OBJECTIVE: To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography.
MATERIALS AND METHODS: This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol A), contrast injection with saline chase injected at the same rate as the contrast medium (protocol B), and contrast injection with saline chase injected at half the rate (0.4 mL/s) of the contrast medium (protocol C). In the 3 dogs used in our study, each of the protocols was applied twice for every dog resulting in a total of 18 sessions of monitoring scans. CT images were acquired every second at the fixed level of the aorta and pulmonary artery (PA). The duration of plateau, plateau deviation, and peak arterial enhancement were computed and compared using the Kruskall-Wallis and Mann-Whitney U test.
RESULTS: Peak contrast enhancements were significantly more delayed with protocol B than with protocol A in both the PA (B: 48 seconds, A: 30 seconds, P=0.024) and aorta (B: 46 seconds, A: 38 seconds, P=0.024). The duration of enhancement plateau was longer with protocol B than with protocol A in PA (B: 14.8 seconds, A: 9.0 seconds, P=0.002) and in aorta (B: 16.2 seconds, A: 11.6 seconds, P=0.004). Protocol C had the longest duration of plateau in both PA (34.5 seconds, P=0.002) and aorta (33.8 seconds, P=0.004) with uniform plateau enhancement. The peak enhancement values of protocol C, however, were substantially lower than that of protocol A and B in both the PA (A: 262 HU, B: 239 HU, C: 191 HU, P=0.001) and aorta (A: 263 HU, B: 268 HU, C: 210 HU, P=0.001).
CONCLUSIONS: Saline chase prolongs the duration of plateau and delays peak enhancement of the pulmonary artery and aorta. Saline chase injected at half the rate of contrast medium injection allowed more uniform and prolonged plateau contrast enhancement than other protocols.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17568270     DOI: 10.1097/RLI.0b013e318032a9fe

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  7 in total

1.  Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study.

Authors:  Sebastian T Schindera; Rendon C Nelson; Laurens Howle; Eli Nichols; David M DeLong; Elmar M Merkle
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 5.315

2.  Novel connecting tube for saline chaser in contrast-enhanced CT: the effect of spiral flow of saline on contrast enhancement.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Kazuo Awai; Koji Yuba; Takayuki Kobayashi; Young-Kwang Park; Takanobu Yagi; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-06-12       Impact factor: 5.315

3.  Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography.

Authors:  Takeshi Nakaura; Kazuo Awai; Yumi Yanaga; Tomohiro Namimoto; Daisuke Utsunomiya; Toshinori Hirai; Seigo Sugiyama; Hisao Ogawa; Masahito Aoyama; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2011-09-01       Impact factor: 2.374

4.  64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement.

Authors:  Daniele Marin; Rendon C Nelson; Antonino Guerrisi; Huiman Barnhart; Sebastian T Schindera; Roberto Passariello; Carlo Catalano
Journal:  Eur Radiol       Date:  2011-05-11       Impact factor: 5.315

5.  Pulmonary angiography with 64-multidetector-row computed tomography in normal dogs.

Authors:  Randi Drees; Alex Frydrychowicz; Nicholas S Keuler; Scott B Reeder; Rebecca Johnson
Journal:  Vet Radiol Ultrasound       Date:  2011-05-04       Impact factor: 1.363

Review 6.  Chest computed tomography angiography in children on extracorporeal membrane oxygenation (ECMO).

Authors:  Nathan C Hull; Gary R Schooler; Larry A Binkovitz; Eric E Williamson; Phillip A Araoz; Lifeng Yu; Philip M Young
Journal:  Pediatr Radiol       Date:  2017-12-07

7.  An optimised patient-specific approach to administration of contrast agent for CT pulmonary angiography.

Authors:  Charbel Saade; Roger Bourne; Fadi El-Merhi; Arjuna Somanathan; Dev Chakraborty; Patrick Brennan
Journal:  Eur Radiol       Date:  2013-06-04       Impact factor: 5.315

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.