Literature DB >> 15344470

Ideal-observer performance under signal and background uncertainty.

S Park1, M A Kupinski, E Clarkson, H H Barrett.   

Abstract

We use the performance of the Bayesian ideal observer as a figure of merit for hardware optimization because this observer makes optimal use of signal-detection information. Due to the high dimensionality of certain integrals that need to be evaluated, it is difficult to compute the ideal observer test statistic, the likelihood ratio, when background variability is taken into account. Methods have been developed in our laboratory for performing this computation for fixed signals in random backgrounds. In this work, we extend these computational methods to compute the likelihood ratio in the case where both the backgrounds and the signals are random with known statistical properties. We are able to write the likelihood ratio as an integral over possible backgrounds and signals, and we have developed Markov-chain Monte Carlo (MCMC) techniques to estimate these high-dimensional integrals. We can use these results to quantify the degradation of the ideal-observer performance when signal uncertainties are present in addition to the randomness of the backgrounds. For background uncertainty, we use lumpy backgrounds. We present the performance of the ideal observer under various signal-uncertainty paradigms with different parameters of simulated parallel-hole collimator imaging systems. We are interested in any change in the rankings between different imaging systems under signal and background uncertainty compared to the background-uncertainty case. We also compare psychophysical studies to the performance of the ideal observer.

Mesh:

Year:  2003        PMID: 15344470     DOI: 10.1007/978-3-540-45087-0_29

Source DB:  PubMed          Journal:  Inf Process Med Imaging        ISSN: 1011-2499


  13 in total

1.  Channelized-ideal observer using Laguerre-Gauss channels in detection tasks involving non-Gaussian distributed lumpy backgrounds and a Gaussian signal.

Authors:  Subok Park; Harrison H Barrett; Eric Clarkson; Matthew A Kupinski; Kyle J Myers
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-12       Impact factor: 2.129

2.  Virtual assessment of stereoscopic viewing of digital breast tomosynthesis projection images.

Authors:  Gezheng Wen; Ho-Chang Chang; Jacob Reinhold; Joseph Y Lo; Mia K Markey
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-17

3.  Efficiency of the human observer detecting random signals in random backgrounds.

Authors:  Subok Park; Eric Clarkson; Matthew A Kupinski; Harrison H Barrett
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2005-01       Impact factor: 2.129

4.  Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks.

Authors:  Michael Ghaly; Yong Du; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

5.  Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric Frey
Journal:  J Med Imaging (Bellingham)       Date:  2015-01

6.  Approximating the Ideal Observer and Hotelling Observer for Binary Signal Detection Tasks by Use of Supervised Learning Methods.

Authors:  Weimin Zhou; Hua Li; Mark A Anastasio
Journal:  IEEE Trans Med Imaging       Date:  2019-04-15       Impact factor: 10.048

7.  Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

8.  Use of Sub-Ensembles and Multi-Template Observers to Evaluate Detection Task Performance for Data That are Not Multivariate Normal.

Authors:  Xin Li; Abhinav K Jha; Michael Ghaly; Fatma E A Elshahaby; Jonathan M Links; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2016-12-22       Impact factor: 10.048

9.  Toward realistic and practical ideal observer (IO) estimation for the optimization of medical imaging systems.

Authors:  Xin He; Brian S Caffo; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

10.  Optimization of energy window for 90Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model-mismatch.

Authors:  Xing Rong; Michael Ghaly; Eric C Frey
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.