Literature DB >> 20070743

Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Po-Chun Chang1, Niklaus P Lang, William V Giannobile.   

Abstract

OBJECTIVES: The aim of this paper is to review current investigations on functional assessments of osseointegration and assess correlations to the peri-implant structure.
MATERIAL AND METHODS: The literature was electronically searched for studies of promoting dental implant osseointegration, functional assessments of implant stability, and finite element (FE) analyses in the field of implant dentistry, and any references regarding biological events during osseointegration were also cited as background information.
RESULTS: Osseointegration involves a cascade of protein and cell apposition, vascular invasion, de novo bone formation and maturation to achieve the primary and secondary dental implant stability. This process may be accelerated by alteration of the implant surface roughness, developing a biomimetric interface, or local delivery of growth-promoting factors. The current available pre-clinical and clinical biomechanical assessments demonstrated a variety of correlations to the peri-implant structural parameters, and functionally integrated peri-implant structure through FE optimization can offer strong correlation to the interfacial biomechanics.
CONCLUSIONS: The progression of osseointegration may be accelerated by alteration of the implant interface as well as growth factor applications, and functional integration of peri-implant structure may be feasible to predict the implant function during osseointegration. More research in this field is still needed.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20070743      PMCID: PMC2808201          DOI: 10.1111/j.1600-0501.2009.01826.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  144 in total

1.  A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study.

Authors:  B Friberg; L Sennerby; N Meredith; U Lekholm
Journal:  Int J Oral Maxillofac Surg       Date:  1999-08       Impact factor: 2.789

2.  Trabecular bone's mechanical properties are affected by its non-uniform mineral distribution.

Authors:  J C van der Linden; D H Birkenhäger-Frenkel; J A Verhaar; H Weinans
Journal:  J Biomech       Date:  2001-12       Impact factor: 2.712

3.  Recombinant human bone morphogenetic protein-2 stimulation of bone formation around endosseous dental implants.

Authors:  D L Cochran; R Schenk; D Buser; J M Wozney; A A Jones
Journal:  J Periodontol       Date:  1999-02       Impact factor: 6.993

4.  Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Tohru Yoshida; Akiko Ono; Noriyoshi Shimizu
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Sep-Oct       Impact factor: 2.804

5.  Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.

Authors:  D Buser; R K Schenk; S Steinemann; J P Fiorellini; C H Fox; H Stich
Journal:  J Biomed Mater Res       Date:  1991-07

6.  Implant surfaces and design (Working Group 4).

Authors:  Niklaus P Lang; Søren Jepsen
Journal:  Clin Oral Implants Res       Date:  2009-09       Impact factor: 5.977

Review 7.  Periotest to monitor osseointegration and to check the occlusion in oral implantology.

Authors:  W Schulte; D Lukas
Journal:  J Oral Implantol       Date:  1993       Impact factor: 1.779

Review 8.  Growth factors in periodontal regeneration.

Authors:  D T Graves; Y M Kang; K N Kose
Journal:  Compend Suppl       Date:  1994

9.  Additive enhancement of implant fixation following combined treatment with rhTGF-beta2 and rhBMP-2 in a canine model.

Authors:  D R Sumner; T M Turner; R M Urban; A S Virdi; N Inoue
Journal:  J Bone Joint Surg Am       Date:  2006-04       Impact factor: 5.284

10.  Surface energy characterization of unalloyed titanium implants.

Authors:  D V Kilpadi; J E Lemons
Journal:  J Biomed Mater Res       Date:  1994-12
View more
  18 in total

1.  Comparative assessment of the interfacial soft and hard tissues investing implants and natural teeth in the macaque mandible.

Authors:  Chong Huat Siar; Chooi Gait Toh; Georgios E Romanos; Kok Han Ng
Journal:  Clin Oral Investig       Date:  2014-11-21       Impact factor: 3.573

2.  Inflammatory cytokine release is affected by surface morphology and chemistry of titanium implants.

Authors:  Anna-Karin Östberg; Ulf Dahlgren; Young-Taeg Sul; Carina B Johansson
Journal:  J Mater Sci Mater Med       Date:  2015-03-17       Impact factor: 3.896

3.  Highly Nonlinear Solitary Waves for the Assessment of Dental Implant Mobility.

Authors:  Bruk Berhanu; Piervincenzo Rizzo; Mark Ochs
Journal:  J Appl Mech       Date:  2012-11-20       Impact factor: 2.168

4.  Sequential platelet-derived growth factor-simvastatin release promotes dentoalveolar regeneration.

Authors:  Po-Chun Chang; Li Yen Chong; Alex S M Dovban; Lum Peng Lim; Jason C Lim; Mark Yen-Ping Kuo; Chi-Hwa Wang
Journal:  Tissue Eng Part A       Date:  2013-10-17       Impact factor: 3.845

5.  High-frequency loading positively impacts titanium implant osseointegration in impaired bone.

Authors:  M Chatterjee; K Hatori; J Duyck; K Sasaki; I Naert; K Vandamme
Journal:  Osteoporos Int       Date:  2014-08-28       Impact factor: 4.507

6.  Heat and radiofrequency plasma glow discharge pretreatment of a titanium alloy promote bone formation and osseointegration.

Authors:  Daniel E MacDonald; Bruce E Rapuano; Parth Vyas; Joseph M Lane; Kathleen Meyers; Timothy Wright
Journal:  J Cell Biochem       Date:  2013-10       Impact factor: 4.429

7.  Association between implant apex and sinus floor in posterior maxilla dental implantation: A three-dimensional finite element analysis.

Authors:  Xu Yan; Xinwen Zhang; Weichao Chi; Hongjun Ai; Lin Wu
Journal:  Exp Ther Med       Date:  2015-01-22       Impact factor: 2.447

Review 8.  Micromotions and combined damages at the dental implant/bone interface.

Authors:  Shan-Shan Gao; Ya-Rong Zhang; Zhuo-Li Zhu; Hai-Yang Yu
Journal:  Int J Oral Sci       Date:  2012-12-21       Impact factor: 6.344

9.  The influence of surface treatment on the implant roughness pattern.

Authors:  Marcio Borges Rosa; Tomas Albrektsson; Carlos Eduardo Francischone; Humberto Osvaldo Schwartz Filho; Ann Wennerberg
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

10.  Improvement of Osseointegration by Ultraviolet and/or Simvastatin Treatment on Titanium Implants with or without Bone Graft Materials.

Authors:  Ji Hoon Jun; Kyung Chul Oh; Kyu-Hyung Park; Narae Jung; Jiayi Li; Hong Seok Moon
Journal:  Materials (Basel)       Date:  2021-07-02       Impact factor: 3.623

View more