaging (EPI) sequence are presented. In a study of 10 healthy volunteers, the obtained rotationally invariant anisotropy information is compared to the results obtained by the rotationally dependent methods. The water diffusivity in the direction parallel to the fibers was found to be almost 2.5 times higher than the average diffusivity in directions perpendicular to the fibers and showed cylindrically symmetric anisotropy characteristics. The influence of partial volume effects and the point spread function on the measured results was evaluated, and it was the concluded that a resolution of 1 mm in the read and phase directions is required to obtain unbiased values. Possible clinical implications were demonstrated by investigating the diffusion characteristics of 10 patients suffering from narrowing of the cervical canal. The changes in the diffusion characteristics were found to be large enough to allow a robust detection of diffusion changes in the spine, even in cases in which conventional T(2) and T(1) weighted images were unable to detect any lesion.

Entities:  

Mesh:

Year:  2000        PMID: 11108625     DOI: 10.1002/1522-2594(200012)44:6<884::aid-mrm9>3.0.co;2-q

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  41 in total

1.  Diffusivity of intraorbital lymphoma vs. inflammation: comparison of single shot turbo spin echo and multishot echo planar imaging techniques.

Authors:  Akio Hiwatashi; Osamu Togao; Koji Yamashita; Kazufumi Kikuchi; Ryotaro Kamei; Hiroshi Yoshikawa; Atsushi Takemura; Hiroshi Honda
Journal:  Eur Radiol       Date:  2017-08-04       Impact factor: 5.315

2.  Sensitivity-encoded diffusion tensor MR imaging of the cervical cord.

Authors:  Mara Cercignani; Mark A Horsfield; Federica Agosta; Massimo Filippi
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

3.  Diffusion tensor imaging in the cervical spinal cord.

Authors:  Ting Song; Wen-Jun Chen; Bo Yang; Hong-Pu Zhao; Jian-Wei Huang; Ming-Jin Cai; Tian-Fa Dong; Tang-Sheng Li
Journal:  Eur Spine J       Date:  2010-10-13       Impact factor: 3.134

4.  Diffusion tractography of the cervical spinal cord by using parallel imaging.

Authors:  Kazuhiro Tsuchiya; Akira Fujikawa; Yuriko Suzuki
Journal:  AJNR Am J Neuroradiol       Date:  2005-02       Impact factor: 3.825

5.  A preliminary study of the effects of trigger timing on diffusion tensor imaging of the human spinal cord.

Authors:  P Summers; P Staempfli; T Jaermann; S Kwiecinski; S Kollias
Journal:  AJNR Am J Neuroradiol       Date:  2006-10       Impact factor: 3.825

Review 6.  Examination of spinal cord tissue architecture with magnetic resonance diffusion tensor imaging.

Authors:  Stephan E Maier
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

7.  Diffusion tensor imaging of ex vivo cervical spinal cord specimens: the immediate and long-term effects of fixation on diffusivity.

Authors:  T H Kim; L Zollinger; X F Shi; J Rose; E-K Jeong
Journal:  Anat Rec (Hoboken)       Date:  2009-02       Impact factor: 2.064

8.  Polyethylene glycol-induced motor recovery after total spinal transection in rats.

Authors:  Shuai Ren; Ze-Han Liu; Qiong Wu; Kuang Fu; Jun Wu; Li-Ting Hou; Ming Li; Xin Zhao; Qing Miao; Yun-Long Zhao; Sheng-Yu Wang; Yan Xue; Zhen Xue; Ya-Shan Guo; Sergio Canavero; Xiao-Ping Ren
Journal:  CNS Neurosci Ther       Date:  2017-06-14       Impact factor: 5.243

9.  Diffusion-weighted MRI in acute spinal cord ischaemia.

Authors:  T J Loher; C L Bassetti; K O Lövblad; F P Stepper; M Sturzenegger; C Kiefer; K Nedeltchev; M Arnold; L Remonda; G Schroth
Journal:  Neuroradiology       Date:  2003-06-27       Impact factor: 2.804

10.  Quantification of diffusivities of the human cervical spinal cord using a 2D single-shot interleaved multisection inner volume diffusion-weighted echo-planar imaging technique.

Authors:  T H Kim; L Zollinger; X F Shi; S E Kim; J Rose; A A Patel; E K Jeong
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-17       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.