Literature DB >> 11884789

Contrast-enhanced CT with saline flush technique using two automated injectors: how much contrast medium does it save?

Toshiyuki Irie1, Motonao Kajitani, Masayuki Yamaguchi, Yuji Itai.   

Abstract

PURPOSE: The purpose of this work was to investigate the volume of contrast medium saved by the saline flush technique.
METHOD: Thoracic helical CT was performed by injecting 75 ml of contrast material (Ioversol 320) only (n = 25; Group A) or 75 ml of contrast medium pushed with 6 ml (n = 25; Group B), 12 ml (n = 25; Group C), 25 ml (n = 25; Group D), or 50 ml (n = 25; Group E) of saline at a rate of 2 ml/s. The aortic CT numbers were measured from 30 to 55 s after the beginning of injection. We compared the time to peak aortic enhancement (TPAE) among Groups A-E.
RESULTS: The TPAEs of the Groups A-E were 42.6, 45.2, 48.6, 48.4, and 48.3 s, respectively, and there was a statistically significant difference among them (p < 0.0001, analysis of variance). Post hoc test revealed statistically significant differences in TPAE between Groups A and B, C, D, and E and between Groups B and C, D, and E but no differences among Groups C, D, and E.
CONCLUSION: The saline flush technique prolongs TPAE by 6 s and saves 12 ml of contrast medium.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11884789     DOI: 10.1097/00004728-200203000-00022

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  7 in total

1.  Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser.

Authors:  Dae Young Yoon; Su Yeon You; Chul Soon Choi; Suk Ki Chang; Eun Joo Yun; Young Lan Seo; Sang Joon Park; Yu-Jin Lee; Jeung Hee Moon; Young-Soo Rho; Jin-Hwan Kim
Journal:  Neuroradiology       Date:  2006-09-15       Impact factor: 2.804

2.  Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study.

Authors:  Sebastian T Schindera; Rendon C Nelson; Laurens Howle; Eli Nichols; David M DeLong; Elmar M Merkle
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 5.315

3.  Operation of bolus tracking system for prediction of aortic peak enhancement at multidetector row computed tomography: pharmacokinetic analysis and clinical study.

Authors:  Isao Yamaguchi; Hiroyuki Hayashi; Masayuki Suzuki; Katsuhiro Ichikawa; Eiji Kidoya; Hirohiko Kimura
Journal:  Radiat Med       Date:  2008-07-27

4.  Novel connecting tube for saline chaser in contrast-enhanced CT: the effect of spiral flow of saline on contrast enhancement.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Kazuo Awai; Koji Yuba; Takayuki Kobayashi; Young-Kwang Park; Takanobu Yagi; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-06-12       Impact factor: 5.315

5.  The Effect of Contrast Material on Radiation Dose at CT: Part I. Incorporation of Contrast Material Dynamics in Anthropomorphic Phantoms.

Authors:  Pooyan Sahbaee; W Paul Segars; Daniele Marin; Rendon C Nelson; Ehsan Samei
Journal:  Radiology       Date:  2017-01-13       Impact factor: 11.105

6.  64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement.

Authors:  Daniele Marin; Rendon C Nelson; Antonino Guerrisi; Huiman Barnhart; Sebastian T Schindera; Roberto Passariello; Carlo Catalano
Journal:  Eur Radiol       Date:  2011-05-11       Impact factor: 5.315

7.  A practical biphasic contrast media injection protocol strongly enhances the aorta and pulmonary artery simultaneously using a single CT angiography scan.

Authors:  Cheng-Chih Hsieh; An-Bang Zeng; Chia-Hung Chen; Zong-Yi Jhou; Chih-Hsin Wang; Ya-Ling Yang; Feng-Chuan Hsieh; Jing-Kai Lin; Ju-Yen Yeh; Chun-Chao Huang
Journal:  BMC Med Imaging       Date:  2021-10-30       Impact factor: 1.930

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.