Literature DB >> 28658900

Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study.

Aniruddh V Yashwant1, S Dilip2, R Krishnaraj2, K Ravi3.   

Abstract

INTRODUCTION: Mini implants form a valuable source for absolute anchorage thereby helping in achieving ideal treatment outcome. Stability of the mini implant is one of the important factors affecting the success of mini implants. Thread shape is a critical factor in the engineering design of mini implant, which affects the primary stability. AIM: To evaluate the effects of thread shape on the pull out strength of mini implants.
MATERIALS AND METHODS: Mini implants of five different designs in thread shape (reverse buttress, buttress, 75° joint profile with flutes, trapezoidal and trapezoidal fluted) were used with 10 screws in each group. The mini implants were loaded on to the polyurethane foam block (Sawbones pacific research lab, USA) perpendicular to the surface and the pull out strength was tested using the Instrom testing machine. The control group consisted of mini implants with reverse buttress thread shape. One-way ANOVA and Tukey post-hoc tests were used to compare the pull out strength of the mini implants within as well as between the different groups.
RESULTS: The mean in the pull out tests ranged from 13.45 N (trapezoidal) to 61 N (trapezoidal fluted). The tukey post-hoc tests showed a statistically significant difference of 34.5 N between the control group and the trapezoidal fluted group. The level of statistical significance showed p< 0.05.
CONCLUSION: Trapezoidal fluted mini implants showed the highest pull out strength when compared to mini implants with other thread designs used in this study. Further studies with the use of Finite Element Method (FEM) and foam blocks of higher density would be required to evaluate the performance of this new thread design.

Entities:  

Keywords:  Anchorage; Stability; Trapezoidal fluted

Year:  2017        PMID: 28658900      PMCID: PMC5483802          DOI: 10.7860/JCDR/2017/25774.9808

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  27 in total

1.  Mechanical tests and finite element models for bone holding power of tibial locking screws.

Authors:  Sheng-Mou Hou; Ching-Chi Hsu; Jaw-Lin Wang; Ching-Kong Chao; Jinn Lin
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-08       Impact factor: 2.063

2.  Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort.

Authors:  Shingo Kuroda; Yasuyo Sugawara; Toru Deguchi; Hee-Moon Kyung; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-01       Impact factor: 2.650

3.  Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Tohru Yoshida; Akiko Ono; Noriyoshi Shimizu
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Sep-Oct       Impact factor: 2.804

4.  Impact of implant design on primary stability of orthodontic mini-implants.

Authors:  Benedict Wilmes; Stephanie Ottenstreuer; Yu-Yu Su; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2008-01       Impact factor: 1.938

5.  Segmental intrusion with mini-screw implant anchorage: a radiographic evaluation.

Authors:  Roberto Carrillo; Peter H Buschang; Lynne A Opperman; Pedro F Franco; P Emile Rossouw
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-11       Impact factor: 2.650

6.  Insertional torque and axial pull-out strength of mini-implants in mandibles of dogs.

Authors:  Karine Kimak Salmória; Orlando Motohiro Tanaka; Odilon Guariza-Filho; Elisa Souza Camargo; Leandro Teixeira de Souza; Hiroshi Maruo
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-06       Impact factor: 2.650

7.  Temporary anchorage device stability: an evaluation of thread shape factor.

Authors:  M Migliorati; A Signori; A Silvestrini-Biavati
Journal:  Eur J Orthod       Date:  2011-03-02       Impact factor: 3.075

8.  Effect of specimen fixation method on pullout tests of pedicle screws.

Authors:  M Pfeiffer; L G Gilbertson; V K Goel; P Griss; J C Keller; T C Ryken; H E Hoffman
Journal:  Spine (Phila Pa 1976)       Date:  1996-05-01       Impact factor: 3.468

9.  Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage.

Authors:  Jong-Wan Kim; Sug-Joon Ahn; Young-Il Chang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-08       Impact factor: 2.650

10.  Miniscrews as orthodontic anchorage: a preliminary report.

Authors:  A Costa; M Raffainl; B Melsen
Journal:  Int J Adult Orthodon Orthognath Surg       Date:  1998
View more
  1 in total

Review 1.  Application of Finite Element Model in Implant Dentistry: A Systematic Review.

Authors:  M Sesha Reddy; Rajasekar Sundram; Hossam Abdelatty Eid Abdemagyd
Journal:  J Pharm Bioallied Sci       Date:  2019-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.