Literature DB >> 30924198

Measurement of T2* in the human spinal cord at 3T.

Robert L Barry1,2,3, Seth A Smith4,5,6.   

Abstract

PURPOSE: To measure the transverse relaxation time T2* in healthy human cervical spinal cord gray matter (GM) and white matter (WM) at 3T.
METHODS: Thirty healthy volunteers were recruited. Axial images were acquired using an averaged multi-echo gradient-echo (mFFE) T2*-weighted sequence with 5 echoes. We used the signal equation for an mFFE sequence with constant dephasing gradients after each echo to jointly estimate the spin density and T2* for each voxel.
RESULTS: No global difference in T2* was observed between all GM (41.3 ± 5.6 ms) and all WM (39.8 ± 5.4 ms). No significant differences were observed between left (43.2 ± 6.8 ms) and right (43.4 ± 5.5 ms) ventral GM, left (38.3 ± 6.1 ms) and right (38.6 ± 6.5 ms) dorsal GM, and left (39.4 ± 5.8 ms) and right (40.3 ± 5.8 ms) lateral WM. However, significant regional differences were observed between ventral (43.4 ± 5.7 ms) and dorsal (38.4 ± 6.0 ms) GM (p < 0.05), as well as between ventral (42.9 ± 6.5 ms) and dorsal (37.9 ± 6.2 ms) WM (p < 0.05). In analyses across slices, inferior T2* was longer than superior T2* in GM (44.7 ms vs. 40.1 ms; p < 0.01) and in WM (41.8 ms vs. 35.9 ms; p < 0.01).
CONCLUSIONS: Significant differences in T2* are observed between ventral and dorsal GM, ventral and dorsal WM, and superior and inferior GM and WM. There is no evidence for bilateral asymmetry in T2* in the healthy cord. These values of T2* in the spinal cord are notably lower than most reported values of T2* in the cortex.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  3 Tesla; T2* mapping; healthy controls; multi-echo gradient-echo imaging; relaxometry; spinal cord

Mesh:

Year:  2019        PMID: 30924198      PMCID: PMC6510624          DOI: 10.1002/mrm.27755

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging.

Authors:  G Krüger; A Kastrup; G H Glover
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

Review 2.  Fast Field Echo imaging: an overview and contrast calculations.

Authors:  P van der Meulen; J P Groen; A M Tinus; G Bruntink
Journal:  Magn Reson Imaging       Date:  1988 Jul-Aug       Impact factor: 2.546

3.  Clinically Feasible Microstructural MRI to Quantify Cervical Spinal Cord Tissue Injury Using DTI, MT, and T2*-Weighted Imaging: Assessment of Normative Data and Reliability.

Authors:  A R Martin; B De Leener; J Cohen-Adad; D W Cadotte; S Kalsi-Ryan; S F Lange; L Tetreault; A Nouri; A Crawley; D J Mikulis; H Ginsberg; M G Fehlings
Journal:  AJNR Am J Neuroradiol       Date:  2017-04-20       Impact factor: 3.825

4.  A Novel MRI Biomarker of Spinal Cord White Matter Injury: T2*-Weighted White Matter to Gray Matter Signal Intensity Ratio.

Authors:  A R Martin; B De Leener; J Cohen-Adad; D W Cadotte; S Kalsi-Ryan; S F Lange; L Tetreault; A Nouri; A Crawley; D J Mikulis; H Ginsberg; M G Fehlings
Journal:  AJNR Am J Neuroradiol       Date:  2017-04-20       Impact factor: 3.825

5.  Spatial distribution of multiple sclerosis lesions in the cervical spinal cord.

Authors:  Dominique Eden; Charley Gros; Atef Badji; Sara M Dupont; Benjamin De Leener; Josefina Maranzano; Ren Zhuoquiong; Yaou Liu; Tobias Granberg; Russell Ouellette; Leszek Stawiarz; Jan Hillert; Jason Talbott; Elise Bannier; Anne Kerbrat; Gilles Edan; Pierre Labauge; Virginie Callot; Jean Pelletier; Bertrand Audoin; Henitsoa Rasoanandrianina; Jean-Christophe Brisset; Paola Valsasina; Maria A Rocca; Massimo Filippi; Rohit Bakshi; Shahamat Tauhid; Ferran Prados; Marios Yiannakas; Hugh Kearney; Olga Ciccarelli; Seth A Smith; Constantina Andrada Treaba; Caterina Mainero; Jennifer Lefeuvre; Daniel S Reich; Govind Nair; Timothy M Shepherd; Erik Charlson; Yasuhiko Tachibana; Masaaki Hori; Kouhei Kamiya; Lydia Chougar; Sridar Narayanan; Julien Cohen-Adad
Journal:  Brain       Date:  2019-03-01       Impact factor: 13.501

6.  High-resolution multi-parametric quantitative magnetic resonance imaging of the human cervical spinal cord at 7T.

Authors:  Aurélien Massire; Manuel Taso; Pierre Besson; Maxime Guye; Jean-Philippe Ranjeva; Virginie Callot
Journal:  Neuroimage       Date:  2016-08-26       Impact factor: 6.556

7.  Topologically preserving straightening of spinal cord MRI.

Authors:  Benjamin De Leener; Gabriel Mangeat; Sara Dupont; Allan R Martin; Virginie Callot; Nikola Stikov; Michael G Fehlings; Julien Cohen-Adad
Journal:  J Magn Reson Imaging       Date:  2017-01-27       Impact factor: 4.813

8.  Dynamic per slice shimming for simultaneous brain and spinal cord fMRI.

Authors:  Haisam Islam; Christine S W Law; Kenneth A Weber; Sean C Mackey; Gary H Glover
Journal:  Magn Reson Med       Date:  2018-10-04       Impact factor: 4.668

9.  Axial 3D gradient-echo imaging for improved multiple sclerosis lesion detection in the cervical spinal cord at 3T.

Authors:  Arzu Ozturk; Nafi Aygun; Seth A Smith; Brian Caffo; Peter A Calabresi; Daniel S Reich
Journal:  Neuroradiology       Date:  2012-12-04       Impact factor: 2.804

10.  Tumor detection by nuclear magnetic resonance.

Authors:  R Damadian
Journal:  Science       Date:  1971-03-19       Impact factor: 47.728

View more
  2 in total

1.  Multi-shot acquisitions for stimulus-evoked spinal cord BOLD fMRI.

Authors:  Robert L Barry; Benjamin N Conrad; Satoshi Maki; Jennifer M Watchmaker; Lydia J McKeithan; Bailey A Box; Quinn R Weinberg; Seth A Smith; John C Gore
Journal:  Magn Reson Med       Date:  2020-11-10       Impact factor: 4.668

2.  Optimized multi-echo gradient-echo magnetic resonance imaging for gray and white matter segmentation in the lumbosacral cord at 3 T.

Authors:  Silvan Büeler; Marios C Yiannakas; Zdravko Damjanovski; Patrick Freund; Martina D Liechti; Gergely David
Journal:  Sci Rep       Date:  2022-10-03       Impact factor: 4.996

  2 in total