Literature DB >> 18541485

Adaptive SPECT.

Harrison H Barrett1, Lars R Furenlid, Melanie Freed, Jacob Y Hesterman, Matthew A Kupinski, Eric Clarkson, Meredith K Whitaker.   

Abstract

Adaptive imaging systems alter their data-acquisition configuration or protocol in response to the image information received. An adaptive pinhole single-photon emission computed tomography (SPECT) system might acquire an initial scout image to obtain preliminary information about the radiotracer distribution and then adjust the configuration or sizes of the pinholes, the magnifications, or the projection angles in order to improve performance. This paper briefly describes two small-animal SPECT systems that allow this flexibility and then presents a framework for evaluating adaptive systems in general, and adaptive SPECT systems in particular. The evaluation is in terms of the performance of linear observers on detection or estimation tasks. Expressions are derived for the ideal linear (Hotelling) observer and the ideal linear (Wiener) estimator with adaptive imaging. Detailed expressions for the performance figures of merit are given, and possible adaptation rules are discussed.

Mesh:

Year:  2008        PMID: 18541485      PMCID: PMC2575754          DOI: 10.1109/TMI.2007.913241

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  28 in total

Review 1.  Advances in ultrasound.

Authors:  Michel Claudon; François Tranquart; David H Evans; Frédéric Lefèvre; Michel Correas
Journal:  Eur Radiol       Date:  2001-12-14       Impact factor: 5.315

2.  Adaptive imaging using the generalized coherence factor.

Authors:  Pai-Chi Li; Meng-Lin Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-02       Impact factor: 2.725

3.  Experimental determination of object statistics from noisy images.

Authors:  Matthew A Kupinski; Eric Clarkson; John W Hoppin; Liying Chen; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2003-03       Impact factor: 2.129

4.  Computed tomography sound velocity reconstruction using incomplete data.

Authors:  Sheng-Wen Huang; Pai-Chi Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-03       Impact factor: 2.725

Review 5.  Small animal SPECT and its place in the matrix of molecular imaging technologies.

Authors:  Steven R Meikle; Peter Kench; Michael Kassiou; Richard B Banati
Journal:  Phys Med Biol       Date:  2005-10-24       Impact factor: 3.609

6.  Adaptive imaging using an optimal receive aperture size.

Authors:  Meng-Lin Li; Sheng-Wen Huang; Kutay Ustüner; Pai-Chi Li
Journal:  Ultrason Imaging       Date:  2005-04       Impact factor: 1.578

7.  A multipinhole small animal SPECT system with submillimeter spatial resolution.

Authors:  Tobias Funk; Philippe Després; William C Barber; Kanai S Shah; Bruce H Hasegawa
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

8.  A speckle target adaptive imaging technique in the presence of distributed aberrations.

Authors:  G C Ng; P D Freiburger; W F Walker; G E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1997       Impact factor: 2.725

9.  Applicability and efficiency of near-optimal spatial encoding for dynamically adaptive MRI.

Authors:  G P Zientara; L P Panych; F A Jolesz
Journal:  Magn Reson Med       Date:  1998-02       Impact factor: 4.668

10.  Dynamically adaptive MRI with encoding by singular value decomposition.

Authors:  G P Zientara; L P Panych; F A Jolesz
Journal:  Magn Reson Med       Date:  1994-08       Impact factor: 4.668

View more
  42 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  Adaptive CT for High-Resolution, Controlled-Dose, Region-of-Interest Imaging.

Authors:  Jared W Moore; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009

3.  C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential.

Authors:  Wei Chang; Caesar E Ordonez; Haoning Liang; Yusheng Li; Jingai Liu
Journal:  IEEE Trans Nucl Sci       Date:  2009-10-06       Impact factor: 1.679

Review 4.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

5.  ADAPTIVE SMALL-ANIMAL SPECT/CT.

Authors:  L R Furenlid; J W Moore; M Freed; M A Kupinski; E Clarkson; Z Liu; D W Wilson; J M Woolfenden; H H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2008

6.  Joint optimization of collimator and reconstruction parameters in SPECT imaging for lesion quantification.

Authors:  Sarah J McQuaid; Sudeepti Southekal; Marie Foley Kijewski; Stephen C Moore
Journal:  Phys Med Biol       Date:  2011-11-07       Impact factor: 3.609

7.  A Task-Based Approach to Adaptive and Multimodality Imaging: Computation techniques are proposed for figures-of-merit to establish feasibility and optimize use of multiple imaging systems for disease diagnosis and treatment-monitoring.

Authors:  Eric Clarkson; Matthew A Kupinski; Harrison H Barrett; Lars Furenlid
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2008-03       Impact factor: 10.961

Review 8.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

9.  Scanning linear estimation: improvements over region of interest (ROI) methods.

Authors:  Meredith K Kupinski; Eric W Clarkson; Harrison H Barrett
Journal:  Phys Med Biol       Date:  2013-02-06       Impact factor: 3.609

10.  SPECT system optimization against a discrete parameter space.

Authors:  L J Meng; N Li
Journal:  Phys Med Biol       Date:  2013-04-15       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.