Literature DB >> 35865324

Third and fourth generation ceramic-on-ceramic total hip arthroplasty at a minimum of ten years.

Cathal J McCarthy1, John Mahon1, Gerard A Sheridan1, Adanna Welch-Phillips1, John M O'Byrne1,2, Paddy J Kenny1,2.   

Abstract

Background: Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years.
Methods: A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively.
Results: There was a 6.2% (n = 28) all-cause and 5.3% (n = 24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months-11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15-95) pre-operatively to a mean of 15.6 (range 0-78) at 10 years.
Conclusion: This study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. Our rates of ceramic fracture were consistent with other studies.
© 2022 Delhi Orthopedic Association. All rights reserved.

Entities:  

Year:  2022        PMID: 35865324      PMCID: PMC9293759          DOI: 10.1016/j.jcot.2022.101942

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  33 in total

1.  Total arthroplasty of the hip by fritted alumina prosthesis. Experimental study and 1st clinical applications.

Authors:  P Boutin
Journal:  Orthop Traumatol Surg Res       Date:  2014-01-20       Impact factor: 2.256

2.  Alumina-on-alumina THA performed in patients younger than 30 years: a 10-year minimum followup study.

Authors:  Hyeong Jo Yoon; Jeong Joon Yoo; Kang Sup Yoon; Kyung-Hoi Koo; Hee Joong Kim
Journal:  Clin Orthop Relat Res       Date:  2012-07-24       Impact factor: 4.176

3.  Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty.

Authors:  Christophe Chevillotte; Vincent Pibarot; Jean-Paul Carret; Jacques Bejui-Hugues; Olivier Guyen
Journal:  Int Orthop       Date:  2010-12-21       Impact factor: 3.075

4.  Significantly Lower Wear of Ceramic-on-Ceramic Bearings Than Metal-on-Highly Cross-Linked Polyethylene Bearings: A 10- to 14-Year Follow-Up Study.

Authors:  Yoshitoshi Higuchi; Yukiharu Hasegawa; Taisuke Seki; Daigo Komatsu; Naoki Ishiguro
Journal:  J Arthroplasty       Date:  2015-12-19       Impact factor: 4.757

5.  Eleven- to 14-year follow-up results of cementless total hip arthroplasty using a third-generation alumina ceramic-on-ceramic bearing.

Authors:  Nobuhiko Sugano; Masaki Takao; Takashi Sakai; Takashi Nishii; Hidenobu Miki; Kenji Ohzono
Journal:  J Arthroplasty       Date:  2011-10-05       Impact factor: 4.757

6.  Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.

Authors:  Y K Lee; Y C Ha; J-I Yoo; W L Jo; K-C Kim; K H Koo
Journal:  Bone Joint J       Date:  2017-06       Impact factor: 5.082

7.  The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty.

Authors:  Christopher A Jarrett; Amar S Ranawat; Matteo Bruzzone; Yossef C Blum; Jose A Rodriguez; Chitranjan S Ranawat
Journal:  J Bone Joint Surg Am       Date:  2009-06       Impact factor: 5.284

8.  Alumina-on-alumina in THA: a multicenter prospective study.

Authors:  Eduardo Garcia-Cimbrelo; Eduardo Garcia-Rey; Antonio Murcia-Mazón; Agustín Blanco-Pozo; Eduardo Martí
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

9.  Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?

Authors:  Henri Migaud; Sophie Putman; Grégory Kern; Ronald Isida; Julien Girard; Nassima Ramdane; Christian P Delaunay; Moussa Hamadouche
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

10.  Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty.

Authors:  Kyung-Hoi Koo; Yong-Chan Ha; Woon Hwa Jung; Sang-Rim Kim; Jeong Joon Yoo; Hee Joong Kim
Journal:  J Bone Joint Surg Am       Date:  2008-02       Impact factor: 5.284