Literature DB >> 24694015

Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.

Mariana Marquezan1, Cláudia Trindade Mattos, Eduardo Franzotti Sant'Anna, Margareth Maria Gomes de Souza, Lucianne Cople Maia.   

Abstract

OBJECTIVE: To investigate whether there is evidence to support the association between cortical thickness (CtTh) and the primary stability of mini-implants (MI).
MATERIALS AND METHODS: A search was performed including articles published until September 2013. The inclusion criteria comprised observational clinical studies conducted in patients who received monocortical MI for orthodontic anchorage and in vivo or ex vivo experimental studies performed to evaluate the primary stability of MI, studies that evaluated the association between CtTh and MI primary stability, CtTh measurement performed numerically, and MI primary stability evaluated by implant stability quotient value, Periotest value , pull-out strength, or insertion torque. Studies conducted exclusively in artificial bone or finite elements were excluded.
RESULTS: Abstract and title reading identified 15 possible articles to be included. After reading the complete text, three were excluded. One article was found by hand searching and another excluded for an overlapping sample. Finally, 12 articles were selected. A positive correlation was found between primary stability and CtTh when studies that evaluated primary stability through PS were grouped (r  =  .409) and when studies that evaluated stability in humans were grouped (r  =  .338).
CONCLUSIONS: There is a positive association between MI primary stability and CtTh of the receptor site. However, there is still a lack of well-designed clinical trials.

Entities:  

Keywords:  Cortical thickness; Mini-implant; Miniscrew; Stability

Mesh:

Substances:

Year:  2014        PMID: 24694015      PMCID: PMC8638503          DOI: 10.2319/093013-716.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  28 in total

1.  A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage.

Authors:  Shih-Jung Cheng; I-Yun Tseng; Jang-Jaer Lee; Sang-Heng Kok
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Jan-Feb       Impact factor: 2.804

2.  Meta-analysis of methods used to assess implant stability.

Authors:  Murat Cavit Cehreli; Durdu Karasoy; Kivanc Akca; Steven E Eckert
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Nov-Dec       Impact factor: 2.804

Review 3.  The role of primary stability for successful immediate loading of dental implants. A literature review.

Authors:  Fawad Javed; George E Romanos
Journal:  J Dent       Date:  2010-06-11       Impact factor: 4.379

4.  Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Tohru Yoshida; Akiko Ono; Noriyoshi Shimizu
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Sep-Oct       Impact factor: 2.804

5.  Cortical bone strains around straight and angulated immediate orthodontic microimplants: a pilot study.

Authors:  Secil Cehreli; Alev Yilmaz; Ayca Arman-Ozcirpici
Journal:  Implant Dent       Date:  2013-04       Impact factor: 2.454

6.  Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs.

Authors:  Sarandeep S Huja; Alan S Litsky; F Mike Beck; Kenneth A Johnson; Peter E Larsen
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-03       Impact factor: 2.650

7.  Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications.

Authors:  J W Freudenthaler; R Haas; H P Bantleon
Journal:  Clin Oral Implants Res       Date:  2001-08       Impact factor: 5.977

8.  Application of a wireless resonance frequency transducer to assess primary stability of orthodontic mini-implants: an in vitro study in pig ilia.

Authors:  Yu-Yu Su; Benedict Wilmes; Ralf Hönscheid; Dieter Drescher
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Jul-Aug       Impact factor: 2.804

Review 9.  Insertion torque and success of orthodontic mini-implants: a systematic review.

Authors:  Reint A Meursinge Reynders; Laura Ronchi; Luisa Ladu; Faridi van Etten-Jamaludin; Shandra Bipat
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-11       Impact factor: 2.650

10.  Measurement of mini-implant stability using resonance frequency analysis.

Authors:  Manuel Nienkemper; Benedict Wilmes; Agamemnon Panayotidis; Alexander Pauls; Vladimir Golubovic; Frank Schwarz; Dieter Drescher
Journal:  Angle Orthod       Date:  2012-08-29       Impact factor: 2.079

View more
  18 in total

1.  Analysis of biological and structural factors implicated in the clinical success of orthodontic miniscrews at posterior maxillary interradicular sites.

Authors:  M Palone; A Darsiè; G B Maino; G Siciliani; G A Spedicato; L Lombardo
Journal:  Clin Oral Investig       Date:  2021-11-27       Impact factor: 3.573

2.  Anatomical study of the maxillary tuberosity using cone beam computed tomography.

Authors:  Ester Manzanera; Paula Llorca; David Manzanera; Verónica García-Sanz; Vicente Sada; Vanessa Paredes-Gallardo
Journal:  Oral Radiol       Date:  2017-04-06       Impact factor: 1.852

3.  A study of success rate of miniscrew implants as temporary anchorage devices in singapore.

Authors:  Song Yi Lin; Yow Mimi; Chew Ming Tak; Foong Kelvin Weng Chiong; Wong Hung Chew
Journal:  Int J Dent       Date:  2015-03-10

4.  Evaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study.

Authors:  Massoud Seifi; Negin-Sadat Matini
Journal:  J Clin Exp Dent       Date:  2016-07-01

5.  Influence of Screw Length and Bone Thickness on the Stability of Temporary Implants.

Authors:  Daniel Jogaib Fernandes; Carlos Nelson Elias; Antônio Carlos de Oliveira Ruellas
Journal:  Materials (Basel)       Date:  2015-09-23       Impact factor: 3.623

6.  Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study.

Authors:  Jacek Matys; Rafał Flieger; Gianluca Tenore; Kinga Grzech-Leśniak; Umberto Romeo; Marzena Dominiak
Journal:  Lasers Med Sci       Date:  2017-11-10       Impact factor: 3.161

7.  Sex-, growth pattern-, and growth status-related variability in maxillary and mandibular buccal cortical thickness and density.

Authors:  Sydney Schneider; Vaibhav Gandhi; Madhur Upadhyay; Veerasathpurush Allareddy; Aditya Tadinada; Sumit Yadav
Journal:  Korean J Orthod       Date:  2020-03-24       Impact factor: 1.372

8.  Effect of 808 nm Semiconductor Laser on the Stability of Orthodontic Micro-Implants: A Split-Mouth Study.

Authors:  Jacek Matys; Rafał Flieger; Tomasz Gedrange; Krzysztof Janowicz; Bartosz Kempisty; Kinga Grzech-Leśniak; Marzena Dominiak
Journal:  Materials (Basel)       Date:  2020-05-14       Impact factor: 3.623

9.  Safe regions of miniscrew implantation for distalization of mandibular dentition with CBCT.

Authors:  Haibo Liu; Xiaoxue Wu; Jun Tan; Xiao Li
Journal:  Prog Orthod       Date:  2019-12-09       Impact factor: 2.750

10.  Effects of cortical bone thickness and trabecular bone density on primary stability of orthodontic mini-implants.

Authors:  Chin-Yun Pan; Pao-Hsin Liu; Yu-Chuan Tseng; Szu-Ting Chou; Chao-Yi Wu; Hong-Po Chang
Journal:  J Dent Sci       Date:  2019-07-20       Impact factor: 2.080

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.