Insertional torque and axial pull-out strength of mini-implants in mandibles of dogs.

Karine Kimak Salmória1, Orlando Motohiro Tanaka, Odilon Guariza-Filho, Elisa Souza Camargo, Leandro Teixeira de Souza, Hiroshi Maruo.   

Abstract

INTRODUCTION: The objectives of this study were to evaluate insertional torque of mini-implants (MI) for orthodontic anchorage, to compare their axial pull-out strength at 0 (T0), 15 (T15), and 60 (T60) days after placement, to determine initial and peri-implant cortical bone thickness, and to analyze the correlations among these variables.
METHODS: Sixty MI were placed in the mandibles of 10 dogs. Peak insertional torque values were recorded, and, after the animals were killed, specimens were prepared. The MI were aligned with a testing machine to register axial pull-out strength. Cortical bone thickness was measured after removal of the MI. Statistical analyses were conducted with ANOVA and Tukey HSD tests.
RESULTS: Pull-out strength and peri-implant cortical bone thickness had differences (P <0.01) at the various times. The T0 value showed the highest pull-out strength, and the smallest peri-implant cortical bone thickness was at T60. There was a regular correlation between pull-out strength and peri-implant cortical bone thickness at T0 (r = 0.44, P = 0.05). There was no correlation between insertional torque and pull-out strength, and insertional torque and initial cortical bone thickness.
CONCLUSIONS: Pull-out strength is greater immediately after placement of MI, cortical bone thickness decreases because of bone resorption, and insertional torque is not an efficient method for predicting the retention of MI.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18538236     DOI: 10.1016/j.ajodo.2007.12.020

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  17 in total

1.  Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study.

Authors:  Aniruddh V Yashwant; S Dilip; R Krishnaraj; K Ravi
Journal:  J Clin Diagn Res       Date:  2017-05-01

2.  Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device.

Authors:  Yasuhiko Oga; Hiroshi Tomonari; Sangho Kwon; Takaharu Kuninori; Takakazu Yagi; Shouichi Miyawaki
Journal:  Angle Orthod       Date:  2018-09-01       Impact factor: 2.079

Review 3.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

4.  Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy.

Authors:  Giselle Naback Lemes Vilani; Antônio Carlos de Oliveira Ruellas; Carlos Nelson Elias; Cláudia Trindade Mattos
Journal:  Dental Press J Orthod       Date:  2015-10

5.  Factors affecting stresses in cortical bone around miniscrew implants: a three-dimensional finite element study.

Authors:  Ramzi Duaibis; Budi Kusnoto; Raghu Natarajan; Linping Zhao; Carla Evans
Journal:  Angle Orthod       Date:  2012-03-05       Impact factor: 2.079

6.  Effects of cortical bone thickness at different healing times on microscrew stability.

Authors:  Xing Wei; Lixing Zhao; Zhenrui Xu; Tian Tang; Zhihe Zhao
Journal:  Angle Orthod       Date:  2011-05-02       Impact factor: 2.079

7.  Effect of placement angle on the stability of loaded titanium microscrews in beagle jaws.

Authors:  Zhenrui Xu; Yeke Wu; Lixing Zhao; Yuqiao Zhou; Xing Wei; Na Tang; Xiaoxia Feng; Tian Tang; Zhihe Zhao
Journal:  Angle Orthod       Date:  2012-12-10       Impact factor: 2.079

8.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

9.  An in vitro study of factors affecting the primary stability of orthodontic mini-implants.

Authors:  Lindsy Holm; Susan J Cunningham; Aviva Petrie; Richard R J Cousley
Journal:  Angle Orthod       Date:  2012-05-07       Impact factor: 2.079

Review 10.  Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.

Authors:  Mariana Marquezan; Cláudia Trindade Mattos; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza; Lucianne Cople Maia
Journal:  Angle Orthod       Date:  2014-04-02       Impact factor: 2.079