Literature DB >> 23885129

C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential.

Wei Chang1, Caesar E Ordonez, Haoning Liang, Yusheng Li, Jingai Liu.   

Abstract

Because of scarcity of photons emitted from the heart, clinical cardiac SPECT imaging is mainly limited by photon statistics. The sub-optimal detection efficiency of current SPECT systems not only limits the quality of clinical cardiac SPECT imaging but also makes more advanced potential applications difficult to be realized. We propose a high-performance system platform - C-SPECT, which has its sampling geometry optimized for detection of emitted photons in quality and quantity. The C-SPECT has a stationary C-shaped gantry that surrounds the left-front side of a patient's thorax. The stationary C-shaped collimator and detector systems in the gantry provide effective and efficient detection and sampling of photon emission. For cardiac imaging, the C-SPECT platform could achieve 2 to 4 times the system geometric efficiency of conventional SPECT systems at the same sampling resolution. This platform also includes an integrated transmission CT for attenuation correction. The ability of C-SPECT systems to perform sequential high-quality emission and transmission imaging could bring cost-effective high-performance to clinical imaging. In addition, a C-SPECT system could provide high detection efficiency to accommodate fast acquisition rate for gated and dynamic cardiac imaging. This paper describes the design concepts and performance potential of C-SPECT, and illustrates how these concepts can be implemented in a basic system.

Entities:  

Keywords:  Cardiovascular system; SPECT; imaging; instrumentation; system analysis and design

Year:  2009        PMID: 23885129      PMCID: PMC3718566          DOI: 10.1109/TNS.2009.2028138

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  38 in total

1.  American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: attenuation correction of myocardial perfusion SPECT scintigraphy.

Authors:  Gary V Heller; Jonathan Links; Timothy M Bateman; Jack A Ziffer; Edward Ficaro; Mylan C Cohen; Robert C Hendel
Journal:  J Nucl Cardiol       Date:  2004 Mar-Apr       Impact factor: 5.952

2.  Recent technologic advances in nuclear cardiology.

Authors:  James A Patton; Piotr J Slomka; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

3.  Verification of the sensitivity and resolution dependence on the incidence angle for slit-slat collimation.

Authors:  J R Novak; A S Ayan; R Accorsi; S D Metzler
Journal:  Phys Med Biol       Date:  2008-01-23       Impact factor: 3.609

4.  Cone beam tomography of the heart using single-photon emission-computed tomography.

Authors:  G T Gullberg; P E Christian; G L Zeng; F L Datz; H T Morgan
Journal:  Invest Radiol       Date:  1991-07       Impact factor: 6.016

5.  Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease.

Authors:  Peter P Steele; Dennis L Kirch; John E Koss
Journal:  J Nucl Med       Date:  2008-06-13       Impact factor: 10.057

Review 6.  Transmission scanning in emission tomography.

Authors:  D L Bailey
Journal:  Eur J Nucl Med       Date:  1998-07

7.  Correction of nonuniform attenuation in cardiac SPECT imaging.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; J G Ballard; J R Perry; W H McCartney; J Berg
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

8.  Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection.

Authors:  R J Jaszczak; C E Floyd; S H Manglos; K L Greer; R E Coleman
Journal:  Med Phys       Date:  1986 Jul-Aug       Impact factor: 4.071

9.  Effect of tungsten absorption edge filter on diagnostic x-ray spectra, image quality and absorbed dose to the patient.

Authors:  C Yamaguchi; T Yamamoto; H Terada; M Akisada
Journal:  Phys Med Biol       Date:  1983-03       Impact factor: 3.609

Review 10.  Clinical review of attenuation-corrected cardiac SPECT.

Authors:  J R Corbett; E P Ficaro
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

View more
  6 in total

1.  Analytic derivation of pinhole collimation sensitivity for a general source model using spherical harmonics.

Authors:  Yu-Sheng Li; James E Oldendick; Wei Chang
Journal:  Phys Med Biol       Date:  2010-04-19       Impact factor: 3.609

Review 2.  Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Authors:  Karen Van Audenhaege; Roel Van Holen; Stefaan Vandenberghe; Christian Vanhove; Scott D Metzler; Stephen C Moore
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

Review 3.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

4.  Collimator Interchange System for Adaptive Cardiac Imaging in C-SPECT.

Authors:  Mike Rozler; Wei Chang
Journal:  IEEE Trans Nucl Sci       Date:  2010       Impact factor: 1.679

5.  Finding Optimized Conditions of Slit-Slat and Multislit-Slat Collimation for Breast Imaging.

Authors:  Daekwang Kau; Scott D Metzler
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-01       Impact factor: 1.679

6.  Development of a Cost-Effective Modular Pixelated NaI(Tl) Detector for Clinical SPECT Applications.

Authors:  Mike Rozler; Haoning Liang; Wei Chang
Journal:  IEEE Trans Nucl Sci       Date:  2012-08-30       Impact factor: 1.679

  6 in total