Literature DB >> 18351346

Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study.

Sebastian T Schindera1, Rendon C Nelson, Laurens Howle, Eli Nichols, David M DeLong, Elmar M Merkle.   

Abstract

The effect of varying injection rates of a saline chaser on aortic enhancement in computed tomography (CT) angiography was determined. Single-level, dynamic CT images of a physiological flow phantom were acquired between 0 and 50 s after initiation of contrast medium injection. Four injection protocols were applied with identical contrast medium administration (150 ml injected at 5 ml/s). For baseline protocol A, no saline chaser was applied. For protocols B, C, and D, 50 ml of saline was injected at 2.5 ml/s, 5 ml/s, and 10 ml/s, respectively. Injecting the saline chaser at twice the rate as the contrast medium yielded significantly higher peak aortic enhancement values than injecting the saline at half or at the same rate as the contrast medium (P < 0.05). Average peak aortic enhancement (HU) measured 214, 214, 218, and 226 for protocols A, B, C, and D, respectively. The slower the saline-chaser injection rate, the longer the duration of 90% peak enhancement: 13.6, 12.2, and 11.7 s for protocols B, C, and D, respectively (P > 0.05). In CT angiography, saline chaser injected at twice the rate as the contrast medium leads to increased peak aortic enhancement and saline chaser injected at half the rate tends towards prolonging peak aortic enhancement plateau.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18351346     DOI: 10.1007/s00330-008-0911-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  14 in total

1.  Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: pharmacokinetic analysis and experimental porcine model.

Authors:  K T Bae; H Q Tran; J P Heiken
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

2.  Aortoiliac enhancement during computed tomography angiography with reduced contrast material dose and saline solution flush: influence on magnitude and uniformity of the contrast column.

Authors:  Helmut Schoellnast; Manfred Tillich; Michael J Deutschmann; Hannes A Deutschmann; Gottfried J Schaffler; Horst R Portugaller
Journal:  Invest Radiol       Date:  2004-01       Impact factor: 6.016

3.  Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector.

Authors:  K D Hopper; T J Mosher; C J Kasales; T R TenHave; D A Tully; J S Weaver
Journal:  Radiology       Date:  1997-10       Impact factor: 11.105

4.  Contrast-enhanced CT with saline flush technique using two automated injectors: how much contrast medium does it save?

Authors:  Toshiyuki Irie; Motonao Kajitani; Masayuki Yamaguchi; Yuji Itai
Journal:  J Comput Assist Tomogr       Date:  2002 Mar-Apr       Impact factor: 1.826

5.  Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model.

Authors:  K T Bae; J P Heiken; J A Brink
Journal:  Radiology       Date:  1998-06       Impact factor: 11.105

6.  Sixteen-detector row CT angiography of carotid arteries: comparison of different volumes of contrast material with and without a bolus chaser.

Authors:  Cécile de Monyé; Filippo Cademartiri; Thomas T de Weert; Dorine A M Siepman; Diederik W J Dippel; Aad van Der Lugt
Journal:  Radiology       Date:  2005-09-16       Impact factor: 11.105

7.  Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT.

Authors:  Florence Orlandini; Stéphanie Boini; Sandrine Iochum-Duchamps; Toufik Batch; Xavier Zhu; Alain Blum
Journal:  AJR Am J Roentgenol       Date:  2006-08       Impact factor: 3.959

8.  Using a saline chaser to decrease contrast media in abdominal CT.

Authors:  Paul J Dorio; Fred T Lee; Kevin P Henseler; Mark Pilot; Myron A Pozniak; Thomas C Winter; Sarah A Shock
Journal:  AJR Am J Roentgenol       Date:  2003-04       Impact factor: 3.959

9.  CTA contrast enhancement of the aorta and pulmonary artery: the effect of saline chase injected at two different rates in a canine experimental model.

Authors:  Chang Hyun Lee; Jin Mo Goo; Kyongtae T Bae; Hyun Ju Lee; Kwang Gi Kim; Eun Ju Chun; Chang Min Park; Jung-Gi Im
Journal:  Invest Radiol       Date:  2007-07       Impact factor: 6.016

10.  Abdominal multidetector row computed tomography: reduction of cost and contrast material dose using saline flush.

Authors:  Helmut Schoellnast; Manfred Tillich; Hannes A Deutschmann; Michael J Deutschmann; Gerald A Fritz; Uwe Stessel; Gottfried J Schaffler; Martin M Uggowitzer
Journal:  J Comput Assist Tomogr       Date:  2003 Nov-Dec       Impact factor: 1.826

View more
  5 in total

Review 1.  Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

Authors:  Charbel Saade; Ibrahim Alsheikh Deeb; Maha Mohamad; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  Diagn Interv Radiol       Date:  2016 Mar-Apr       Impact factor: 2.630

2.  Effect of varying contrast material iodine concentration and injection technique on the conspicuity of hepatocellular carcinoma during 64-section MDCT of patients with cirrhosis.

Authors:  A Guerrisi; D Marin; R C Nelson; G De Filippis; M Di Martino; H Barnhart; R Masciangelo; I Guerrisi; R Passariello; C Catalano
Journal:  Br J Radiol       Date:  2011-08       Impact factor: 3.039

3.  Novel connecting tube for saline chaser in contrast-enhanced CT: the effect of spiral flow of saline on contrast enhancement.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Kazuo Awai; Koji Yuba; Takayuki Kobayashi; Young-Kwang Park; Takanobu Yagi; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-06-12       Impact factor: 5.315

4.  The Effect of Contrast Material on Radiation Dose at CT: Part I. Incorporation of Contrast Material Dynamics in Anthropomorphic Phantoms.

Authors:  Pooyan Sahbaee; W Paul Segars; Daniele Marin; Rendon C Nelson; Ehsan Samei
Journal:  Radiology       Date:  2017-01-13       Impact factor: 11.105

5.  64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement.

Authors:  Daniele Marin; Rendon C Nelson; Antonino Guerrisi; Huiman Barnhart; Sebastian T Schindera; Roberto Passariello; Carlo Catalano
Journal:  Eur Radiol       Date:  2011-05-11       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.