Literature DB >> 18418605

Image quality on dual-source computed-tomographic coronary angiography.

Johannes Rixe1, Andreas Rolf, Guido Conradi, Albrecht Elsaesser, Helge Moellmann, Holger M Nef, Georg Bachmann, Christian W Hamm, Thorsten Dill.   

Abstract

Multi-detector CT reliably permits visualization of coronary arteries, but due to the occurrence of motion artefacts at heart rates >65 bpm caused by a temporal resolution of 165 ms, its utilisation has so far been limited to patients with a preferably low heart rate. We investigated the assessment of image quality on computed tomography of coronary arteries in a large series of patients without additional heart rate control using dual-source computed tomography (DSCT). DSCT (Siemens Somatom Definition, 83-ms temporal resolution) was performed in 165 consecutive patients (mean age 64 +/- 11.4 years) after injection of 60-80 ml of contrast. Data sets were reconstructed in 5% intervals of the cardiac cycle and evaluated by two readers in consensus concerning evaluability of the coronary arteries and presence of motion and beam-hardening artefacts using the AHA 16-segment coronary model. Mean heart rate during CT was 65 +/- 10.5 bpm; visualisation without artefacts was possible in 98.7% of 2,541 coronary segments. Only two segments were considered unevaluable due to cardiac motion; 30 segments were unassessable due to poor signal-to-noise ratio or coronary calcifications (both n = 15). Data reconstruction at 65-70% of the cardiac cycle provided for the best image quality. For heart rates >85 bpm, a systolic reconstruction at 45% revealed satisfactory results. Compared with earlier CT generations, DSCT provides for non-invasive coronary angiography with diagnostic image quality even at heart rates >65 bpm and thus may broaden the spectrum of patients that can be investigated non-invasively.

Entities:  

Mesh:

Year:  2008        PMID: 18418605     DOI: 10.1007/s00330-008-0947-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  31 in total

1.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

2.  Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Franz von Ziegler; Thorsten Johnson; Carsten Rist; Alexander Leber; Thomas Flohr; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Invest Radiol       Date:  2006-05       Impact factor: 6.016

3.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

Review 4.  Computed tomography coronary angiography.

Authors:  Stephan Achenbach
Journal:  J Am Coll Cardiol       Date:  2006-11-01       Impact factor: 24.094

5.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

6.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

7.  Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing.

Authors:  Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Andre Plass; Oliver Gaemperli; Ines Valenta; Lars Husmann; Thomas G Flohr; Michele Genoni; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-08       Impact factor: 6.016

8.  Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis.

Authors:  Piet K Vanhoenacker; Majanka H Heijenbrok-Kal; Ruben Van Heste; Isabel Decramer; Lieven R Van Hoe; William Wijns; M G Myriam Hunink
Journal:  Radiology       Date:  2007-08       Impact factor: 11.105

Review 9.  Diagnostic value of 64-slice CT angiography in coronary artery disease: a systematic review.

Authors:  Zhonghua Sun; Chenghsun Lin; Robert Davidson; Chiauhuei Dong; Yunchan Liao
Journal:  Eur J Radiol       Date:  2007-09-04       Impact factor: 3.528

10.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

View more
  12 in total

1.  Automatic selection of optimal systolic and diastolic reconstruction windows for dual-source CT coronary angiography.

Authors:  H Seifarth; M Puesken; S Wienbeck; D Maintz; R Fischbach; W Heindel; K-U Juergens
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

2.  Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients.

Authors:  Ming-Li Sun; Bin Lu; Run-Ze Wu; Laura Johnson; Lei Han; Gang Liu; Fang-Fang Yu; Zhi-Hui Hou; Yang Gao; Hong-Yu Wang; Shiliang Jiang; Yue-Jin Yang; Shu-Bin Qiao
Journal:  Eur Radiol       Date:  2011-04-12       Impact factor: 5.315

Review 3.  SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

Authors:  Sandra S Halliburton; Suhny Abbara; Marcus Y Chen; Ralph Gentry; Mahadevappa Mahesh; Gilbert L Raff; Leslee J Shaw; Jörg Hausleiter
Journal:  J Cardiovasc Comput Tomogr       Date:  2011 Jul-Aug

4.  Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction.

Authors:  Wei-Hua Yin; Bin Lu; Zhi-Hui Hou; Nan Li; Lei Han; Yong-Jian Wu; Hong-Xia Niu; Justin R Silverman; Carlo Nicola De Cecco; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2013-06-27       Impact factor: 5.315

5.  Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch.

Authors:  Matthias S May; Paul Deak; Axel Kuettner; Michael M Lell; Wolfgang Wuest; Michael Scharf; Andrea K Keller; Lothar Häberle; Stephan Achenbach; Martin Seltmann; Michael Uder; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-10-09       Impact factor: 5.315

6.  Image Quality of 256-Slice Computed Tomography for Coronary Angiography.

Authors:  Shu-Ping Chao; Jyh-Gang Leu; Wai-Yip Law; Chu-Jen Kuo; Kou-Gi Shyu
Journal:  Acta Cardiol Sin       Date:  2013-09       Impact factor: 2.672

7.  Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience.

Authors:  Sebastian Leschka; Paul Stolzmann; Lotus Desbiolles; Stephan Baumueller; Robert Goetti; Thomas Schertler; Hans Scheffel; Andre Plass; Volkmar Falk; Gudrun Feuchtner; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

8.  Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography.

Authors:  Harald Seifarth; Michael Puesken; John F Kalafut; Susanne Wienbeck; Johannes Wessling; David Maintz; Walter Heindel; Kai-Uwe Juergens
Journal:  Eur Radiol       Date:  2009-05-08       Impact factor: 5.315

9.  Optimal reconstruction interval in dual source CT coronary angiography: a single-center experience in 285 patients.

Authors:  Ayça Akgöz; Deniz Akata; Tuncay Hazırolan; Muşturay Karçaaltıncaba
Journal:  Diagn Interv Radiol       Date:  2014 Sep-Oct       Impact factor: 2.630

10.  Systolic acquisition of coronary dual-source computed tomography angiography: feasibility in an unselected patient population.

Authors:  Fabian Bamberg; Wieland H Sommer; Jan C Schenzle; Christoph R Becker; Konstantin Nikolaou; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Eur Radiol       Date:  2009-12-23       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.