Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel.

M J Maryañski1, Y Z Zastavker, J C Gore.   

Abstract

A newly developed method of radiation dosimetry makes use of the optical properties of polymer gels. The dose-response mechanism relies on the production of light-scattering polymer micro-particles in the gel at each site of radiation absorption. The scattering produces an attenuation of transmitted light intensity that is directly related to the dose and independent of dose rate. For the BANG polymer gel (bis, acrylamide, nitrogen, and gelatin) the shape of the dose-response curve depends on the fraction of the cross-linking monomer in the initial mixture and on the wavelength of light. At 500 nm the attenuation coefficient (mu) increases by approximately 0.7 mm-1 when the dose increases from 0 to 5 Gy. The refractive index of an irradiated gel shows no significant dispersion in the visible region and depends only slightly on the dose. Turbidity difference spectra are compared with theoretical spectra of efficiency factors for total scattering, derived using Mie-Debye theory, and the average sizes of the cross-linked particles produced by radiation, as a function of dose, are established. The particle sizes increase with dose and reach approximately the wavelength of red light. The dependence of the particle sizes on cross-linker fraction parallels a similar dependence of the water proton NMR transverse relaxation rate dose response.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8971964     DOI: 10.1088/0031-9155/41/12/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  29 in total

1.  Optical-CT gel-dosimetry I: basic investigations.

Authors:  Mark Oldham; Jeffrey H Siewerdsen; Sai Kumar; John Wong; David A Jaffray
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

2.  Optical-CT gel-dosimetry. II: Optical artifacts and geometrical distortion.

Authors:  Mark Oldham; Leonard Kim
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

3.  Theoretical and empirical investigations of KCl : Eu2+ for nearly water-equivalent radiotherapy dosimetry.

Authors:  Yuanshui Zheng; Zhaohui Han; Joseph P Driewer; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

4.  Characterization of a new radiochromic three-dimensional dosimeter.

Authors:  P Y Guo; J A Adamovics; M Oldham
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

5.  Optical-CT scanning of polymer gels.

Authors:  M Oldham
Journal:  J Phys Conf Ser       Date:  2004

6.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

7.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

8.  A dual-purpose CCD based micro-optical-CT scanning system.

Authors:  M Oldham; H Sakhalkar; P Guo
Journal:  J Phys Conf Ser       Date:  2006-12-01

9.  3D dosimetry by optical-CT scanning.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2006

10.  An investigation of the accuracy of an IMRT dose distribution using two- and three-dimensional dosimetry techniques.

Authors:  Mark Oldham; Harshad Sakhalkar; Pengyi Guo; John Adamovics
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.