Literature DB >> 12956265

A hybrid breast biopsy system combining ultrasound and MRI.

C A Piron1, P Causer, R Jong, R Shumak, D B Plewes.   

Abstract

System design and initial phantom accuracy results for a novel biopsy system integrating both magnetic resonance (MR) and ultrasound (US) imaging modalities are presented. A phantom experiment was performed to investigate the efficacy of this hybrid guidance biopsy technique in a breast tissue mimicking phantom. A comparison between MR-guided core biopsy verses MR/US-guided core biopsy of phantom targets was realized using a scoring system based on the consistency of the acquired core samples (14 gauge). It was determined that the addition of US to guide needle placement improved the accuracy from an average score of 7.4 out of 10 (MRI guidance alone), to 9.6 (MRI/US guidance) over 21 trials. The average amount of needle tip correction resulting from the additional US information was determined to be 3.7 mm. This correction value is substantial, equal to approximately one radius of the intended targets. Hybrid US/MRI guided biopsy appears to offer a simple means to ensure accurate breast tissue sampling without the need for repeat MRI scans for verification or the need for real-time imaging in open MRI geometries.

Entities:  

Mesh:

Year:  2003        PMID: 12956265     DOI: 10.1109/TMI.2003.816951

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

1.  Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation.

Authors:  Jin Zhang; Peter D Olcott; Garry Chinn; Angela M K Foudray; Craig S Levine
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

2.  Progress in multimodality imaging: truly simultaneous ultrasound and magnetic resonance imaging.

Authors:  Laura Curiel; Rajiv Chopra; Kullervo Hynynen
Journal:  IEEE Trans Med Imaging       Date:  2007-12       Impact factor: 10.048

3.  Adaptive 4D MR imaging using navigator-based respiratory signal for MRI-guided therapy.

Authors:  Junichi Tokuda; Shigehiro Morikawa; Hasnine A Haque; Tetsuji Tsukamoto; Kiyoshi Matsumiya; Hongen Liao; Ken Masamune; Takeyoshi Dohi
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

Review 4.  Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review.

Authors:  Rongrong Guo; Guolan Lu; Binjie Qin; Baowei Fei
Journal:  Ultrasound Med Biol       Date:  2017-10-26       Impact factor: 2.998

Review 5.  Breast image registration techniques: a survey.

Authors:  Yujun Guo; Radhika Sivaramakrishna; Cheng-Chang Lu; Jasjit S Suri; Swamy Laxminarayan
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

6.  Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors.

Authors:  Hao Peng; Craig S Levin
Journal:  Phys Med Biol       Date:  2010-04-19       Impact factor: 3.609

Review 7.  Efficacy of Second-Look Ultrasound with MR Coregistration for Evaluating Additional Enhancing Lesions of the Breast: Review of the Literature.

Authors:  Maria Antonietta Mazzei; Letizia Di Giacomo; Alfonso Fausto; Francesco Gentili; Francesco Giuseppe Mazzei; Luca Volterrani
Journal:  Biomed Res Int       Date:  2018-10-21       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.