Literature DB >> 17641365

Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis.

Piet K Vanhoenacker1, Majanka H Heijenbrok-Kal, Ruben Van Heste, Isabel Decramer, Lieven R Van Hoe, William Wijns, M G Myriam Hunink.   

Abstract

PURPOSE: To review the literature on the diagnostic performance of multidetector computed tomographic (CT) angiography for assessment of symptomatic coronary artery disease, with conventional coronary angiography as the reference standard.
MATERIALS AND METHODS: A PubMed and manual search of the literature published between January 1998 and May 2006 on use of multidetector CT angiography compared with coronary angiography in patients with symptomatic coronary artery disease was performed. Summary estimates of diagnostic odds ratio, sensitivity, and specificity were calculated. Random-effects models were used to compare the diagnostic performance of four-, 16-, and 64-detector CT angiographic units, and the proportion of nonassessable coronary arterial segments was evaluated.
RESULTS: Fifty-four studies were included in the meta-analysis: 22 studies with four-detector CT angiography, 26 with 16-detector CT angiography, and six with 64-detector CT angiography. The pooled sensitivity and specificity for detecting a greater than 50% stenosis per segment were 0.93 (95% confidence interval [CI]: 0.88, 0.97) and 0.96 (95% CI: 0.96, 0.97) for 64-detector CT angiography, 0.83 (95% CI: 0.76, 0.90) and 0.96 (95% CI: 0.95, 0.97) for 16-detector CT angiography, and 0.84 (95% CI: 0.81, 0.88) and 0.93 (95% CI: 0.91, 0.95) for four-detector CT angiography, respectively. Results of regression analysis indicated that the diagnostic performance significantly improved with the newer generations of multidetector CT scanners (64- and 16-detector vs four-detector units), adjusted for exclusion of nonassessable segments, and contrast agent concentration used (P < .05). Simultaneously, the nonassessable proportion of segments significantly decreased with the newer generations of multidetector CT scanners, adjusted for heart rate, prevalence of significant disease, and mean age.
CONCLUSION: With the newer generations of multidetector CT scanners, the diagnostic performance for the assessment of coronary artery disease has significantly improved, and the proportion of nonassessable segments has decreased.

Entities:  

Mesh:

Year:  2007        PMID: 17641365     DOI: 10.1148/radiol.2442061218

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  116 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography: design and implementation of the CORE320 multicenter, multinational diagnostic study.

Authors:  Andrea L Vavere; Gregory G Simon; Richard T George; Carlos E Rochitte; Andrew E Arai; Julie M Miller; Marcello Di Carli; Armin Arbab-Zadeh; Armin A Zadeh; Marc Dewey; Hiroyuki Niinuma; Roger Laham; Frank J Rybicki; Joanne D Schuijf; Narinder Paul; John Hoe; Sachio Kuribyashi; Hajime Sakuma; Cesar Nomura; Tan Swee Yaw; Klaus F Kofoed; Kunihiro Yoshioka; Melvin E Clouse; Jeffrey Brinker; Christopher Cox; Joao A C Lima
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-11-12

Review 3.  Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis.

Authors:  Zhonghua Sun; Kwan-Hoong Ng
Journal:  Int J Cardiovasc Imaging       Date:  2012-01-04       Impact factor: 2.357

4.  Coronary computed tomography angiography in coronary artery disease.

Authors:  Zhonghua Sun; Kwan-Hoong Ng
Journal:  World J Cardiol       Date:  2011-09-26

5.  Coronary flow reserve by CT perfusion.

Authors:  Richard T George; Frank M Bengel; Albert C Lardo
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

6.  Relationship between beat to beat coronary artery motion and image quality in prospectively ECG-gated two heart beat 320-detector row coronary CT angiography.

Authors:  Nobuo Tomizawa; Shuhei Komatsu; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-30       Impact factor: 2.357

7.  The potential role for the use of cardiac computed tomography angiography for the acute chest pain patient in the emergency department.

Authors:  Sean R Wilson; James K Min
Journal:  J Nucl Cardiol       Date:  2011-02       Impact factor: 5.952

8.  Multislice CT angiography in coronary artery disease: Technical developments, radiation dose and diagnostic value.

Authors:  Zhonghua Sun
Journal:  World J Cardiol       Date:  2010-10-26

Review 9.  Quantitative and qualitative analysis and interpretation of CT perfusion imaging.

Authors:  Carolina Valdiviezo; Marietta Ambrose; Vishal Mehra; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

Review 10.  Coronary CT angiography with prospective ECG-triggering: an effective alternative to invasive coronary angiography.

Authors:  Zhonghua Sun
Journal:  Cardiovasc Diagn Ther       Date:  2012-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.