Literature DB >> 16170011

Sixteen-detector row CT angiography of carotid arteries: comparison of different volumes of contrast material with and without a bolus chaser.

Cécile de Monyé1, Filippo Cademartiri, Thomas T de Weert, Dorine A M Siepman, Diederik W J Dippel, Aad van Der Lugt.   

Abstract

PURPOSE: To prospectively compare different volumes of intravenously administered contrast material with and without a bolus chaser at 16-detector row computed tomographic (CT) angiography of the carotid arteries.
MATERIALS AND METHODS: Institutional Review Board approval and informed consent were obtained. Seventy-five consecutive patients (44 men, 31 women; mean age, 63 years; range, 22-85 years) were allocated to one of three protocols: group 1, 80 mL of contrast material; group 2, 80 mL of contrast material followed by 40 mL of saline; and group 3, 60 mL of contrast material followed by 40 mL of saline. Bolus tracking was used to synchronize contrast material injection with CT scanning. The attenuation in Hounsfield units was measured from the ascending aorta to the intracranial arteries at 1-second intervals. Differences were tested with the Student t test.
RESULTS: The maximum attenuation was reached in the proximal internal carotid artery in all groups. The addition of a bolus chaser to 80-mL contrast material resulted in a higher mean attenuation (323 HU +/- 39 vs 351 HU +/- 60, P = .06), higher maximum attenuation (393 HU +/- 53 vs 425 HU +/- 76, P = .09), and higher minimum attenuation (240 HU +/- 34 vs 264 HU +/- 48, P < .05). Group 3 had lower mean, maximum, and minimum attenuation than did groups 1 and 2 (P < .001).
CONCLUSION: The addition of a bolus chaser to 80 mL of contrast material results in a slightly higher attenuation. Decreasing the volume of contrast material from 80 to 60 mL results in a significantly lower attenuation.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16170011     DOI: 10.1148/radiol.2372040653

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  23 in total

1.  Comparison of different volumes of saline flush in the assessment of perivenous artefacts in the subclavian vein during cervical CT angiography.

Authors:  N Takeyama; Y Ohgiya; T Hayashi; T Takahashi; D Takasu; J Nakashima; K Kato; Y Kinebuchi; T Hashimoto; T Gokan
Journal:  Br J Radiol       Date:  2010-11-02       Impact factor: 3.039

2.  Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser.

Authors:  Dae Young Yoon; Su Yeon You; Chul Soon Choi; Suk Ki Chang; Eun Joo Yun; Young Lan Seo; Sang Joon Park; Yu-Jin Lee; Jeung Hee Moon; Young-Soo Rho; Jin-Hwan Kim
Journal:  Neuroradiology       Date:  2006-09-15       Impact factor: 2.804

3.  The emerging role of multidetector row CT angiography in the diagnosis of cervical arterial dissection: preliminary study.

Authors:  Lucas Elijovich; Khuram Kazmi; Jean Yves Gauvrit; Meng Law
Journal:  Neuroradiology       Date:  2006-06-03       Impact factor: 2.804

4.  Evaluation of an improved technique for lumen path definition and lumen segmentation of atherosclerotic vessels in CT angiography.

Authors:  Evert F S van Velsen; Wiro J Niessen; Thomas T de Weert; Cécile de Monyé; Aad van der Lugt; Erik Meijering; Rik Stokking
Journal:  Eur Radiol       Date:  2006-11-01       Impact factor: 5.315

5.  Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study.

Authors:  Sebastian T Schindera; Rendon C Nelson; Laurens Howle; Eli Nichols; David M DeLong; Elmar M Merkle
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 5.315

6.  Is a fetal origin of the posterior cerebral artery a risk factor for TIA or ischemic stroke? A study with 16-multidetector-row CT angiography.

Authors:  Cécile de Monyé; Diederik W J Dippel; Theodora A M Siepman; Marcel L Dijkshoorn; Hervé L J Tanghe; Aad van der Lugt
Journal:  J Neurol       Date:  2008-02-18       Impact factor: 4.849

7.  Novel connecting tube for saline chaser in contrast-enhanced CT: the effect of spiral flow of saline on contrast enhancement.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Kazuo Awai; Koji Yuba; Takayuki Kobayashi; Young-Kwang Park; Takanobu Yagi; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-06-12       Impact factor: 5.315

8.  Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner-Facing the Facts.

Authors:  M Wehrschuetz; E Wehrschuetz; H Schuchlenz; G Schaffler
Journal:  Clin Med Insights Cardiol       Date:  2010-03-08

9.  Quality of extracranial carotid evaluation with 256-section CT.

Authors:  J M Johnson; M S Reed; H N Burbank; C G Filippi
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-07       Impact factor: 3.825

10.  Atherosclerotic plaque volume and composition in symptomatic carotid arteries assessed with multidetector CT angiography; relationship with severity of stenosis and cardiovascular risk factors.

Authors:  S Rozie; T T de Weert; C de Monyé; P J Homburg; H L J Tanghe; D W J Dippel; A van der Lugt
Journal:  Eur Radiol       Date:  2009-04-22       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.