Literature DB >> 22149822

Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: a feasibility study.

Jing Cai1, Zheng Chang, Zhiheng Wang, William Paul Segars, Fang-Fang Yin.   

Abstract

PURPOSE: Four-dimensional computed tomography (4D-CT) has been widely used in radiation therapy to assess patient-specific breathing motion for determining individual safety margins. However, it has two major drawbacks: low soft-tissue contrast and an excessive imaging dose to the patient. This research aimed to develop a clinically feasible four-dimensional magnetic resonance imaging (4D-MRI) technique to overcome these limitations.
METHODS: The proposed 4D-MRI technique was achieved by continuously acquiring axial images throughout the breathing cycle using fast 2D cine-MR imaging, and then retrospectively sorting the images by respiratory phase. The key component of the technique was the use of body area (BA) of the axial MR images as an internal respiratory surrogate to extract the breathing signal. The validation of the BA surrogate was performed using 4D-CT images of 12 cancer patients by comparing the respiratory phases determined using the BA method to those determined clinically using the Real-time position management (RPM) system. The feasibility of the 4D-MRI technique was tested on a dynamic motion phantom, the 4D extended Cardiac Torso (XCAT) digital phantom, and two healthy human subjects.
RESULTS: Respiratory phases determined from the BA matched closely to those determined from the RPM: mean (± SD) difference in phase: -3.9% (± 6.4%); mean (± SD) absolute difference in phase: 10.40% (± 3.3%); mean (± SD) correlation coefficient: 0.93 (± 0.04). In the motion phantom study, 4D-MRI clearly showed the sinusoidal motion of the phantom; image artifacts observed were minimal to none. Motion trajectories measured from 4D-MRI and 2D cine-MRI (used as a reference) matched excellently: the mean (± SD) absolute difference in motion amplitude: -0.3 (± 0.5) mm. In the 4D-XCAT phantom study, the simulated "4D-MRI" images showed good consistency with the original 4D-XCAT phantom images. The motion trajectory of the hypothesized "tumor" matched excellently between the two, with a mean (± SD) absolute difference in motion amplitude of 0.5 (± 0.4) mm. 4D-MRI was able to reveal the respiratory motion of internal organs in both human subjects; superior-inferior (SI) maximum motion of the left kidney of Subject #1 and the diaphragm of Subject #2 measured from 4D-MRI was 0.88 and 1.32 cm, respectively.
CONCLUSIONS: Preliminary results of our study demonstrated the feasibility of a novel retrospective 4D-MRI technique that uses body area as a respiratory surrogate.

Entities:  

Mesh:

Year:  2011        PMID: 22149822      PMCID: PMC4108683          DOI: 10.1118/1.3658737

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

Review 1.  4-dimensional computed tomography imaging and treatment planning.

Authors:  Paul Keall
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

2.  Acquiring 4D thoracic CT scans using a multislice helical method.

Authors:  P J Keall; G Starkschall; H Shukla; K M Forster; V Ortiz; C W Stevens; S S Vedam; R George; T Guerrero; R Mohan
Journal:  Phys Med Biol       Date:  2004-05-21       Impact factor: 3.609

3.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI.

Authors:  Christian Plathow; Sebastian Ley; Christian Fink; Michael Puderbach; Waldemar Hosch; Astrid Schmähl; Jürgen Debus; Hans-Ulrich Kauczor
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-07-15       Impact factor: 7.038

4.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

Authors:  Martin J Murphy; James Balter; Stephen Balter; Jose A BenComo; Indra J Das; Steve B Jiang; C M Ma; Gustavo H Olivera; Raymond F Rodebaugh; Kenneth J Ruchala; Hiroki Shirato; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

Review 5.  Utility of the FIESTA pulse sequence in body oncologic imaging: review.

Authors:  Priya Bhosale; Jingfei Ma; Haesun Choi
Journal:  AJR Am J Roentgenol       Date:  2009-06       Impact factor: 3.959

6.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

7.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Authors:  Daniel A Low; Michelle Nystrom; Eugene Kalinin; Parag Parikh; James F Dempsey; Jeffrey D Bradley; Sasa Mutic; Sasha H Wahab; Tareque Islam; Gary Christensen; David G Politte; Bruce R Whiting
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

8.  4D-MRI analysis of lung tumor motion in patients with hemidiaphragmatic paralysis.

Authors:  Julien Dinkel; Christian Hintze; Ralf Tetzlaff; Peter E Huber; Klaus Herfarth; Juergen Debus; Hans U Kauczor; Christian Thieke
Journal:  Radiother Oncol       Date:  2009-04-24       Impact factor: 6.280

9.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

10.  Imaging tumour motion for radiotherapy planning using MRI.

Authors:  Hans-Ulrich Kauczor; Christian Plathow
Journal:  Cancer Imaging       Date:  2006-10-31       Impact factor: 3.909

View more
  83 in total

1.  High-quality t2-weighted 4-dimensional magnetic resonance imaging for radiation therapy applications.

Authors:  Dongsu Du; Shelton D Caruthers; Carri Glide-Hurst; Daniel A Low; H Harold Li; Sasa Mutic; Yanle Hu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-30       Impact factor: 7.038

2.  A mass-conserving 4D XCAT phantom for dose calculation and accumulation.

Authors:  Christopher L Williams; Pankaj Mishra; Joao Seco; Sara St James; Raymond H Mak; Ross I Berbeco; John H Lewis
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study.

Authors:  Wendy Harris; Fang-Fang Yin; Chunhao Wang; You Zhang; Jing Cai; Lei Ren
Journal:  Phys Med Biol       Date:  2017-12-14       Impact factor: 3.609

4.  Reduction of acquisition time in the intersection profile method for four-dimensional magnetic resonance imaging reconstruction of thoracoabdominal organs.

Authors:  Windra Swastika; Yoshitada Masuda; Takashi Ohnishi; Hideaki Haneishi
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-03

5.  A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT.

Authors:  Wendy Harris; Chunhao Wang; Fang-Fang Yin; Jing Cai; Lei Ren
Journal:  Med Phys       Date:  2018-06-13       Impact factor: 4.071

6.  Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy.

Authors:  Tatsuya J Arai; Joris Nofiele; Ananth J Madhuranthakam; Qing Yuan; Ivan Pedrosa; Rajiv Chopra; Amit Sawant
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

7.  Lung dynamic MRI deblurring using low-rank decomposition and dictionary learning.

Authors:  Shuiping Gou; Yueyue Wang; Jiaolong Wu; Percy Lee; Ke Sheng
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

8.  A tool for validating MRI-guided strategies: a digital breathing CT/MRI phantom of the abdominal site.

Authors:  Chiara Paganelli; Paul Summers; Chiara Gianoli; Massimo Bellomi; Guido Baroni; Marco Riboldi
Journal:  Med Biol Eng Comput       Date:  2017-04-08       Impact factor: 2.602

9.  A post-processing method based on interphase motion correction and averaging to improve image quality of 4D magnetic resonance imaging: a clinical feasibility study.

Authors:  Zixin Deng; Jianing Pang; Yi Lao; Xiaoming Bi; Guan Wang; Yuhua Chen; Matthias Fenchel; Richard Tuli; Debiao Li; Wensha Yang; Zhaoyang Fan
Journal:  Br J Radiol       Date:  2019-01-03       Impact factor: 3.039

10.  Retrospective 4D MR image construction from free-breathing slice Acquisitions: A novel graph-based approach.

Authors:  Yubing Tong; Jayaram K Udupa; Krzysztof C Ciesielski; Caiyun Wu; Joseph M McDonough; David A Mong; Robert M Campbell
Journal:  Med Image Anal       Date:  2016-08-13       Impact factor: 8.545

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.