Literature DB >> 15000619

4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Tinsu Pan1, Ting-Yim Lee, Eike Rietzel, George T Y Chen.   

Abstract

We propose a new scanning protocol for generating 4D-CT image data sets influenced by respiratory motion. A cine scanning protocol is used during data acquisition, and two registration methods are used to sort images into temporal phases. A volume is imaged in multiple acquisitions of 1 or 2 cm length along the cranial-caudal direction. In each acquisition, the scans are continuously acquired for a time interval greater than or equal to the average respiratory cycle plus the duration of the data for an image reconstruction. The x ray is turned off during CT table translation and the acquisition is repeated until the prescribed volume is completely scanned. The scanning for 20 cm coverage takes about 1 min with an eight-slice CT or 2 mins with a four-slice CT. After data acquisition, the CT data are registered into respiratory phases based on either an internal anatomical match or an external respiratory signal. The internal approach registers the data according to correlation of anatomy in the CT images between two adjacent locations in consecutive respiratory cycles. We have demonstrated the technique with ROIs placed in the region of diaphragm. The external approach registers the image data according to an externally recorded respiratory signal generated by the Real-Time Position Management (RPM) Respiratory Gating System (Varian Medical Systems, Palo Alto, CA). Compared with previously reported prospective or retrospective imaging of the respiratory motion with a single-slice or multi-slice CT, the 4D-CT method proposed here provides (1) a shorter scan time of three to six times faster than the single-slice CT with prospective gating; (2) a shorter scan time of two to four times improvement over a previously reported multi-slice CT implementation, and (3) images over all phases of a breathing cycle. We have applied the scanning and registration methods on phantom, animal and patients, and initial results suggest the applicability of both the scanning and the registration methods.

Entities:  

Mesh:

Year:  2004        PMID: 15000619     DOI: 10.1118/1.1639993

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  136 in total

1.  MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems.

Authors:  Nikolaos Dikaios; David Izquierdo-Garcia; Martin J Graves; Venkatesh Mani; Zahi A Fayad; Tim D Fryer
Journal:  Eur Radiol       Date:  2011-09-22       Impact factor: 5.315

2.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

3.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  Practical approaches to four-dimensional heavy-charged-particle lung therapy.

Authors:  Shinichiro Mori; Ziji Wu; Michael R Folkert; Motoki Kumagai; Suguru Dobashi; Toshio Sugane; Masayuki Baba
Journal:  Radiol Phys Technol       Date:  2009-10-14

5.  Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning.

Authors:  David A Zamora; Adam C Riegel; Xiaojun Sun; Peter Balter; George Starkschall; Osama Mawlawi; Tinsu Pan
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

6.  Patient-specific quantification of respiratory motion-induced dose uncertainty for step-and-shoot IMRT of lung cancer.

Authors:  Heng Li; Peter Park; Wei Liu; Jason Matney; Zhongxing Liao; Peter Balter; Yupeng Li; Xiaodong Zhang; Xiaoqiang Li; X Ronald Zhu
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

7.  A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer.

Authors:  J P Santoro; J McNamara; E Yorke; H Pham; A Rimner; K E Rosenzweig; G S Mageras
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

8.  Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate.

Authors:  Adam C Riegel; Moiz Ahmad; Xiaojun Sun; Tinsu Pan
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Determination of patient-specific internal gross tumor volumes for lung cancer using four-dimensional computed tomography.

Authors:  Muthuveni Ezhil; Sastry Vedam; Peter Balter; Bum Choi; Dragan Mirkovic; George Starkschall; Joe Y Chang
Journal:  Radiat Oncol       Date:  2009-01-27       Impact factor: 3.481

10.  MRI Investigation of the Linkage Between Respiratory Motion of the Heart and Markers on Patient's Abdomen and Chest: Implications for Respiratory Amplitude Binning List-Mode PET and SPECT Studies.

Authors:  Paul Dasari; Karen Johnson; Joyoni Dey; Clifford Lindsay; Mohammed S Shazeeb; Joyeeta Mitra Mukherjee; Shaokuan Zheng; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2014-02-06       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.