Literature DB >> 18429011

Adaptive 4D MR imaging using navigator-based respiratory signal for MRI-guided therapy.

Junichi Tokuda1, Shigehiro Morikawa, Hasnine A Haque, Tetsuji Tsukamoto, Kiyoshi Matsumiya, Hongen Liao, Ken Masamune, Takeyoshi Dohi.   

Abstract

For real-time 3D visualization of respiratory organ motion for MRI-guided therapy, a new adaptive 4D MR imaging method based on navigator echo and multiple gating windows was developed. This method was designed to acquire a time series of volumetric 3D images of a cyclically moving organ, enabling therapy to be guided by synchronizing the 4D image with the actual organ motion in real time. The proposed method was implemented in an open-configuration 0.5T clinical MR scanner. To evaluate the feasibility and determine optimal imaging conditions, studies were conducted with a phantom, volunteers, and a patient. In the phantom study the root mean square (RMS) position error in the 4D image of the cyclically moving phantom was 1.9 mm and the imaging time was approximately 10 min when the 4D image had six frames. In the patient study, 4D images were successfully acquired under clinical conditions and a liver tumor was discriminated in the series of frames. The image quality was affected by the relations among the encoding direction, the slice orientation, and the direction of motion of the target organ. In conclusion, this study has shown that the proposed method is feasible and capable of providing a real-time dynamic 3D atlas for surgical navigation with sufficient accuracy and image quality. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18429011      PMCID: PMC3004024          DOI: 10.1002/mrm.21436

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Truly hybrid interventional MR/X-ray system: investigation of in vivo applications.

Authors:  R Fahrig; K Butts; Z Wen; R Saunders; S T Kee; D Y Sze; B L Daniel; F Laerum; N J Pelc
Journal:  Acad Radiol       Date:  2001-12       Impact factor: 3.173

2.  Simultaneous multiple volume (SMV) acquisition algorithm for real-time navigator gating.

Authors:  Vladimir N Kolmogorov; Richard Watts; Martin R Prince; Ramin Zabih; Yi Wang
Journal:  Magn Reson Imaging       Date:  2003-11       Impact factor: 2.546

3.  A hybrid breast biopsy system combining ultrasound and MRI.

Authors:  C A Piron; P Causer; R Jong; R Shumak; D B Plewes
Journal:  IEEE Trans Med Imaging       Date:  2003-09       Impact factor: 10.048

4.  Ultrasound-guided MRI: preliminary results using a motion phantom.

Authors:  Matthias Günther; David A Feinberg
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

5.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

6.  Adaptive technique for high-definition MR imaging of moving structures.

Authors:  R L Ehman; J P Felmlee
Journal:  Radiology       Date:  1989-10       Impact factor: 11.105

7.  Assessment of hepatic respiratory excursion.

Authors:  P H Weiss; J M Baker; E J Potchen
Journal:  J Nucl Med       Date:  1972-10       Impact factor: 10.057

8.  MR-guided focused ultrasound surgery (MRgFUS) for the palliation of pain in patients with bone metastases--preliminary clinical experience.

Authors:  R Catane; A Beck; Y Inbar; T Rabin; N Shabshin; S Hengst; R M Pfeffer; A Hanannel; O Dogadkin; B Liberman; D Kopelman
Journal:  Ann Oncol       Date:  2006-10-09       Impact factor: 32.976

9.  Comparison of the liver's respiratory motion in the supine and upright positions: concise communication.

Authors:  G Harauz; M J Bronskill
Journal:  J Nucl Med       Date:  1979-07       Impact factor: 10.057

10.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Authors:  Daniel A Low; Michelle Nystrom; Eugene Kalinin; Parag Parikh; James F Dempsey; Jeffrey D Bradley; Sasa Mutic; Sasha H Wahab; Tareque Islam; Gary Christensen; David G Politte; Bruce R Whiting
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

View more
  14 in total

1.  Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: a feasibility study.

Authors:  Jing Cai; Zheng Chang; Zhiheng Wang; William Paul Segars; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  High-quality t2-weighted 4-dimensional magnetic resonance imaging for radiation therapy applications.

Authors:  Dongsu Du; Shelton D Caruthers; Carri Glide-Hurst; Daniel A Low; H Harold Li; Sasa Mutic; Yanle Hu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-30       Impact factor: 7.038

3.  Reduction of acquisition time in the intersection profile method for four-dimensional magnetic resonance imaging reconstruction of thoracoabdominal organs.

Authors:  Windra Swastika; Yoshitada Masuda; Takashi Ohnishi; Hideaki Haneishi
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-03

Review 4.  MRI-guided focused ultrasound surgery.

Authors:  Ferenc A Jolesz
Journal:  Annu Rev Med       Date:  2009       Impact factor: 13.739

Review 5.  The role of texture analysis in imaging as an outcome predictor and potential tool in radiotherapy treatment planning.

Authors:  S Alobaidli; S McQuaid; C South; V Prakash; P Evans; A Nisbet
Journal:  Br J Radiol       Date:  2014-07-23       Impact factor: 3.039

6.  An MR-Based Model for Cardio-Respiratory Motion Compensation of Overlays in X-Ray Fluoroscopy.

Authors:  Peter Fischer; Anthony Faranesh; Thomas Pohl; Andreas Maier; Toby Rogers; Kanishka Ratnayaka; Robert Lederman; Joachim Hornegger
Journal:  IEEE Trans Med Imaging       Date:  2017-07-04       Impact factor: 10.048

7.  Respiratory amplitude guided 4-dimensional magnetic resonance imaging.

Authors:  Yanle Hu; Shelton D Caruthers; Daniel A Low; Parag J Parikh; Sasa Mutic
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-02-13       Impact factor: 7.038

8.  Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom.

Authors:  Yong Yue; Zhaoyang Fan; Wensha Yang; Jianing Pang; Zixin Deng; Elizabeth McKenzie; Richard Tuli; Robert Wallace; Debiao Li; Benedick Fraass
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

9.  An efficient model to guide prospective T2-weighted 4D magnetic resonance imaging acquisition.

Authors:  Dongsu Du; Sasa Mutic; H Harold Li; Yanle Hu
Journal:  Med Phys       Date:  2018-05-06       Impact factor: 4.071

10.  Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

Authors:  Yilin Liu; Fang-Fang Yin; DongJoo Rhee; Jing Cai
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

View more