Feasibility of using PRESAGE® for relative 3D dosimetry of small proton fields.

Li Zhao1, Joseph Newton, Mark Oldham, Indra J Das, Chee-Wai Cheng, John Adamovics.   

Abstract

Small field dosimetry is challenging due to the finite size of the conventional detectors that underestimate the dose distribution. With the fast development of the dynamic proton beam delivery system, it is essential to find a dosimeter which can be used for 3D dosimetry of small proton fields. We investigated the feasibility of using a proton formula PRESAGE® for 3D dosimetry of small fields in a uniform scanning proton beam delivery system with dose layer stacking technology. The relationship between optical density and the absorbed dose was found to be linear through small volume cuvette studies for both photon and proton irradiation. Two circular fields and three patient-specific fields were used for proton treatment planning calculation and beam delivery. The measured results were compared with the calculated results in the form of lateral dose profiles, depth dose, isodose plots and gamma index analysis. For the circular field study, lateral dose profile comparison showed that the relative PRESAGE® profile falls within ± 5% from the calculated profile for most of the spatial range. For unmodulated depth dose comparison, the agreement between the measured and calculated results was within 3% in the beam entrance region before the Bragg peak. However, at the Bragg peak, there was about 20% underestimation of the absorbed dose from PRESAGE®. For patient-specific field 3D dosimetry, most of the data points within the target volume passed gamma analysis for 3% relative dose difference and 3 mm distance to agreement criteria. Our results suggest that this proton formula PRESAGE® dosimeter has the potential for 3D dosimetry of small fields in proton therapy, but further investigation is needed to improve the dose under-response of the PRESAGE® in the Bragg peak region.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23103526      PMCID: PMC3844616          DOI: 10.1088/0031-9155/57/22/N431

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

1.  Gafchromic EBT film dosimetry in proton beams.

Authors:  Li Zhao; Indra J Das
Journal:  Phys Med Biol       Date:  2010-04-29       Impact factor: 3.609

2.  Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy.

Authors:  O A Zeidan; S I Sriprisan; O Lopatiuk-Tirpak; P A Kupelian; S L Meeks; W C Hsi; Z Li; J R Palta; M J Maryanski
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  Preliminary commissioning investigations with the DMOS-RPC optical-CT Scanner.

Authors:  J Newton; A Thomas; G Ibbott; M Oldham
Journal:  J Phys Conf Ser       Date:  2010

4.  Determination of the depth dose distribution of proton beam using PRESAGE™ dosimeter.

Authors:  L Zhao; I J Das; Q Zhao; A Thomas; J Adamovics; M Oldman
Journal:  J Phys Conf Ser       Date:  2010

5.  Determination of output factors for small proton therapy fields.

Authors:  Jonas D Fontenot; Wayne D Newhauser; Charles Bloch; R Allen White; Uwe Titt; George Starkschall
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

6.  Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method.

Authors:  Uwe Titt; Yuanshui Zheng; Oleg N Vassiliev; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2007-12-28       Impact factor: 3.609

7.  Investigation of the feasibility of relative 3D dosimetry in the Radiologic Physics Center Head and Neck IMRT phantom using presage/optical-CT.

Authors:  Harshad Sakhalkar; David Sterling; John Adamovics; Geoffrey Ibbott; Mark Oldham
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

8.  Investigation of radiological properties and water equivalency of PRESAGE dosimeters.

Authors:  Tina Gorjiara; Robin Hill; Zdenka Kuncic; John Adamovics; Stephen Bosi; Jung-Ha Kim; Clive Baldock
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

9.  Planning proton therapy of the eye.

Authors:  M Goitein; T Miller
Journal:  Med Phys       Date:  1983 May-Jun       Impact factor: 4.071

10.  Proton irradiation of small choroidal malignant melanomas.

Authors:  E S Gragoudas; M Goitein; A M Koehler; L Verhey; J Tepper; H D Suit; R Brockhurst; I J Constable
Journal:  Am J Ophthalmol       Date:  1977-05       Impact factor: 5.258

View more
  8 in total

1.  An investigation of a PRESAGE® in vivo dosimeter for brachytherapy.

Authors:  A K Vidovic; T Juang; S Meltsner; J Adamovics; J Chino; B Steffey; O Craciunescu; M Oldham
Journal:  Phys Med Biol       Date:  2014-06-24       Impact factor: 3.609

2.  3D reconstruction of scintillation light emission from proton pencil beams using limited viewing angles-a simulation study.

Authors:  CheukKai Hui; Daniel Robertson; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-07-23       Impact factor: 3.609

Review 3.  Towards effective and efficient patient-specific quality assurance for spot scanning proton therapy.

Authors:  X Ronald Zhu; Yupeng Li; Dennis Mackin; Heng Li; Falk Poenisch; Andrew K Lee; Anita Mahajan; Steven J Frank; Michael T Gillin; Narayan Sahoo; Xiaodong Zhang
Journal:  Cancers (Basel)       Date:  2015-04-10       Impact factor: 6.639

4.  Issues involved in the quantitative 3D imaging of proton doses using optical CT and chemical dosimeters.

Authors:  Simon Doran; Tina Gorjiara; Andrzej Kacperek; John Adamovics; Zdenka Kuncic; Clive Baldock
Journal:  Phys Med Biol       Date:  2015-01-02       Impact factor: 3.609

Review 5.  A Review of PRESAGE Radiochromic Polymer and the Compositions for Application in Radiotherapy Dosimetry.

Authors:  Muhammad Zamir Mohyedin; Hafiz Mohd Zin; Mohd Zulfadli Adenan; Ahmad Taufek Abdul Rahman
Journal:  Polymers (Basel)       Date:  2022-07-16       Impact factor: 4.967

Review 6.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

7.  Comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film with a commercial radiation treatment planning system for breast IMRT: a feasibility study.

Authors:  Khalid Iqbal; Kent A Gifford; Geoffrey Ibbott; Ryan L Grant; Saeed Buzdar
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

8.  Improvement in sensitivity of radiochromic 3D dosimeter based on rigid polyurethane resin by incorporating tartrazine.

Authors:  Jin Dong Cho; Jaeman Son; Chang Heon Choi; Jin Sung Kim; Hong-Gyun Wu; Jong Min Park; Jung-In Kim
Journal:  PLoS One       Date:  2020-03-16       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.