Literature DB >> 26560819

Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy.

Giselle Naback Lemes Vilani1, Antônio Carlos de Oliveira Ruellas2, Carlos Nelson Elias3, Cláudia Trindade Mattos4.   

Abstract

OBJECTIVE: To compare in vivo orthodontic mini-implants (MI) of smooth (machined) and rough (acid etched) surfaces, assessing primary and secondary stability.
METHODS: Thirty-six (36) MI were inserted in the mandibles of six (6) dogs. Each animal received six (6) MI. In the right hemiarch, three (3) MI without surface treatment (smooth) were inserted, whereas in the left hemiarch, another three (3) MI with acid etched surfaces (rough) were inserted. The two distal MI in each hemiarch received an immediate load of 1.0 N for 16 weeks, whereas the MI in the mesial extremity was not subject to loading. Stability was measured by insertion and removal torque, initial and final mobility and by inter mini-implant distance.
RESULTS: There was no statistical behavioral difference between smooth and rough MI. High insertion torque and reduced initial mobility were observed in all groups, as well as a reduction in removal torques in comparison with insertion torque. Rough MI presented higher removal torque and lower final mobility in comparison to smooth MI. MI did not remain static, with displacement of rough MI being smaller in comparison with smooth MI, but with no statistical difference.
CONCLUSIONS: MI primary stability was greater than stability measured at removal. There was no difference in stability between smooth and rough MI when assessing mobility, displacement and insertion as well as removal torques.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26560819      PMCID: PMC4644917          DOI: 10.1590/2177-6709.20.5.035-042.oar

Source DB:  PubMed          Journal:  Dental Press J Orthod        ISSN: 2176-9451


  30 in total

1.  Intrusion of posterior teeth using mini-screw implants.

Authors:  Young-Chel Park; Seung-Yeon Lee; Doo-Hyung Kim; Sung-Hoon Jee
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-06       Impact factor: 2.650

2.  In vitro evaluation of insertion and removal torques of orthodontic mini-implants.

Authors:  M M Pithon; M G Nojima; L I Nojima
Journal:  Int J Oral Maxillofac Surg       Date:  2010-11-02       Impact factor: 2.789

3.  Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque.

Authors:  Carlos Nelson Elias; Yoshiki Oshida; José Henrique Cavalcanti Lima; Carlos Alberto Muller
Journal:  J Mech Behav Biomed Mater       Date:  2007-12-31

4.  Rotational resistance of surface-treated mini-implants.

Authors:  Seong-Hun Kim; Shin-Jae Lee; Il-Sik Cho; Seong-Kyun Kim; Tae-Woo Kim
Journal:  Angle Orthod       Date:  2009-09       Impact factor: 2.079

5.  Placement and removal torque values of orthodontic miniscrew implants.

Authors:  Eduardo Yugo Suzuki; Boonsiva Suzuki
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-05       Impact factor: 2.650

6.  Three-dimensional analysis of peri-bone-implant contact of rough-surface miniscrew implants.

Authors:  Hedeki Ikeda; P Emile Rossouw; Phillip M Campbell; Elias Kontogiorgos; Elias Kontogirogos; Peter H Buschang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-02       Impact factor: 2.650

7.  Survival analysis of orthodontic mini-implants.

Authors:  Shin-Jae Lee; Sug-Joon Ahn; Jae Won Lee; Seong-Hun Kim; Tae-Woo Kim
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-02       Impact factor: 2.650

8.  Long-term evaluation of sandblasted and acid-etched implants used as orthodontic anchors in dogs.

Authors:  Musa Aldikaçti; Gökhan Açikgöz; Tamer Türk; Paolo Trisi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2004-02       Impact factor: 2.650

9.  Stability of immediately loaded 3- and 6-mm miniscrew implants in beagle dogs--a pilot study.

Authors:  Micah G Mortensen; Peter H Buschang; Donald R Oliver; Hee-Moon Kyung; Rolf G Behrents
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-08       Impact factor: 2.650

10.  Resistance to immediate orthodontic loading of surface-treated mini-implants.

Authors:  Sung-Seo Mo; Seong-Hun Kim; Yoon-Ah Kook; Do-Min Jeong; Kyu-Rhim Chung; Gerald Nelson
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

View more
  1 in total

1.  Effect of surface treatment on the mechanical stability of orthodontic miniscrews.

Authors:  Yousef Al-Thomali; Sakeenabi Basha; Roshan Noor Mohamed
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

  1 in total