Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants.

Mitsuru Motoyoshi1, Tohru Yoshida, Akiko Ono, Noriyoshi Shimizu.   

Abstract

PURPOSE: To examine the relationship between cortical bone thickness, inter-root distance (horizontal space), distance from alveolar crest to the bottom of maxillary sinus (vertical space) at the prepared site, and implant placement torque and the success rate of mini-implants placed for orthodontic anchorage.
MATERIALS AND METHODS: After computerized tomography examination, mini-implants 1.6 mm wide and 8 mm long were placed in the posterior alveolar bone. The mini-implant was judged a success when orthodontic force could be applied for at least 6 months without pain or clinically detectable mobility. The unpaired t test was performed to examine differences between the success and failure groups. The chi-square analysis or Fisher exact probability test was used to compare the implant success according to placement torque, location, and patient gender. P values less than .05 were considered significant.
RESULTS: The subjects included 4 males (11 implants) and 28 females (76 implants) who ranged in age from 14.6 to 42.8 years. The success rate of the 87 implants was 87.4%. Cortical bone thickness was significantly greater in the success group (1.42 +/- 0.59 mm vs 0.97 +/- 0.31 mm, P = .015). The success rate was significantly higher in the group with an implant placement torque of 8 to 10 Ncm (100%) as compared to implants with higher or lower placement torques. The odds ratio for failure of the mini-implant was 6.93 (P = .047) when the cortical bone thickness was less than 1.0 mm relative to 1.0 mm or more.
CONCLUSION: A relationship between stability after implant placement and the width and height of the peri-implant bone was not demonstrated. The prepared site should have a cortical bone thickness of at least 1.0 mm, and the placement torque should be controlled up to 10 Ncm.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17974113

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  52 in total

1.  Surface characteristics and mechanical behavior of retrieved orthodontic microimplants.

Authors:  Lu Lu; Hyo-Sang Park
Journal:  J Zhejiang Univ Sci B       Date:  2018-05       Impact factor: 3.066

2.  Evaluating miniscrew position using orthopantomograms compared to cone-beam computed tomography.

Authors:  Ruth Bennemann; Martin Baxmann; Ludger Keilig; Susanne Reimann; Bert Braumann; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2012-05-12       Impact factor: 1.938

3.  Does Change in Thread Shape Influence the Pull Out Strength of Mini Implants? An In vitro Study.

Authors:  Aniruddh V Yashwant; S Dilip; R Krishnaraj; K Ravi
Journal:  J Clin Diagn Res       Date:  2017-05-01

4.  Accuracy of torque-limiting devices used for mini-implant placement--an in vitro study.

Authors:  Alexander Pauls; Manuel Nienkemper; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

5.  Assessment of damping capacity as an index of root proximity in self-drilling orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Yasuki Uchida; Miho Matsuoka; Mizuki Inaba; Hiroaki Iwai; Yoko Karasawa; Noriyoshi Shimizu
Journal:  Clin Oral Investig       Date:  2013-03-22       Impact factor: 3.573

6.  Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement.

Authors:  Hong Zhao; Xiao-Ming Gu; Hong-Chen Liu; Zhao-Wu Wang; Chun-Lei Xun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

7.  Buccal cortical bone thickness at miniscrew placement sites in patients with different vertical skeletal patterns.

Authors:  Ilknur Veli; Tancan Uysal; Asli Baysal; Irfan Karadede
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

8.  Influence of geometric design characteristics on primary stability of orthodontic miniscrews.

Authors:  Eman Saad Radwan; Mona A Montasser; Ahmed Maher
Journal:  J Orofac Orthop       Date:  2018-04-10       Impact factor: 1.938

9.  Root proximity of miniscrews at a variety of maxillary and mandibular buccal sites: Reliability of panoramic radiography.

Authors:  Jae-Hwa An; Yong-Il Kim; Seong-Sik Kim; Soo-Byung Park; Woo-Sung Son; Sung-Hun Kim
Journal:  Angle Orthod       Date:  2019-03-11       Impact factor: 2.079

10.  Determination of the dynamics of healing at the tissue-implant interface by means of microcomputed tomography and functional apparent moduli.

Authors:  Po-Chun Chang; Yang-Jo Seol; Steven A Goldstein; William V Giannobile
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Jan-Feb       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.