Literature DB >> 12945992

Determining optimal gel sensitivity in optical CT scanning of gel dosimeters.

Y Xua1, Cheng-Shie Wuu, Marek J Maryanski.   

Abstract

A method for determining the gel sensitivity that is necessary for obtaining optimal image contrast in optical CT scanning of gel dosimeters is presented. The effective dynamic range of the OCTOPUS-ONE research scanner (MGS Research, Inc., Madison, CT) is analyzed. Optical density increments for selected straight-line paths across a gel cylinder to be scanned are calculated based on the optical properties of the polymer gel and the dose distribution from a commercial treatment planning system (Cadplan, Varian Corporation, Palo Alto, CA). Maximum optical density increment across the entire gel is obtained by searching the gel cylinder over a set of transverse planes at different rotational angles. The application of this quantity as a criterion for optimizing the quality of the optical CT scanning is demonstrated through dose verification of two representative treatment plans. When the MU dependence of the dose distribution for a treatment plan is linear, as is the case for static field irradiation, it is possible to scale the treatment plan such that the intensity variation of the signals received by the photodetector spans its entire dynamic range. For treatment plans that are possibly nonlinear, IMRT plans, for example, modification of the sensitivity of the gel material is necessary for the high-dose signals to be collected at a certain signal-to-noise ratio. Results obtained using the optimized CT scanning approach are compared with those from the treatment planning system and the film measurement.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12945992     DOI: 10.1118/1.1593837

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Characterization of a new radiochromic three-dimensional dosimeter.

Authors:  P Y Guo; J A Adamovics; M Oldham
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  Optical-CT scanning of polymer gels.

Authors:  M Oldham
Journal:  J Phys Conf Ser       Date:  2004

3.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

4.  3D dosimetry by optical-CT scanning.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2006

5.  An investigation of the accuracy of an IMRT dose distribution using two- and three-dimensional dosimetry techniques.

Authors:  Mark Oldham; Harshad Sakhalkar; Pengyi Guo; John Adamovics
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

6.  Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters.

Authors:  Y Xu; Cheng-Shie Wuu; Marek J Maryanski
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

7.  Investigations into the feasibility of optical-CT 3D dosimetry with minimal use of refractively matched fluids.

Authors:  Kelsey Chisholm; Devin Miles; Leith Rankine; Mark Oldham
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

Review 8.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

9.  Effect of composition interactions on the dose response of an N-isopropylacrylamide gel dosimeter.

Authors:  Yuan-Jen Chang; Bor-Tsung Hsieh
Journal:  PLoS One       Date:  2012-10-12       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.