Literature DB >> 18561683

An investigation of the accuracy of an IMRT dose distribution using two- and three-dimensional dosimetry techniques.

Mark Oldham1, Harshad Sakhalkar, Pengyi Guo, John Adamovics.   

Abstract

Complex dose delivery techniques like intensity-modulated radiation therapy (IMRT) require dose measurement in three dimensions for comprehensive validation. Previously, we demonstrated the feasibility of the "PRESAGE/optical-computed tomography (CT)" system for the three-dimensional verification of simple open beam dose distributions where the planning system was known to be accurate. The present work extends this effort and presents the first application of the PRESAGE/optical-CT system for the verification of a complex IMRT distribution. A highly modulated 11 field IMRT plan was delivered to a cylindrical PRESAGE dosimeter (16 cm in diameter and 11 cm in height), and the dose distribution was readout using a commercial scanning-laser optical-CT scanner. Comparisons were made with independent GAFCHROMIC EBT film measurements, and the calculated dose distribution from a commissioned treatment planning system (ECLIPSE). Isodose plots, dose profiles, gamma maps, and dose-volume histograms were used to evaluate the agreement. The isodose plots and dose profiles from the PRESAGE/optical-CT system were in excellent agreement with both the EBT measurements and the ECLIPSE calculation at all points except within 3 mm of the outer edge of the dosimeter where an edge artifact occurred. Excluding this 3 mm rim, gamma map comparisons show that all three distributions mutually agreed to within a 3% (dose difference) and 3 mm (distance-to-agreement) criteria. A 96% gamma pass ratio was obtained between the PRESAGE and ECLIPSE distributions over the entire volume excluding this rim. In conclusion, for the complex IMRT plan studied, and in the absence of inhomogeneities, the ECLIPSE dose calculation was found to agree with both independent measurements, to within 3%, 3 mm gamma criteria.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18561683      PMCID: PMC2562315          DOI: 10.1118/1.2899995

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Optical-CT gel-dosimetry. II: Optical artifacts and geometrical distortion.

Authors:  Mark Oldham; Leonard Kim
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

2.  Validation and application of polymer gel dosimetry for the dose verification of an intensity-modulated arc therapy (IMAT) treatment.

Authors:  K Vergote; Y De Deene; W Duthoy; W De Gersem; W De Neve; E Achten; C De Wagter
Journal:  Phys Med Biol       Date:  2004-01-21       Impact factor: 3.609

3.  Characterization and use of EBT radiochromic film for IMRT dose verification.

Authors:  Omar A Zeidan; Stacy Ann L Stephenson; Sanford L Meeks; Thomas H Wagner; Twyla R Willoughby; Patrick A Kupelian; Katja M Langen
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

4.  Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry.

Authors:  Nikola Krstajić; Simon J Doran
Journal:  Phys Med Biol       Date:  2006-04-03       Impact factor: 3.609

5.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

6.  3D dosimetry by optical-CT scanning.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2006

7.  Determining optimal gel sensitivity in optical CT scanning of gel dosimeters.

Authors:  Y Xua; Cheng-Shie Wuu; Marek J Maryanski
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

8.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel.

Authors:  M J Maryañski; Y Z Zastavker; J C Gore
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

9.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner.

Authors:  J C Gore; M Ranade; M J Maryañski; R J Schulz
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

10.  Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter.

Authors:  R G Kelly; K J Jordan; J J Battista
Journal:  Med Phys       Date:  1998-09       Impact factor: 4.071

View more
  13 in total

1.  Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques.

Authors:  Joseph Newton; Mark Oldham; Andrew Thomas; Yifan Li; John Adamovics; David G Kirsch; Shiva Das
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  A 'quad-phantom' film dosimeter for use as a multi-planar verification tool for PRESAGE/optical-CT.

Authors:  L Stunja; A Thomas; J Adamovics; J Deasy; M Oldham
Journal:  J Phys Conf Ser       Date:  2010

3.  A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.

Authors:  H S Sakhalkar; J Adamovics; G Ibbott; M Oldham
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

4.  Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using presage/optical-CT.

Authors:  Harshad Sakhalkar; David Sterling; John Adamovics; Geoffrey Ibbott; Mark Oldham
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

5.  Commissioning and benchmarking a 3D dosimetry system for clinical use.

Authors:  Andrew Thomas; Joseph Newton; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

6.  Investigation into the feasibility of using PRESAGE/optical-CT dosimetry for the verification of gating treatments.

Authors:  Samuel L Brady; William E Brown; Corey G Clift; Sua Yoo; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-03-26       Impact factor: 3.609

7.  On the feasibility of comprehensive high-resolution 3D remote dosimetry.

Authors:  Titania Juang; Ryan Grant; John Adamovics; Geoffrey Ibbott; Mark Oldham
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

8.  Feasibility of using PRESAGE® for relative 3D dosimetry of small proton fields.

Authors:  Li Zhao; Joseph Newton; Mark Oldham; Indra J Das; Chee-Wai Cheng; John Adamovics
Journal:  Phys Med Biol       Date:  2012-10-26       Impact factor: 3.609

9.  Validation of Dolphin dosimetry in three dimensional patient-specific quality assurance programme.

Authors:  Niyas Puzhakkal; Abdullah Kallikuzhiyil Kochunny; Dinesh Makuny; Arun Krishnan M P; Ranjith C Poyil; Vysakh Raveendran
Journal:  Rep Pract Oncol Radiother       Date:  2019-08-12

10.  Is It Possible to Publish a Calibration Function for Radiochromic Film?

Authors:  Maria F Chan; David Lewis; Xiang Yu
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2014-01-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.