Literature DB >> 14701985

Aortoiliac enhancement during computed tomography angiography with reduced contrast material dose and saline solution flush: influence on magnitude and uniformity of the contrast column.

Helmut Schoellnast1, Manfred Tillich, Michael J Deutschmann, Hannes A Deutschmann, Gottfried J Schaffler, Horst R Portugaller.   

Abstract

RATIONALE AND
OBJECTIVES: To compare the magnitude and uniformity of aortoiliac contrast enhancement obtained from uniphasic contrast material injections versus contrast material injections with reduced iodine dose followed by a saline flush in aortoiliac multislice CT angiography (CTA).
METHODS: Twenty-nine patients with abdominal aortic aneurysms underwent aortoiliac CTA using protocols A and B. With protocol A, 120 mL contrast material (300 mgI/mL), and with protocol B, 100 mL contrast material followed by a 40-mL saline solution flush were administered at a flow rate of 4 mL/s. Quantitative analysis was performed by calculating mean aortoiliac attenuation, mean plateau deviation, and mean difference between maximum and minimum attenuation value for both groups. Qualitative analysis was performed by visual assessment of vascular enhancement using 2-dimensional and 3-dimensional postprocessing techniques.
RESULTS: The mean aortoiliac attenuation with protocol A was 291 +/- 62 HU, and with protocol B it was 285 +/- 61 HU. The difference of 6 HU was not statistically significant (P = 0.27). Mean plateau deviation was significantly smaller using protocol A than protocol B (16 +/- 9 HU vs. 20 +/- 10 HU, P = 0.03). In addition, the mean difference between maximum and minimum attenuation value was significantly smaller with protocol A than with protocol B (59 +/- 29 HU vs. 72 +/- 32 HU, P = 0.01). Visual analysis showed no difference in contrast material magnitude and homogeneity between the protocols.
CONCLUSIONS: In aortoiliac CTA, a saline solution flush after contrast material bolus allows an iodine dose reduction of approximately 20 mL without impairing the magnitude of contrast enhancement but degrades the uniformity of the contrast column. However, the degradation does not affect visual analysis.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14701985     DOI: 10.1097/01.rli.0000091841.45342.84

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  6 in total

1.  Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study.

Authors:  Selma Uysal Ramadan; Pinar Kosar; Iclal Sonmez; Sevilay Karahan; Ugur Kosar
Journal:  Eur Radiol       Date:  2010-05-01       Impact factor: 5.315

2.  Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser.

Authors:  Dae Young Yoon; Su Yeon You; Chul Soon Choi; Suk Ki Chang; Eun Joo Yun; Young Lan Seo; Sang Joon Park; Yu-Jin Lee; Jeung Hee Moon; Young-Soo Rho; Jin-Hwan Kim
Journal:  Neuroradiology       Date:  2006-09-15       Impact factor: 2.804

3.  Effect of varying injection rates of a saline chaser on aortic enhancement in CT angiography: phantom study.

Authors:  Sebastian T Schindera; Rendon C Nelson; Laurens Howle; Eli Nichols; David M DeLong; Elmar M Merkle
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 5.315

4.  Novel connecting tube for saline chaser in contrast-enhanced CT: the effect of spiral flow of saline on contrast enhancement.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Kazuo Awai; Koji Yuba; Takayuki Kobayashi; Young-Kwang Park; Takanobu Yagi; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-06-12       Impact factor: 5.315

5.  Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose.

Authors:  Chien-Ming Chen; Sung-Yu Chu; Ming-Yi Hsu; Ying-Lan Liao; Hui-Yu Tsai
Journal:  Eur Radiol       Date:  2013-10-02       Impact factor: 5.315

Review 6.  Multimodal CT in Acute Stroke.

Authors:  R Wannamaker; B Buck; K Butcher
Journal:  Curr Neurol Neurosci Rep       Date:  2019-07-27       Impact factor: 5.081

  6 in total