Literature DB >> 18196411

Alumina-on-alumina in THA: a multicenter prospective study.

Eduardo Garcia-Cimbrelo1, Eduardo Garcia-Rey, Antonio Murcia-Mazón, Agustín Blanco-Pozo, Eduardo Martí.   

Abstract

UNLABELLED: Different bearing surfaces, including alumina-on-alumina, have been used to avoid osteolysis. We prospectively followed 288 patients (319 hips) in which an alumina-on-alumina cup was used with a hydroxyapatite stem. The patients' mean age was 52.7 (range, 14-70 years), and the minimum followup was 3 years (mean, 4.7 years; range, 3-8 years). At final followup, five cups (including one with an alumina liner fracture) and two stems underwent revision. The cumulative probability of not having a revision of one or both components for any cause was 97% (95% confidence interval, 94.7%-99.1%). No patient spontaneously reported any noises from the hip and none reported noises when specifically questioned. All patients who had not undergone revision had good clinical results, but five of these patients had radiographic cup loosening at last followup. These data suggest alumina-on-alumina prostheses had reasonable outcomes after 5 years. One acetabular component fractured from trauma. We observed no linear femoral head penetration. Continued followup will be required to determine if reduction in wear between the alumina-on-alumina bearings results in less osteolysis and loosening. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18196411      PMCID: PMC2505151          DOI: 10.1007/s11999-007-0042-1

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  34 in total

1.  The case for porous-coated hip implants. The femoral side.

Authors:  C A Engh; A H Glassman; K E Suthers
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

2.  Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results.

Authors:  R C Johnston; R H Fitzgerald; W H Harris; R Poss; M E Müller; C B Sledge
Journal:  J Bone Joint Surg Am       Date:  1990-02       Impact factor: 5.284

3.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

4.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

5.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

6.  Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study.

Authors:  Moussa Hamadouche; Pierre Boutin; Jacques Daussange; Mark E Bolander; Laurent Sedel
Journal:  J Bone Joint Surg Am       Date:  2002-01       Impact factor: 5.284

7.  Alumina-on-alumina hip replacement. Results and survivorship in young patients.

Authors:  L Sedel; L Kerboull; P Christel; A Meunier; J Witvoet
Journal:  J Bone Joint Surg Br       Date:  1990-07

8.  Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years. A six- to 11-year evaluation.

Authors:  P Bizot; D Hannouche; R Nizard; J Witvoet; L Sedel
Journal:  J Bone Joint Surg Br       Date:  2004-03

9.  New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty.

Authors:  James D'Antonio; William Capello; Michael Manley; Benjamin Bierbaum
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

10.  Fractures of ceramic bearings: history and present status.

Authors:  Didier Hannouche; Christophe Nich; Pascal Bizot; Alain Meunier; Rémi Nizard; Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2003-12       Impact factor: 4.176

View more
  13 in total

1.  Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up.

Authors:  Alexander M Kress; Rainer Schmidt; Ulrich Holzwarth; Raimund Forst; Lutz A Mueller
Journal:  Int Orthop       Date:  2010-11-16       Impact factor: 3.075

2.  Alumina-on-alumina THA in patients with juvenile idiopathic arthritis: a 5-year followup study.

Authors:  Ana Cruz-Pardos; Eduardo García-Rey; Eduardo García-Cimbrelo; Jose Ortega-Chamarro
Journal:  Clin Orthop Relat Res       Date:  2011-08-31       Impact factor: 4.176

3.  Squeaking and microcracks in a delta-delta ceramic coupling: pin-on-disc study.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tadami Matsumoto; Kazuhiro Shintani
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-12

4.  Meta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients.

Authors:  Tae-Hun Lee; Young-Wan Moon; Seung-Jae Lim; Youn-Soo Park
Journal:  Hip Pelvis       Date:  2014-06-30

Review 5.  The incidence of implant fractures after total hip arthroplasty.

Authors:  Patrick Sadoghi; Wolfram Pawelka; Michael C Liebensteiner; Alexandra Williams; Andreas Leithner; Gerold Labek
Journal:  Int Orthop       Date:  2014-01       Impact factor: 3.075

6.  Third and fourth generation ceramic-on-ceramic total hip arthroplasty at a minimum of ten years.

Authors:  Cathal J McCarthy; John Mahon; Gerard A Sheridan; Adanna Welch-Phillips; John M O'Byrne; Paddy J Kenny
Journal:  J Clin Orthop Trauma       Date:  2022-07-06

7.  Alumina-on-alumina total hip arthroplasty in young patients: diagnosis is more important than age.

Authors:  Eduardo Garcia-Rey; Ana Cruz-Pardos; Eduardo Garcia-Cimbrelo
Journal:  Clin Orthop Relat Res       Date:  2009-06-04       Impact factor: 4.176

8.  Ceramic head fracture in ceramic-on-polyethylene total hip arthroplasty.

Authors:  Jae-Hwi Nho; Jong-Seok Park; Ui-Seoub Song; Woo-Jong Kim; You-Sung Suh
Journal:  Yonsei Med J       Date:  2013-11       Impact factor: 2.759

9.  Ceramic-on-ceramic THA Implants in Patients Younger Than 20 Years.

Authors:  Didier Hannouche; Flore Devriese; Jérôme Delambre; Frédéric Zadegan; Idriss Tourabaly; Laurent Sedel; Sylvie Chevret; Rémy Nizard
Journal:  Clin Orthop Relat Res       Date:  2015-09-04       Impact factor: 4.176

10.  Long-term results of 32-mm alumina-on-alumina THA for avascular necrosis of the femoral head.

Authors:  Giuseppe Solarino; Andrea Piazzolla; Angela Notarnicola; Lorenzo Moretti; Silvio Tafuri; Silvana De Giorgi; Biagio Moretti
Journal:  J Orthop Traumatol       Date:  2012-01-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.