Literature DB >> 17041924

Friction of total hip replacements with different bearings and loading conditions.

Claire Brockett1, Sophie Williams, Zhongmin Jin, Graham Isaac, John Fisher.   

Abstract

Metal-on-ultra-high molecular weight polyethylene (UHMWPE) total hip replacements have been the most popular and clinically successful implants to date. However, it is well documented that the wear debris from these prostheses contributes to osteolysis and ultimate failure of the prosthesis, hence alternative materials have been sought. A range of 28 mm diameter bearings were investigated using a hip friction simulator, including conventional material combinations such as metal-on-UHWMPE, ceramic-on-ceramic (CoC), and metal-on-metal (MoM), as well as novel ceramic-on-metal (CoM) pairings. Studies were performed under different swing-phase load and lubricant conditions. The friction factors were lowest in the ceramic bearings, with the CoC bearing having the lowest friction factor in all conditions. CoM bearings also had low friction factors compared with MoM, and the trends were similar to CoC bearings for all test conditions. Increasing swing phase load was shown to cause an increase in friction factor in all tests. Increased serum concentration resulted in increased friction factor in all material combinations, except MoM, where increased serum concentration produced a significant reduction in friction factor.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17041924     DOI: 10.1002/jbm.b.30691

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  26 in total

1.  Effect of protein concentrations of bovine serum albumin and γ-globulin on the frictional response of a cobalt-chromium femoral head.

Authors:  Cong-Truyen Duong; Jae-Hoon Lee; Younho Cho; Ju-Suk Nam; Hyong-Nyun Kim; Sang-Soo Lee; Seonghun Park
Journal:  J Mater Sci Mater Med       Date:  2012-03-10       Impact factor: 3.896

2.  Hard-on-hard total hip impingement causes extreme contact stress concentrations.

Authors:  Jacob M Elkins; Megan K O'Brien; Nicholas J Stroud; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

3.  The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements.

Authors:  Claire L Brockett; Phil Harper; Sophie Williams; Graham H Isaac; Rob S Dwyer-Joyce; Zhongmin Jin; John Fisher
Journal:  J Mater Sci Mater Med       Date:  2007-11-08       Impact factor: 3.896

4.  Hierarchy of stability factors in reverse shoulder arthroplasty.

Authors:  Sergio Gutiérrez; Tony S Keller; Jonathan C Levy; William E Lee; Zong-Ping Luo
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

5.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

6.  Edge-loading severity as a function of cup lip radius in metal-on-metal total hips--a finite element analysis.

Authors:  Jacob M Elkins; Karen M Kruger; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-08-02       Impact factor: 3.494

7.  Bone-on-bone versus hardware impingement in total hips: a biomechanical study.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2012

8.  The 2014 Frank Stinchfield Award: The 'landing zone' for wear and stability in total hip arthroplasty is smaller than we thought: a computational analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

Review 9.  Biotribology of artificial hip joints.

Authors:  Francesca Di Puccio; Lorenza Mattei
Journal:  World J Orthop       Date:  2015-01-18

10.  Do obesity and/or stripe wear increase ceramic liner fracture risk? An XFEM analysis.

Authors:  Jacob M Elkins; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

View more