Literature DB >> 26158103

Reduction of acquisition time in the intersection profile method for four-dimensional magnetic resonance imaging reconstruction of thoracoabdominal organs.

Windra Swastika1, Yoshitada Masuda2, Takashi Ohnishi3, Hideaki Haneishi3.   

Abstract

We have previously proposed an intersection profile method for reconstructing four-dimensional (4-D) magnetic resonance imaging (MRI) consisting of one breathing cycle of the thoracoabdominal region. This method captures a set of temporal sequence images in a proper sagittal plane and sets of temporal sequence images in continuous coronal slices. The former set is used as a navigator slice and the latter sets are used as data slices. A 4-D MRI is reconstructed by synchronizing the respiratory pattern found in the navigator slice and the data slices. We propose a prospective method to reduce the acquisition time for data slices. During data slice acquisition, the synchronization process between the respiratory pattern found in the navigator slice and one data slice is monitored in real time. Data acquisition will be terminated and moved to the next data slice based on a threshold value. We used 14 data sets (seven patients with certain pulmonary disease and seven healthy volunteers) previously obtained for the original intersection profile method for a simulation using the proposed method to evaluate the time reduction and impact on image quality. Each of the data set was tested using three different threshold values and the acquisition time can be reduced up to 75%. Although the quantitative evaluation of image quality was slightly worse than that by the conventional method, the difference based on the visual inspection was subtle to human eyes.

Entities:  

Keywords:  four-dimensional magnetic resonance imaging; intersection profile method; respiratory motion; thoracoabdominal organs

Year:  2015        PMID: 26158103      PMCID: PMC4478969          DOI: 10.1117/1.JMI.2.2.024008

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  14 in total

1.  Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: a feasibility study.

Authors:  Jing Cai; Zheng Chang; Zhiheng Wang; William Paul Segars; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

Review 2.  4-dimensional computed tomography imaging and treatment planning.

Authors:  Paul Keall
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

3.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal.

Authors:  S S Vedam; P J Keall; V R Kini; H Mostafavi; H P Shukla; R Mohan
Journal:  Phys Med Biol       Date:  2003-01-07       Impact factor: 3.609

4.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

5.  Three-dimensional display in nuclear medicine.

Authors:  J W Wallis; T R Miller; C A Lerner; E C Kleerup
Journal:  IEEE Trans Med Imaging       Date:  1989       Impact factor: 10.048

6.  Four-dimensional magnetic resonance imaging for the determination of tumour movement and its evaluation using a dynamic porcine lung phantom.

Authors:  G Remmert; J Biederer; F Lohberger; M Fabel; G H Hartmann
Journal:  Phys Med Biol       Date:  2007-09-04       Impact factor: 3.609

7.  Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients.

Authors:  Wei Lu; Parag J Parikh; Issam M El Naqa; Michelle M Nystrom; James P Hubenschmidt; Sasha H Wahab; Sasa Mutic; Anurag K Singh; Gary E Christensen; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

8.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

9.  Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer.

Authors:  René W M Underberg; Frank J Lagerwaard; Johan P Cuijpers; Ben J Slotman; John R van Sörnsen de Koste; Suresh Senan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-11-15       Impact factor: 7.038

10.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Authors:  Daniel A Low; Michelle Nystrom; Eugene Kalinin; Parag Parikh; James F Dempsey; Jeffrey D Bradley; Sasa Mutic; Sasha H Wahab; Tareque Islam; Gary Christensen; David G Politte; Bruce R Whiting
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

View more