The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements.

Claire L Brockett1, Phil Harper, Sophie Williams, Graham H Isaac, Rob S Dwyer-Joyce, Zhongmin Jin, John Fisher.   

Abstract

Large diameter metal-on-metal bearings (MOM) are becoming increasingly popular, addressing the needs of young and more active patients. Clinical data has shown excellent short-to-mid-term results, though incidences of transient squeaking have been noted between implantation and up to 2 years post-operative. Geometric design features, such as clearance, have been significant in influencing the performance of the bearings. Sets of MOM bearings with different clearances were investigated in this study using a hip friction simulator to examine the influence of clearance on friction, lubrication and squeaking. The friction factor was found to be highest in the largest clearance bearings under all test conditions. The incidence of squeaking was also highest in the large clearance bearings, with all bearings in this group squeaking throughout the study. A very low incidence of squeaking was observed in the other two clearance groups. The measured lubricating film was found to be lowest in the large clearance bearings. This study suggests that increasing the bearing clearance results in reduced lubricant film thickness, increased friction and an increased incidence of squeaking.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17990078     DOI: 10.1007/s10856-007-3298-9

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  17 in total

1.  Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants.

Authors:  Claude B Rieker; Rolf Schön; Reto Konrad; Gernot Liebentritt; Patric Gnepf; Ming Shen; Paul Roberts; Peter Grigoris
Journal:  Orthop Clin North Am       Date:  2005-04       Impact factor: 2.472

2.  Friction of total hip replacements with different bearings and loading conditions.

Authors:  Claire Brockett; Sophie Williams; Zhongmin Jin; Graham Isaac; John Fisher
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-05       Impact factor: 3.368

3.  Surface replacement of the hip joint.

Authors:  S Tanaka
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

4.  Long-term results of low-friction arthroplasty.

Authors:  J Charnley
Journal:  Hip       Date:  1982

5.  Metal on metal surface replacement of the hip. Experience of the McMinn prothesis.

Authors:  D McMinn; R Treacy; K Lin; P Pynsent
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

6.  Surface replacement arthroplasty of the hip.

Authors:  H Wagner
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

7.  A study of implant failure in the Wagner resurfacing arthroplasty.

Authors:  R S Bell; J Schatzker; V L Fornasier; S B Goodman
Journal:  J Bone Joint Surg Am       Date:  1985-10       Impact factor: 5.284

8.  Frictional torque and wear of retrieved hip prostheses: a comparison between alumina/PE and Co-Cr/PE prostheses.

Authors:  Atsushi Kusaba; Yoshikatsu Kuroki; Saiji Kondo; Isao Hirose; Yuichi Ito; Yoshio Shirasaki; Tetsuta Tateishi; Jörg Scholz
Journal:  J Long Term Eff Med Implants       Date:  2002

9.  Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation.

Authors:  William L Walter; Gary C O'toole; William K Walter; Andrew Ellis; Bernard A Zicat
Journal:  J Arthroplasty       Date:  2007-03-28       Impact factor: 4.757

10.  Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis.

Authors:  J Daniel; P B Pynsent; D J W McMinn
Journal:  J Bone Joint Surg Br       Date:  2004-03
View more
  9 in total

1.  Is metal-on-metal squeaking related to acetabular angle of inclination?

Authors:  Thomas Bernasek; David Fisher; David Dalury; Melissa Levering; Kirk Dimitris
Journal:  Clin Orthop Relat Res       Date:  2011-04-22       Impact factor: 4.176

2.  [Squeaking as a cause for revision of a composite ceramic cup].

Authors:  U J Schlegel; N Bishop; R Sobottke; C Perka; P Eysel; M M Morlock
Journal:  Orthopade       Date:  2011-09       Impact factor: 1.087

3.  Squeaking: Current knowledge and how to avoid it.

Authors:  Arjuna M Imbuldeniya; Simon J Pearce; William L Walter; Bernard A Zicat; William K Walter
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

4.  Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.

Authors:  Denis Nam; Toby Barrack; Staci R Johnson; Ryan M Nunley; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

5.  Does diametrical clearance influence the wear of Pinnacle hip implants?

Authors:  Sean Bergiers; Harry Hothi; Johann Henckel; Antti Eskelinen; John Skinner; Alister Hart
Journal:  Bone Joint Res       Date:  2020-08-25       Impact factor: 5.853

6.  Analysis of friction between articular cartilage and polyvinyl alcohol hydrogel artificial cartilage.

Authors:  Feng Li; Anmin Wang; Chengtao Wang
Journal:  J Mater Sci Mater Med       Date:  2016-03-12       Impact factor: 3.896

7.  The damping effect of cement as a potential mitigation factor of squeaking in ceramic-on-ceramic total hip arthroplasty.

Authors:  F J Burgo; D E Mengelle; A Ozols; C Fernandez; C M Autorino
Journal:  Bone Joint Res       Date:  2016-11       Impact factor: 5.853

Review 8.  Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints.

Authors:  Md J Nine; Dipankar Choudhury; Ay Ching Hee; Rajshree Mootanah; Noor Azuan Abu Osman
Journal:  Materials (Basel)       Date:  2014-02-10       Impact factor: 3.623

9.  The Effect of Kinematic Conditions and Synovial Fluid Composition on the Frictional Behaviour of Materials for Artificial Joints.

Authors:  David Nečas; Martin Vrbka; Ivan Křupka; Martin Hartl
Journal:  Materials (Basel)       Date:  2018-05-10       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.