Literature DB >> 14600448

Abdominal multidetector row computed tomography: reduction of cost and contrast material dose using saline flush.

Helmut Schoellnast1, Manfred Tillich, Hannes A Deutschmann, Michael J Deutschmann, Gerald A Fritz, Uwe Stessel, Gottfried J Schaffler, Martin M Uggowitzer.   

Abstract

OBJECTIVE: To evaluate the potential of a saline solution flush after the contrast material bolus in abdominal multidetector row CT (MDCT) in contrast material dose and cost reduction.
METHODS: Abdominal MDCT was performed in 78 patients who were assigned randomly to 2 groups receiving 120 mL nonionic contrast material (300 mgI/mL) alone or 100 mL of the same contrast material pushed with 40 mL of saline solution. Mean attenuation values for both groups were measured in the liver, the spleen, the pancreas, the portal vein, the inferior vena cava, and the abdominal aorta. Cost analyses were performed for both groups.
RESULTS: There was no significant difference in parenchymal and vascular enhancement between both groups. The difference of the enhancement was 2 HU for the liver (P = 0.11), 2 HU for the spleen (P = 0.44), 3 HU for the pancreas (P = 0.38), 9 HU for the portal vein (P = 0.11), 3 HU for the inferior vena cava (P = 0.55), and 10 HU for the aorta (P = 0.06). Taking the costs of contrast material, saline solution, and disposal material into account, 7.30 dollars was saved by the patient using a saline solution flush.
CONCLUSIONS: Using a saline flush after the contrast material bolus in abdominal MDCT allows an iodine dose reduction of approximately 6 g, or 17%, without impairing mean parenchymal and vascular enhancement and a cost reduction of 7.30 dollars per patient.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14600448     DOI: 10.1097/00004728-200311000-00002

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  3 in total

1.  [Multidetector computed tomography of the liver].

Authors:  W Schima; C Kulinna; A Ba-Ssalamah; T Grünberger
Journal:  Radiologe       Date:  2005-01       Impact factor: 0.635

2.  Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study.

Authors:  Sebastian T Schindera; Rendon C Nelson; Laurens Howle; Eli Nichols; David M DeLong; Elmar M Merkle
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 5.315

3.  64-section multidetector CT of the upper abdomen: optimization of a saline chaser injection protocol for improved vascular and parenchymal contrast enhancement.

Authors:  Daniele Marin; Rendon C Nelson; Antonino Guerrisi; Huiman Barnhart; Sebastian T Schindera; Roberto Passariello; Carlo Catalano
Journal:  Eur Radiol       Date:  2011-05-11       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.