Literature DB >> 19424699

Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography.

Harald Seifarth1, Michael Puesken, John F Kalafut, Susanne Wienbeck, Johannes Wessling, David Maintz, Walter Heindel, Kai-Uwe Juergens.   

Abstract

The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9 + or - 49.9)-396.1(+ or - 52.1) HU vs. 366.0(+ or - 64.3)-341.6(+ or - 72.5) HU; LAD: 398.9(+ or - 48.6)-364.6(+ or - 44.6) HU vs. 356.3(+ or - 69.5)-323.0(+ or - 67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(+ or - 52.1) vs. 370.7(+ or - 70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19424699     DOI: 10.1007/s00330-009-1421-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  44 in total

1.  Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection.

Authors:  K Hittmair; D Fleischmann
Journal:  J Comput Assist Tomogr       Date:  2001 Mar-Apr       Impact factor: 1.826

2.  Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2003-04-17       Impact factor: 11.105

3.  Optimal contrast application for cardiac 4-detector-row computed tomography.

Authors:  Christoph R Becker; Cheng Hong; Andreas Knez; Alexander Leber; Roland Bruening; U Joseph Schoepf; Maximilian F Reiser
Journal:  Invest Radiol       Date:  2003-11       Impact factor: 6.016

4.  Composition of coronary atherosclerotic plaques in patients with acute myocardial infarction and stable angina pectoris determined by contrast-enhanced multislice computed tomography.

Authors:  Alexander W Leber; Andreas Knez; Carl W White; Alexander Becker; Franz von Ziegler; Olaf Muehling; Christoph Becker; Maximilian Reiser; Gerhard Steinbeck; Peter Boekstegers
Journal:  Am J Cardiol       Date:  2003-03-15       Impact factor: 2.778

5.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

6.  Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in women versus men with angina pectoris.

Authors:  W Bob Meijboom; Annick C Weustink; Francesca Pugliese; Carlos A G van Mieghem; Nico R Mollet; Niels van Pelt; Filippo Cademartiri; Koen Nieman; Eleni Vourvouri; Eveline Regar; Gabriel P Krestin; Pim J de Feyter
Journal:  Am J Cardiol       Date:  2007-11-15       Impact factor: 2.778

7.  Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Stephanie Busch; Alexander W Leber; Alexander Becker; Bernd J Wintersperger; Carsten Rist; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Invest Radiol       Date:  2007-10       Impact factor: 6.016

8.  CT coronary angiography using 16 and 64 simultaneous detector rows: intraindividual comparison.

Authors:  M Dewey; H Hoffmann; B Hamm
Journal:  Rofo       Date:  2007-05-09

9.  Right heart: split-bolus injection of diluted contrast medium for visualization at coronary CT angiography.

Authors:  J Matthias Kerl; James G Ravenel; Shaun A Nguyen; Pal Suranyi; Christian Thilo; Philip Costello; Werner Bautz; U Joseph Schoepf
Journal:  Radiology       Date:  2008-03-27       Impact factor: 11.105

10.  Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight.

Authors:  Kazuo Awai; Kumiko Hiraishi; Shinichi Hori
Journal:  Radiology       Date:  2004-01       Impact factor: 11.105

View more
  13 in total

1.  Shorter delay time reduces interpatient variability in coronary enhancement in coronary CT angiography using the bolus tracking method with 320-row CT.

Authors:  Nobuo Tomizawa; Takeshi Nojo; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-22       Impact factor: 2.357

2.  Individually tailored contrast enhancement in CT pulmonary angiography.

Authors:  Babs M F Hendriks; Madeleine Kok; Casper Mihl; Sebastiaan C A M Bekkers; Joachim E Wildberger; Marco Das
Journal:  Br J Radiol       Date:  2016-01-22       Impact factor: 3.039

3.  Indications, imaging technique, and reading of cardiac computed tomography: survey of clinical practice.

Authors:  M H Maurer; E Zimmermann; P Schlattmann; C Germershausen; B Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2011-08-16       Impact factor: 5.315

4.  Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography.

Authors:  Fabian Stenzel; Matthias Rief; Elke Zimmermann; Johannes Greupner; Felicitas Richter; Marc Dewey
Journal:  Eur Radiol       Date:  2014-03-26       Impact factor: 5.315

5.  Minimizing individual variations in arterial enhancement on coronary CT angiographs using "contrast enhancement optimizer": a prospective randomized single-center study.

Authors:  Yoriaki Matsumoto; Toru Higaki; Takanori Masuda; Tomoyasu Sato; Yuko Nakamura; Fuminari Tatsugami; Kazuo Awai
Journal:  Eur Radiol       Date:  2018-11-12       Impact factor: 5.315

6.  High-pitch dual-source CT coronary angiography with low volumes of contrast medium.

Authors:  Alexander Lembcke; Carsten Schwenke; Patrick A Hein; Gesine Knobloch; Tahir Durmus; Bernd Hamm; Alexander Huppertz
Journal:  Eur Radiol       Date:  2013-08-15       Impact factor: 5.315

7.  Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Authors:  Sock Keow Tan; Kwan Hoong Ng; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Fadhli Mohamed Sani; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-04

8.  Investigation of the Utility and Safety of Dynamic Computed Tomography with Vasodilators.

Authors:  Jun Watanabe; Kanenori Endo; Yasutaka Tanaka; Keisuke Goto; Shoichi Urushibara; Tomohiro Osaki; Shigeru Tatebe; Seiichi Nakamura; Yasuaki Hirooka; Masahide Ikeguchi
Journal:  Yonago Acta Med       Date:  2020-01-24       Impact factor: 1.641

9.  Ultrafast imaging of the entire chest without ECG synchronisation or beta-blockade: to what extent can we analyse the coronary arteries?

Authors:  Maxime de Malherbe; Alain Duhamel; Nunzia Tacelli; Anne-Lise Hachulla; François Pontana; Jean-Baptiste Faivre; Jacques Remy; Martine Remy-Jardin
Journal:  Insights Imaging       Date:  2011-11-26

10.  Contrast Enhancement of the Right Ventricle during Coronary CT Angiography--Is It Necessary?

Authors:  Madeleine Kok; Bas L J H Kietselaer; Casper Mihl; Sibel Altintas; Estelle C Nijssen; Joachim E Wildberger; Marco Das
Journal:  PLoS One       Date:  2015-06-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.