Literature DB >> 17562404

Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation.

William L Walter1, Gary C O'toole, William K Walter, Andrew Ellis, Bernard A Zicat.   

Abstract

Audible squeaking in total hip replacements with ceramic-on-ceramic bearings is a rare problem. Acetabular component orientation was compared for 17 squeaking hips and 17 matched controls. Ninety-four percent of control hips were in a range of 25 degrees +/- 10 degrees anteversion and 45 degrees +/- 10 degrees inclination, but only 35% of squeaking hips were in this range (P = .0003). Eight hips squeak with bending. Four hips squeak with walking, and 5 hips squeak after prolonged periods of walking. Hips that squeaked with walking had acetabular components that were more anteverted (40 degrees ) than hips that squeaked with bending (19 degrees ) (P = .001) or prolonged walking (18 degrees ) (P = .020). The hips started squeaking after an average of 14 months. Patients with squeaking hips were younger, heavier, and taller than patients with silent hips.

Entities:  

Mesh:

Year:  2007        PMID: 17562404     DOI: 10.1016/j.arth.2006.06.018

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  67 in total

1.  A squeaky reputation: the problem may be design-dependent.

Authors:  Javad Parvizi; Bahar Adeli; Justin C Wong; Camilo Restrepo; Richard H Rothman
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

2.  Is metal-on-metal squeaking related to acetabular angle of inclination?

Authors:  Thomas Bernasek; David Fisher; David Dalury; Melissa Levering; Kirk Dimitris
Journal:  Clin Orthop Relat Res       Date:  2011-04-22       Impact factor: 4.176

3.  Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

Authors:  Jerome Hausselle; Pierre Etienne Moreau; Loic Wessely; Emmanuel de Thomasson; Ayman Assi; Sebastien Parratte; Jerome Essig; Wafa Skalli
Journal:  Int Orthop       Date:  2012-03-21       Impact factor: 3.075

4.  [Squeaking as a cause for revision of a composite ceramic cup].

Authors:  U J Schlegel; N Bishop; R Sobottke; C Perka; P Eysel; M M Morlock
Journal:  Orthopade       Date:  2011-09       Impact factor: 1.087

5.  The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements.

Authors:  Claire L Brockett; Phil Harper; Sophie Williams; Graham H Isaac; Rob S Dwyer-Joyce; Zhongmin Jin; John Fisher
Journal:  J Mater Sci Mater Med       Date:  2007-11-08       Impact factor: 3.896

6.  High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings.

Authors:  J C Keurentjes; R M Kuipers; D J Wever; B W Schreurs
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

7.  Squeaking hips.

Authors:  William L Walter; Tim S Waters; Mark Gillies; Shane Donohoo; Steven M Kurtz; Amar S Ranawat; William J Hozack; Michael A Tuke
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

8.  Squeaking: Current knowledge and how to avoid it.

Authors:  Arjuna M Imbuldeniya; Simon J Pearce; William L Walter; Bernard A Zicat; William K Walter
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

9.  The 2009 Frank Stinchfield Award: "Hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces.

Authors:  Christophe Chevillotte; Robert T Trousdale; Qingshan Chen; Olivier Guyen; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2009-06-19       Impact factor: 4.176

10.  Incidence of 'squeaking' after ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Christopher Verioti; Kace A Ezzet; Steven N Copp; Richard H Walker; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.